The synergetic particles collection in three different wet flue gas desulfurization towers: A pilot-scale experimental investigation

被引:29
|
作者
Chen, Zhen [1 ]
You, Changfu [1 ]
Liu, Hanzi [1 ]
Wang, Haiming [1 ]
机构
[1] Tsinghua Univ, Dept Energy & Power Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Flue gas purification; Scrubbing tower; Synergetic particles removal; Bubble flow; Internals; FIRED POWER-PLANT; REMOVAL EFFICIENCY; SCRUBBER; COAL; PERFORMANCE; EMISSION; COLUMN; GASIFICATION; SYSTEMS; FGD;
D O I
10.1016/j.fuproc.2018.07.025
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The synergetic removal of particulate matters (PM) in different wet flue gas desulfurization (WFGD) towers was investigated on a pilot-scale experimental setup with the gas flow up to 6372 m(3)/h. Three types of scrubbing tower, i.e. open scrubbing tower (OST), scrubbing tower with porous tray (TST), and scrubbing tower with a flow pattern control device (FST) were used in this study. The multiphase flow is a counter-current liquid-dispersed flow in OST, while it is an insufficient developed and fully developed bubble flow in TST and FST, respectively. The PM collection efficiency was significantly increased after adding internals (porous tray or flow pattern control device). The total collection efficiency for TST and FST was similar to 84.3% and similar to 87.2%, respectively, when using gypsum slurry as recycle liquid at a superficial gas velocity of 3 m/s and L/G = 10 L/m(3). Comparing to that of OST, the improvement of the efficiency was similar to 9.2% and similar to 13% for TST and FST, respectively. Interestingly, even though the pressure drop of FST is lower than that of TST, the particle removal efficiency of FST is the highest among three scrubbing towers, which means FST is much more cost-effective. The performance index (P1) is introduced in this study to evaluate the particle removal effect of different internals. The P1 for FST is approximately 4 times larger than that of TST at L/G = 10 L/m(3), indicating a much better effect of FST for WFGD, especially for low-load operation in power plant.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 32 条
  • [1] A pilot-scale jet bubbling reactor for wet flue gas desulfurization with pyrolusite
    Su, SJ
    Zhu, XF
    Liu, YJ
    Jiang, WJ
    Jin, Y
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2005, 17 (05) : 827 - 831
  • [3] Experimental investigation of a pilot-scale jet bubbling reactor for wet flue gas desulphurisation
    Zheng, YJ
    Kiil, S
    Johnsson, JE
    CHEMICAL ENGINEERING SCIENCE, 2003, 58 (20) : 4695 - 4703
  • [4] Experimental investigation and modeling of a wet flue gas desulfurization pilot plant
    Kiil, Soren
    Michelsen, Michael L.
    Dam-Johansen, Kim
    Industrial and Engineering Chemistry Research, 1998, 37 (07): : 2792 - 2806
  • [5] Experimental investigation and modeling of a wet flue gas desulfurization pilot plant
    Kiil, S
    Michelsen, ML
    Dam-Johansen, K
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1998, 37 (07) : 2792 - 2806
  • [6] The effect of selective limestone characteristics on reagent performance in a pilot-scale wet flue gas desulfurization facility
    Miller, SF
    DiGnazio, F
    Scaroni, AW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U773 - U773
  • [7] Pilot-scale experiment and simulation optimization of dual-loop wet flue gas desulfurization spray scrubbers
    Qin, Mingchen
    Dong, Yong
    Cui, Lin
    Yao, Junwen
    Ma, Chunyuan
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 148 : 280 - 290
  • [8] A Study of Experimental and Improved Absorption Model for the Spray Towers of Wet Flue Gas Desulfurization
    Liu Dingping
    Yu Hailong
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 574 - 579
  • [9] Experimental study on the synergetic removal of fine particles by wet flue gas desulfurization tower with a flow pattern control device
    Chen, Zhen
    You, Changfu
    Wang, Haiming
    Liu, Qingxia
    POWDER TECHNOLOGY, 2019, 343 : 122 - 128
  • [10] Emission Characteristics of Fine Particles from Wet Flue Gas Desulfurization System Using a Cascade of Double Towers
    Liu, Songtao
    Yang, Haikuan
    Zhang, Zhibo
    Chen, Jianmeng
    Chen, Chuanmin
    Guo, Tianxiang
    Cao, Yue
    Jia, Wenbo
    AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (07) : 1901 - 1909