Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector

被引:8
|
作者
Dulski, K. [1 ]
Zgardzinska, B. [2 ]
Bialas, P. [1 ]
Curceanu, C. [3 ]
Czerwinski, E. [1 ]
Gajos, A. [1 ]
Glowacz, B. [1 ]
Gorgol, M. [2 ]
Hiesmayr, B. C. [4 ]
Jasinska, B. [2 ]
Kisielewska-Kaminska, D. [1 ]
Korcyl, G. [1 ]
Kowalski, P. [5 ]
Kozik, T. [1 ]
Krawczyk, N. [1 ]
Krzemien, W. [6 ]
Kubicz, E. [1 ]
Mohammed, Muhsin [1 ,7 ]
Pawlik-Niedzwiecka, M. [1 ]
Niedzwiecki, S. [1 ]
Palka, M. [1 ]
Raczynski, L. [5 ]
Raj, J. [1 ]
Rudy, Z. [1 ]
Sharma, N. G. [1 ]
Sharma, S. [1 ]
Shivani, Shivani [1 ]
Shopa, R. Y. [5 ]
Silarski, M. [1 ]
Skurzok, M. [1 ]
Wieczorek, A. [1 ]
Wislicki, W. [5 ]
Zielinski, M. [1 ]
Moskal, P. [1 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, PL-30348 Krakow, Poland
[2] Marie Curie Sklodowska Univ, Inst Phys, PL-20031 Lublin, Poland
[3] INFN, Lab Nazl Frascati, I-00044 Frascati, Italy
[4] Univ Vienna, Fac Phys, A-1090 Vienna, Austria
[5] Natl Ctr Nucl Res, Dept Complex Syst, PL-05400 Otwock, Poland
[6] Natl Ctr Nucl Res, High Energy Phys Div, PL-05400 Otwock, Poland
[7] Univ Mosul, Dept Phys, Coll Educ Pure Sci, Mosul, Iraq
基金
奥地利科学基金会;
关键词
PLASTIC SCINTILLATOR; ANNIHILATION;
D O I
10.12693/APhysPolA.132.1637
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
引用
收藏
页码:1637 / 1640
页数:4
相关论文
共 50 条
  • [1] Tests of discrete symmetries in positronium decays with the J-PET detector
    Czerwinski, E.
    6TH SYMPOSIUM ON PROSPECTS IN THE PHYSICS OF DISCRETE SYMMETRIES - DISCRETE 2018, 2020, 1586
  • [2] Tests of discrete symmetries in positronium decays with the J-PET detector
    Silarski, Michal
    MESON 2018 - 15TH INTERNATIONAL WORKSHOP ON MESON PHYSICS, 2019, 199
  • [3] CPT symmetry test in positronium annihilations with the J-PET detector
    Chug, N.
    Gajos, A.
    PARTICLES AND NUCLEI INTERNATIONAL CONFERENCE 2021, PANIC2021, 2021,
  • [4] COMMISSIONING OF THE J-PET DETECTOR FOR STUDIES OF DECAYS OF POSITRONIUM ATOMS
    Czerwinski, E.
    Dulski, K.
    Bialas, P.
    Curceanu, C.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Raczynski, L.
    Rudy, Z.
    Sharma, N. G.
    Sharma, S.
    Shopa, R. Y.
    Silarski, M.
    Skurzok, M.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1961 - 1968
  • [5] FEASIBILITY OF ORTHO-POSITRONIUM LIFETIME STUDIES WITH THE J-PET DETECTOR IN CONTEXT OF MIRROR MATTER MODELS
    Krzemien, Wojciech
    del Rio, Elena Perez
    Kacprzak, Krzysztof
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 165 - 174
  • [6] Sensitivity of Discrete Symmetry Tests in the Positronium System with the J-PET Detector
    Gajos, Aleksander
    SYMMETRY-BASEL, 2020, 12 (08):
  • [7] A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
    Mohammed, Muhsin
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Sharma, N. G.
    Sharma, S.
    Shivani
    Skurzok, M.
    Silarski, M.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    ACTA PHYSICA POLONICA A, 2017, 132 (05) : 1486 - 1489
  • [8] Status and Prospects of Discrete Symmetries Tests in Positronium Decays with the J-PET Detector
    Silarski, M.
    18TH INTERNATIONAL CONFERENCE ON POSITRON ANNIHILATION (ICPA-18), 2019, 2182
  • [10] Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
    K. Dulski
    C. Curceanu
    E. Czerwiński
    A. Gajos
    M. Gorgol
    N. Gupta-Sharma
    B. C. Hiesmayr
    B. Jasińska
    K. Kacprzak
    Ł. Kapłon
    D. Kisielewska
    K. Klimaszewski
    G. Korcyl
    P. Kowalski
    N. Krawczyk
    W. Krzemień
    T. Kozik
    E. Kubicz
    M. Mohammed
    Sz. Niedźwiecki
    M. Pałka
    M. Pawlik-Niedźwiecka
    L. Raczyński
    J. Raj
    K. Rakoczy
    Z. Rudy
    S. Sharma
    R. Y. Shivani
    M. Shopa
    M. Silarski
    W. Skurzok
    B. Wiślicki
    P. Zgardzińska
    Hyperfine Interactions, 2018, 239