Efficiency of a cubic NaI(Tl) detector with rectangular cavity using standard radioactive point sources placed at non-axial position

被引:32
|
作者
Abbas, Mahmoud, I [1 ]
Badawi, Mohamed S. [2 ]
Thabet, Abouzeid A. [3 ]
Kopatch, Yu N. [4 ]
Ruskov, Ivan N. [4 ,5 ]
Grozdanov, D. N. [4 ,5 ]
Noureddine, Salam [6 ]
Fedorov, N. A. [4 ,7 ]
Gouda, Mona M. [1 ]
Hramco, C. [4 ,8 ]
Abd-Elzaher, Mohamed [9 ]
Hamzawy, A. [10 ]
Elsafi, Mohamed [1 ]
El-Khatib, Ahmed M. [1 ]
机构
[1] Alexandria Univ, Fac Sci, Phys Dept, Alexandria 21511, Egypt
[2] Beirut Arab Univ, Fac Sci, Phys Dept, Beirut, Lebanon
[3] Pharos Univ Alexandria, Fac Allied Med Sci, Dept Med Equipment Technol, Alexandria, Egypt
[4] Joint Inst Nucl Res JINR, Dubna, Russia
[5] BAS, Inst Nucl Res & Nucl Energy INRNE, Sofia, Bulgaria
[6] Lebanese Univ, Fac Sci, Phys Dept, Beirut, Lebanon
[7] Lomonosov Moscow State Univ MSU, Fac Phys, Moscow, Russia
[8] Moldavian Acad Sci, Inst Chem, Kishinev, Moldova
[9] Arab Acad Sci Technol & Maritime Transport, Fac Engn, Dept Basic & Appl Sci, Alexandria, Egypt
[10] Umm Al Qura Univ, Al Jamoum Univ Coll, Phys Dept, Al Jamoum, Saudi Arabia
关键词
Cubic detector; Geant4; simulation; Efficiency transfer; Effective solid angle and full-energy peak efficiency; ENERGY PEAK EFFICIENCY; MATHEMATICAL-METHOD; CALCULATE;
D O I
10.1016/j.apradiso.2020.109139
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Low cost scintillation detectors as compared with HPGe detectors are considered to be one of most important radiation detection tools. Therefore, these detectors can be manufactured in different shapes and work at room temperature without any cooling systems, which added an extra advantage to it. This work presents a study of a cubic detector with a rectangular cavity in different experimental setup geometries, using standard point-like gamma-ray sources, where the efficiency of the detector in these geometries was the target to be studied. According to this aim, the data from the experimental measurements was used to determine the detector efficiency. An analytical calculation of the detector efficiency was done by using a new mathematical expression, this mathematical expression depends on the efficiency transfer technique and effective solid angle calculations. To support the mathematical model, the source-to-detector arrangement was simulated by Geant4 Monte Carlo code. All the compared efficiency results were found to be promising and trusted based on the calculated deviation percentages.
引用
收藏
页数:10
相关论文
共 18 条
  • [1] New numerical simulation method to calibrate the regular hexagonal NaI(Tl) detector with radioactive point sources situated non-axial
    Hamzawy, Ayman
    Grozdanov, Dimitar N.
    Badawi, Mohamed S.
    Aliyev, Fuad A.
    Thabet, Abouzeid A.
    Abbas, Mahmoud I.
    Ruskov, Ivan N.
    El-Khatib, Ahmed M.
    Kopatch, Yuri N.
    Gouda, Mona M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [2] Characterization of the efficiency of a cubic NaI detector with rectangular cavity for axially positioned sources
    Badawi, M. S.
    Noureddine, S.
    Kopatch, Y. N.
    Abbas, M., I
    Ruskov, I. N.
    Grozdanov, D. N.
    Thabet, A. A.
    Fedorov, N. A.
    Gouda, M. M.
    Hramco, C.
    Abd-Elzaher, M.
    Hamzawy, A.
    Elsafi, M.
    El-Khatib, A. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02)
  • [3] NaI(Tl) Detector Efficiency Computation Using Radioactive Parallelepiped Sources Based on Efficiency Transfer Principle
    Badawi, Mohamed S.
    Gouda, Mona M.
    El-Khatib, Ahmed M.
    Thabet, Abouzeid A.
    Salim, Ahmed A.
    Abbas, Mahmoud I.
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2015, 2015
  • [4] Well-type NaI(Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity
    El-Khatib, Ahmed M.
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    Jovanovic, Slobodan I.
    Gouda, Mona M.
    Mohamed, Moustafa M.
    Dlabac, Aleksandar D.
    Abd-Elzaher, Mohamed
    Mihaljevic, Nikola N.
    Abbas, Mahmoud I.
    CHINESE JOURNAL OF PHYSICS, 2016, 54 (03) : 338 - 346
  • [5] New numerical simulation approach to calibrate the NaI(Tl) detectors array using non-axial extended spherical sources
    Badawi, M. S.
    El-Khatib, A. M.
    Krar, M. E.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [6] EFFICIENCY VARIATIONS OF CYLINDRICAL DETECTORS FOR NON-AXIAL POINT-SOURCES
    KAPLANIS, SN
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (9-10): : 543 - 544
  • [7] CALIBRATION OF NaI (Tl) CYLINDRICAL DETECTOR USING AXIALLY SHIFTED RADIOACTIVE CYLINDRICAL SOURCES
    Gouda, Mona M.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2019, 34 (04): : 353 - 360
  • [8] Calibration of Cylindrical NaI(Tl) Detector Using Different Perpendicular Radioactive Cylindrical Sources
    Badawi, Mohamed. S.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (04): : 67 - 75
  • [9] Calibration of well-type NaI(Tl) detector using a point sources measured out the detector well at different axial distances
    Gouda, M. M.
    Badawi, M. S.
    El-Khatib, A. M.
    Mohamed, M. M.
    Thabet, A. A.
    Abbas, M. I.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [10] CALCULATION OF NaI(Tl) DETECTOR FULL-ENERGY PEAK EFFICIENCY USING THE EFFICIENCY TRANSFER METHOD FOR SMALL RADIOACTIVE CYLINDRICAL SOURCES
    Gouda, Mona M.
    Badawi, Mohamed S.
    EL-Khatib, Ahmed M.
    Hussien, Nancy S.
    Abbas, Mahmoud I.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2016, 31 (02): : 150 - 158