Myopic deconvolution of adaptive optics retina images

被引:1
|
作者
Blanco, L. [1 ,2 ]
Mugnier, L. M. [1 ]
Glanc, M. [2 ]
机构
[1] Off Natl Etud & Rech Aerosp, Dept Opt, BP 72, F-92322 Chatillon, France
[2] Observ Paris, Lab Etudes Spatiales Instrumentat Astrophysique, F-92195 Meudon, France
关键词
Retinal imaging; myopic deconvolution; adaptive optics; unsupervised estimation; inverse problems; RESTORATION;
D O I
10.1117/12.873739
中图分类号
TH742 [显微镜];
学科分类号
摘要
Adaptive Optics corrected flood imaging of the retina is a well-developed technique. The raw images are usually of poor contrast because they are dominated by an important background, and because AO correction is only partial. Interpretation of such images is difficult without an appropriate post-processing, typically background subtraction and image deconvolution. Deconvolution is difficult because the PSF is not well-known, which calls for myopic/blind deconvolution, and because the image contains in-focus and out-of-focus information from the object. In this communication, we tackle the deconvolution problem. We model the 3D imaging by assuming that the object is approximately the same in all planes within the depth of focus. The 3D model becomes a 2D model with the global PSF being an unknown linear combination of the PSF for each plane. The problem is to estimate the coefficients of this combination and the object. We show that the traditional method of joint estimation fails even for a small number of coefficients. We derive a marginal estimation of unknown hyperparameters (PSF coefficients, object Power Spectral Density and noise level) followed by a MAP estimation of the object. Such a marginal estimation has better statistical convergence properties, and allows us to obtain an "unsupervised" estimate of the object. Results on simulated and experimental data are shown.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Myopic deconvolution method for adaptive optics images of stellar fields
    Fusco, T
    Véran, JP
    Conan, JM
    Mugnier, LM
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1999, 134 (01): : 193 - 200
  • [2] Deconvolution of astronomical adaptive optics images
    Fusco, T
    Mugnier, L
    Conan, JM
    Rousset, G
    Marchis, F
    Chauvin, G
    Lagrange, AK
    Mouillet, D
    ASTRONOMY WITH HIGH CONTRAST IMAGING: FROM PLANETARY SYSTEMS TO ACTIVE GALACTIC NUCLEI, 2003, 8 : 259 - 271
  • [3] Anisoplanatic deconvolution of adaptive optics images
    Flicker, RC
    Rigaut, FJ
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (03) : 504 - 513
  • [4] Deconvolution of adaptive optics retinal images
    Christou, JC
    Roorda, A
    Williams, DR
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2004, 21 (08) : 1393 - 1401
  • [5] An ADMM-LAP method for total variation myopic deconvolution of adaptive optics retinal images
    Chen, Xiaotong
    Herring, James L.
    Nagy, James G.
    Xi, Yuanzhe
    Yu, Bo
    INVERSE PROBLEMS, 2021, 37 (01)
  • [6] Marginalized myopic deconvolution of adaptive optics corrected images using Markov chain Monte Carlo methods
    Yan, Alix
    Mugnier, Laurent M.
    Giovannelli, Jean-Francois
    Fetick, Romain
    Petit, Cyril
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2023, 9 (04)
  • [7] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra
    Conan, Jean-Marc
    Mugnier, Laurent M.
    Fusco, Thierry
    Michau, Vincent
    Rousset, Gérard
    Applied Optics, 1998, 37 (21): : 4614 - 4622
  • [8] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra
    Conan, JM
    Mugnier, LM
    Fusco, T
    Michau, V
    Rousset, G
    APPLIED OPTICS, 1998, 37 (21): : 4614 - 4622
  • [9] Iterative blind deconvolution of adaptive optics images
    梁莹
    饶长辉
    李梅
    耿则勋
    ChineseOpticsLetters, 2006, (04) : 187 - 188
  • [10] Myopic deconvolution of adaptive optics images by use of object and point-spread function power spectra: comment
    Kopeika, NS
    APPLIED OPTICS, 2000, 39 (15) : 2412 - 2414