A novel signal-averaged electrocardiogram and an ambulatory-based signal-averaged electrocardiogram show strong correlations with conventional signal-averaged electrocardiogram in healthy subjects: A validation study

被引:6
|
作者
Hashimoto, Kenichi [1 ]
Takase, Bonpei [1 ]
Nagashima, Masaaki [2 ]
Kasamaki, Yuji [3 ]
Shimabukuro, Hiroaki [4 ]
Soma, Masayoshi [5 ]
Nakayama, Tomohiro [2 ]
机构
[1] Natl Def Med Coll, Dept Intens Care Med, Tokorozawa, Saitama, Japan
[2] Nihon Univ, Div Lab Med, Dept Pathol & Microbiol, Sch Med, Tokyo, Japan
[3] Kanazawa Med Univ, Dept Gen Med, Himi Municipal Hosp, Kanazawa, Ishikawa, Japan
[4] Nihon Univ, Itabashi Hosp, Dept Clin Lab, Tokyo, Japan
[5] Nihon Univ, Sch Med, Dept Med, Div Gen Med, Tokyo, Japan
关键词
Sudden cardiac death; Ventricular tachycardia; Lethal arrhythmia; Holter electrocardiogram; Late potential; TIME-DOMAIN ANALYSIS; NONSUSTAINED VENTRICULAR-TACHYCARDIA; LATE POTENTIALS; MYOCARDIAL-INFARCTION; IDENTIFYING PATIENTS; BRUGADA-SYNDROME; HIGH-RESOLUTION; DILATED CARDIOMYOPATHY; ARRHYTHMIC EVENTS; SUDDEN-DEATH;
D O I
10.1016/j.jelectrocard.2018.10.084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A novel signal-averaged electrocardiogram (SAECG) device and a novel ambulatory SAECG device are clinically available, but reference values have not been established. This study aimed to validate the novel SAECG and the novel ambulatory-based SAECG devices by comparison with the conventional SAECG device. Methods and results: High-resolution SAECGs were recorded consecutively in 83 healthy volunteers using the 3 devices. A novel ambulatory SAECG device was used as real-time recording within 15 min for validation study (15 min ambulatory-based SAECG). We examined the concordance of positive results (at least 2/3 abnormal SAECG parameters) and negative results (0 or 1/3 abnormal parameters), as well as the correlations between SAECG parameters (filtered QRS duration [fQRS]); duration of low-amplitude signals < 40 mu V in the terminal filtered QRS complex LAS(40)]; root mean square voltage of the terminal 40 ms of the filtered QRS complex [RMS40]). Qualitative analysis showed excellent concordance among the novel SAECG, the 15 min ambulatory-based SAECG, and the conventional SAECG methods (novel SAECG vs. conventional SAECG = 94%; 15 min ambulatory-based SAECG vs. conventional SAECG = 91.6%; p = 0.755), while quantitative analysis indicated strong correlations between the novel SAECG and the conventional SAECG values for fQRS, LAS(40), and LnRMS(40), (r = 0.838-0.805, p < 0.0001, respectively). Strong correlations were also seen between 15 min ambulatory-based SAECG and conventional SAECG values for fQRS, LAS(40), and RMS40 (r = 0.943-0.888, p < 0.0001, respectively). However, Bland-Altman quantitative analysis showed better agreement in fQRS and LnRMS(40) measured by the 15 min ambulatory-based SAECG and the conventional SAECG than those by the novel SAECG and the conventional SAECG (fQRS, Lin's rho_c = 0.923 vs. 0757; RMS40, Lin's rho_c = 0.932 vs. 0.818, respectively). Conclusion: In healthy subjects, the parameters of either the novel SAECG or the 15 min ambulatory-based SAECG and those of the conventional SAECG were strongly correlated. Relatively good agreements were observed among 3 SAECGs, especially better between the 15 min ambulatory-based SAECG and the conventional SAECG probably due to similar measurement system of 2 methods. (C) 2018 Published by Elsevier Inc.
引用
收藏
页码:1145 / 1152
页数:8
相关论文
共 50 条
  • [1] REPRODUCIBILITY OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    ENGEL, TR
    PIERCE, DL
    PATIL, KD
    AMERICAN HEART JOURNAL, 1991, 122 (06) : 1652 - 1660
  • [2] Effect of hemodialysis on the signal-averaged electrocardiogram
    Girgis, I
    Contreras, G
    Chakko, S
    Perez, G
    McLoughlin, J
    Lafferty, J
    Gualberti, L
    Ammazzalorso, M
    Constantino, T
    Bresznyak, ML
    Kleiner, M
    McGinn, TG
    Myerburg, RJ
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 34 (06) : 1105 - 1113
  • [3] THE SIGNAL-AVERAGED ELECTROCARDIOGRAM IN DIABETIC CHILDREN
    CELIKER, A
    AKINCI, A
    OZIN, B
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1994, 44 (03) : 271 - 274
  • [4] Reproducibility of the signal-averaged electrocardiogram.
    Copie, X
    Blankoff, I
    Fei, L
    Murgatroyd, FD
    Hnatkova, K
    Malik, M
    Camm, AJ
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1996, 89 (03): : 325 - 330
  • [5] REPRODUCIBILITY OF DATA OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    GOEDELMEINEN, L
    HOFMANN, M
    SCHMIDT, G
    HOGLSPERGER, H
    JAHNS, G
    BAEDEKER, W
    BLOMER, H
    CIRCULATION, 1987, 76 (04) : 31 - 31
  • [6] Effects of exercise on signal-averaged electrocardiogram
    Beauregard, LAM
    Volosin, KJ
    Askenase, AD
    Waxman, HL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (02): : 215 - 221
  • [7] ALTERATIONS IN THE SIGNAL-AVERAGED ELECTROCARDIOGRAM WITH ISCHEMIA
    CRUMP, R
    SHANDLING, A
    SWITZENBERG, S
    MYRIANTHEFS, M
    NOLASCO, V
    ELLESTAD, M
    CLINICAL RESEARCH, 1994, 42 (01): : A71 - A71
  • [8] CURRENT USEFULNESS OF THE SIGNAL-AVERAGED ELECTROCARDIOGRAM
    KJELLGREN, O
    GOMES, JA
    CURRENT PROBLEMS IN CARDIOLOGY, 1993, 18 (06) : 361 - +
  • [9] Short-, mid-, and long-term reproducibility of the atrial signal-averaged electrocardiogram in healthy subjects: Comparison with the conventional ventricular signal-averaged electrocardiogram
    Savelieva, I
    Aytemir, K
    Hnatkova, K
    Camm, AJ
    Malik, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (01): : 122 - 127
  • [10] THE EFFECTS OF SMOKING ON THE SIGNAL-AVERAGED ELECTROCARDIOGRAM IN NORMAL SUBJECTS
    SPERRY, RE
    VACEK, JL
    SMITH, GS
    CHEST, 1991, 99 (01) : 121 - 122