Post-test analyses of LIFUS5 Test#3 experiment

被引:13
|
作者
Eboli, Marica [1 ]
Del Nevo, Alessandro [2 ]
Forgione, Nicola [1 ]
Porfiri, Maria Teresa [3 ]
机构
[1] Univ Pisa, DICI, Largo Lucia Lazzarino 2, I-56122 Pisa, Italy
[2] ENEA FSN ING PAN, CR Brasimone, I-40032 Bologna, Italy
[3] ENEA FSN FUSTEC TEN, Via E Fermi 45, I-00044 Frascati, Italy
关键词
Water; Lithium-lead; SIMMER; Chemical reaction; WCLL breeding blanket; Safety;
D O I
10.1016/j.fusengdes.2017.03.046
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The interaction between lithium-lead and water is a major concern of Water Cooled Lithium Lead (WCLL) breeding blanket design concept, therefore deterministic safety analysis of the in-box LOCA postulated accident is of primary importance. The paper presents the preliminary code assessment process of the modified version of SIMMER-Ill code for fusion application by means of LIFUS5 Test#3 post-test analyses. A series of sensitivity calculations are performed to overcome uncertainties in the test data and experiment execution, and to investigate the capability of the code in predicting the phenomena occurring during MI/water interaction. Results show agreement between numerical results and experimental data. Besides, differences are observed in the first second of the transient due to imperfect knowledge of initial and boundary conditions, and test execution procedure. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:856 / 860
页数:5
相关论文
共 50 条
  • [1] The LIFUS5 separate effect test facility experimental programme
    Eboli, M.
    Ciampichetti, A.
    Giannetti, F.
    Forgione, N.
    Del Nevo, A.
    NUCLEAR ENGINEERING AND DESIGN, 2023, 411
  • [2] Post-test analysis of Series D experiments in LIFUS5/Mod3 facility for SIMMER code validation of WCLL-BB In-box LOCA
    Moghanaki, Samad Khani
    Galleni, Francesco
    Eboli, Marica
    Del Nevo, Alessandro
    Paci, Sandro
    Forgione, Nicola
    FUSION ENGINEERING AND DESIGN, 2021, 165
  • [3] Post-Test Analyses of the CMMR-4 Test
    Yamashita, Takuya
    Madokoro, Hiroshi
    Sato, Ikken
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2022, 8 (02):
  • [4] The Post-Test
    Smith, Lenore Anderson
    AMERICAN JOURNAL OF NURSING, 1950, 50 (09) : 565 - 567
  • [5] Experimental Results of PbLi-Water Reaction Performed in LIFUS5/Mod3 Separate Effect Test Facility
    Badodi, Nicolo
    Cammi, Antonio
    Eboli, Marica
    Martelli, Daniele
    Del Nevo, Alessandro
    NUCLEAR TECHNOLOGY, 2023, 209 (10) : 1508 - 1522
  • [6] POST-TEST EXAMINATION RESULTS OF SLSF EXPERIMENT-P3A
    HOLLAND, JW
    KELMAN, LR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1980, 35 (NOV): : 370 - 371
  • [7] PRE-TEST AND POST-TEST ANALYSES WITH K-FIX FOR AN HDR BLOWDOWN TEST
    RIVARD, WC
    HIRT, CW
    TORREY, MD
    NUCLEAR ENGINEERING AND DESIGN, 1982, 70 (03) : 309 - 319
  • [8] CME POST-TEST
    不详
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2022, 35 (01): : 28 - 28
  • [10] CME POST-TEST
    不详
    JAAPA-JOURNAL OF THE AMERICAN ACADEMY OF PHYSICIAN ASSISTANTS, 2023, 36 (01): : 24 - 24