Heavily calcified coronary lesions preclude strut apposition despite high pressure balloon dilatation and rotational Atherectomy - In-vivo demonstration with optical coherence tomography

被引:53
|
作者
Tanigawa, Jun [1 ]
Barlis, Peter [1 ]
Di Mario, Carlo [1 ]
机构
[1] Royal Brompton Hosp, Imperial Coll, Dept Cardiol, London SW3 6LY, England
关键词
intravascular imaging; malapposition; percutaneous coronary intervention; rotablator; stents;
D O I
10.1253/circj.72.157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heavily calcified lesions (HCL) continue to present challenges that are not always solved by modern low-profile, non-compliant high-pressure balloons, or bladed balloons. Uncrossable or unexpandable lesions need lesion modification, using ablating devices such as rotational atherectomy. Three cases of HCL treated with drug-eluting stents, using a new intravascular imaging device, Optical Coherence Tomography with 10-fold superior resolution and fewer artifacts compared with conventional intravascular ultrasound, are presented. Insights from using this highly sensitive imaging technique outline the high prevalence of persistent stent strut malapposition in this group, despite the use of high-pressure dilatation or rotational atherectomy.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 24 条
  • [1] Incidence and natural course of incomplete stent apposition in heavily calcified lesions requiring rotational atherectomy prior to stenting: an optical coherence tomography study
    Kyodo, Atsushi
    Okura, Hiroyuki
    Iwai, Saki
    Okamura, Akihiko
    Kamon, Daisuke
    Hashimoto, Yukihiro
    Ueda, Tomoya
    Soeda, Tsunenari
    Watanabe, Makoto
    Saito, Yoshihiko
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B202 - B202
  • [2] Effect of cutting balloon after rotational atherectomy in severely calcified coronary artery lesions as assessed by optical coherence tomography
    Amemiya, Kisaki
    Yamamoto, Myong Hwa
    Maehara, Akiko
    Oyama, Yuji
    Igawa, Wataru
    Ono, Morio
    Kido, Takehiko
    Ebara, Seitarou
    Okabe, Toshitaka
    Yamashita, Kennosuke
    Hoshimoto, Koichi
    Saito, Shigeo
    Yakushiji, Tadayuki
    Isomura, Naoei
    Araki, Hiroshi
    Mintz, Gary S.
    Ochiai, Masahiko
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 94 (07) : 936 - 944
  • [3] THE EFFECT OF ROTATIONAL ATHERECTOMY ON COMPLEX CALCIFIED CORONARY LESIONS: SERIAL OPTICAL COHERENCE TOMOGRAPHY STUDY
    Maejima, Nobuhiko
    Hibi, Kiyoshi
    Konishi, Masaaki
    Iwahashi, Noriaki
    Tsukahara, Kengo
    Tahara, Yoshio
    Kosuge, Masami
    Ebina, Toshiaki
    Umemura, Satoshi
    Kimura, Kazuo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1779 - A1779
  • [4] White thrombi on optical coherence tomography after rotational atherectomy of severely calcified coronary lesions
    Cao, Cheng-fu
    Ma, Yu-liang
    Li, Qi
    Liu, Jian
    Zhao, Hong
    Lu, Ming-yu
    Wang, Wei-min
    HERZ, 2022, 47 (06) : 536 - 542
  • [5] OPTICAL COHERENCE TOMOGRAPHY ASSESSMENT OF CORONARY ATHERECTOMY EFFECT: COMPARISON BETWEEN ORBITAL AND ROTATIONAL ATHERECTOMY IN SEVERELY CALCIFIED LESIONS
    Yamamoto, Myong Hwa
    Maehara, Akiko
    Mintz, Gary
    Karimigalougah, Keyvan
    Kim, Sung Sik
    Amemiya, Kisaki
    Losquadro, Monica
    Haag, Elizabeth
    Moses, Jeffrey
    Sosa, Fernando
    Shlofmitz, Richard
    Ochiai, Masahiko
    Ali, Ziad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1062 - 1062
  • [6] Optical coherence tomography assessment of the mechanistic effects of rotational and orbital atherectomy in severely calcified coronary lesions
    Kini, Annapoorna S.
    Vengrenyuk, Yuliya
    Pena, Jacobo
    Motoyama, Sadako
    Feig, Jonathan E.
    Meelu, Omar A.
    Rajamanickam, Anitha
    Bhat, Arjun M.
    Panwar, Sadik
    Baber, Usman
    Sharma, Samin K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (06) : 1024 - 1032
  • [7] Automated stent strut coverage and apposition analysis of in-vivo intra coronary Optical Coherence Tomography images
    Ughi, Giovanni J.
    Adriaenssens, Tom
    Onsea, Kevin
    Kayaert, Peter
    Dubois, Christophe
    Coosemans, Mark
    Sinnaeve, Peter
    Desmet, Walter
    D'hooge, Jan
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [8] Relationship Between Thickness of Calcium on Optical Coherence Tomography and Crack Formation After Balloon Dilatation in Calcified Plaque Requiring Rotational Atherectomy
    Maejima, Nobuhiko
    Hibi, Kiyoshi
    Saka, Kenichiro
    Akiyama, Eiichi
    Konishi, Masaaki
    Endo, Mitsuaki
    Iwahashi, Noriaki
    Tsukahara, Kengo
    Kosuge, Masami
    Ebina, Toshiaki
    Umemura, Satoshi
    Kimura, Kazuo
    CIRCULATION JOURNAL, 2016, 80 (06) : 1413 - 1419
  • [9] Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage
    Ughi, G. J.
    Adriaenssens, T.
    Onsea, K.
    Kayaert, P.
    Dubois, C.
    Sinnaeve, P.
    Coosemans, M.
    Desmet, W.
    D'hooge, J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (02): : 229 - 241
  • [10] Comparison of optical coherence tomography-guided and intravascular ultrasound-guided rotational atherectomy for calcified coronary lesions
    Teng, Weili
    Li, Qi
    Ma, Yuliang
    Cao, Chengfu
    Liu, Jian
    Zhao, Hong
    Lu, Mingyu
    Hou, Chang
    Wang, Weimin
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)