Distribution of innervation zone and muscle fiber conduction velocity in the biceps brachii muscle

被引:1
|
作者
Li, Xiaoyan [1 ,2 ]
Huang, Chengjun [3 ]
Lu, Zhiyuan [4 ]
Wang, Inga [5 ]
Klein, Cliff S. [6 ]
Zhang, Liqun [1 ,7 ]
Zhou, Ping [4 ]
机构
[1] Univ Maryland College Pk, Fischell Dept Bioengn, College Pk, MD USA
[2] Med Coll Wisconsin, Dept Neurol, Milwaukee, WI 53226 USA
[3] Baylor Coll Med, Dept Neurosci, Houston, TX 77030 USA
[4] Univ Hlth & Rehabil Sci, Fac Biomed & Rehabil Engn, Qingdao, Shandong, Peoples R China
[5] Univ Wisconsin Milwaukee, Dept Rehabil Sci & Technol, Milwaukee, WI USA
[6] Guangdong Work Injury Rehabil Ctr, Guangzhou, Guangdong, Peoples R China
[7] Univ Maryland Baltimore, Dept Phys Therapy & Rehabil Sci, Baltimore, MD USA
关键词
Innervation zone; Radon transform; Muscle conduction velocity; Surface electromyography (EMG); Muscle; MOTOR UNITS; LOCALIZATION; LOCATIONS; SHIFT; SIZE; EMG;
D O I
10.1016/j.jelekin.2022.102637
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The spatial distributions of muscle innervation zone (IZ) and muscle fiber conduction velocity (CV) were examined in nine healthy young male participants. High-density surface electromyography (EMG) was collected from the biceps brachii muscle when subjects performed isometric elbow flexions at 20% to 80% of the maximal voluntary contraction (MVC). A total of 9498 samples of IZs were identified and CVs were calculated using the Radon transform. The center and width of IZ sample distribution were compared within four different force levels and six medial to lateral electrode column positions using repeated measures ANOVA and multiple comparison tests. Significant shifts of IZ center were observed in the medial columns (Columns 5, 6, and 7) compared with the lateral columns (Columns 3 and 4) (p < 0.05). Similarly, significant differences in the IZ width were found in Column 7 and 8 compared to Column 3 (p < 0.05). In contrast, muscle CV was unaffected by column position. Instead, muscle CV was faster at 40% and 80% MVC compared to 20% MVC (p < 0.05). The findings of this study add further insights into the physiological properties of the biceps brachii muscle.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Effect of innervation-zone distribution on estimates of average muscle-fiber conduction velocity
    Nielsen, Mogens
    Graven-Nielsen, Thomas
    Farina, Dario
    MUSCLE & NERVE, 2008, 37 (01) : 68 - 78
  • [2] Innervation zone shift at different levels of isometric contraction in the biceps brachii muscle
    Piitulainen, Harri
    Rantalainen, Timo
    Linnamo, Vesa
    Komi, Paavo
    Avela, Janne
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (04) : 667 - 675
  • [3] Measurements of muscle fiber conduction velocity at the M. biceps and M. Triceps brachii under isometric load
    Hering, G.O.
    Hennig, E.M.
    Riehle, H.J.
    Journal of Biomechanics, 1989, 22 (10)
  • [4] Muscle fiber number in the biceps brachii muscle of young and old men
    Klein, CS
    Marsh, GD
    Petrella, RJ
    Rice, CL
    MUSCLE & NERVE, 2003, 28 (01) : 62 - 68
  • [5] THE RAT BICEPS BRACHII MUSCLE, ITS INNERVATION AND MOTOR UNIT SIZE
    CURTIN, WA
    FRAHER, JP
    IRISH JOURNAL OF MEDICAL SCIENCE, 1981, 150 (03) : 99 - 99
  • [6] MUSCLE ACTIVIATION VARIABILITY IN THE BICEPS BRACHII MUSCLE
    Kurrant, A. B.
    Kerner, M. S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S88 - S88
  • [7] ANOMALIES OF THE BICEPS BRACHII MUSCLE
    KHALEDPOUR, C
    ANATOMISCHER ANZEIGER, 1985, 158 (01): : 79 - 85
  • [8] Higher torque and muscle fibre conduction velocity of the Biceps Brachii in karate practitioners during isokinetic contractions
    Quinzi, Federico
    Bianchetti, Andrea
    Felici, Francesco
    Sbriccoli, Paola
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 40 : 81 - 87
  • [9] Effects of passive stretching on post-activation potentiation and fibre conduction velocity of biceps brachii muscle
    Cè E.
    Rampichini S.
    Maggioni M.A.
    Veicsteinas A.
    Merati G.
    Sport Sciences for Health, 2008, 4 (3) : 43 - 50
  • [10] Innervation zone distribution of the biceps brachii muscle examined using voluntary and electrically-evoked high-density surface EMG
    Chengjun Huang
    Cliff S. Klein
    Zhaojian Meng
    Yingchun Zhang
    Sheng Li
    Ping Zhou
    Journal of NeuroEngineering and Rehabilitation, 16