Robust Adaptive Extended Kalman Filtering for Real Time MR-Thermometry Guided HIFU Interventions

被引:36
|
作者
Roujol, Sebastien [1 ,2 ]
de Senneville, Baudouin Denis [1 ]
Hey, Silke [1 ]
Moonen, Chrit [1 ]
Ries, Mario [1 ]
机构
[1] Univ Victor Segalen Bordeaux, FRE CNRS 3313, Lab Mol & Funct Imaging Physiol Therapy, F-33076 Bordeaux, France
[2] Univ Bordeaux, UMR CNRS 5800, Lab Bordelais Rech Informat, F-33405 Talence, France
关键词
Biomedical signal processing; Kalman filters; magnetic resonance imaging (MRI); real time systems;
D O I
10.1109/TMI.2011.2171772
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Real time magnetic resonance (MR) thermometry is gaining clinical importance formonitoring and guiding high intensity focused ultrasound (HIFU) ablations of tumorous tissue. The temperature information can be employed to adjust the position and the power of the HIFU system in real time and to determine the therapy endpoint. The requirement to resolve both physiological motion of mobile organs and the rapid temperature variations induced by state-of-the-art high-power HIFU systems require fast MRI-acquisition schemes, which are generally hampered by low signal-to-noise ratios (SNRs). This directly limits the precision of real time MR-thermometry and thus in many cases the feasibility of sophisticated control algorithms. To overcome these limitations, temporal filtering of the temperature has been suggested in the past, which has generally an adverse impact on the accuracy and latency of the filtered data. Here, we propose a novel filter that aims to improve the precision of MR-thermometry while monitoring and adapting its impact on the accuracy. For this, an adaptive extended Kalman filter using a model describing the heat transfer for acoustic heating in biological tissues was employed together with an additional outlier rejection to address the problem of sparse artifacted temperature points. The filter was compared to an efficient matched FIR filter and outperformed the latter in all tested cases. The filter was first evaluated on simulated data and provided in the worst case (with an approximate configuration of the model) a substantial improvement of the accuracy by a factor 3 and 15 during heat up and cool down periods, respectively. The robustness of the filter was then evaluated during HIFU experiments on a phantom and in vivo in porcine kidney. The presence of strong temperature artifacts did not affect the thermal dose measurement using our filter whereas a high measurement variation of 70% was observed with the FIR filter.
引用
收藏
页码:533 / 542
页数:10
相关论文
共 50 条
  • [1] ROBUST REAL TIME MOTION ESTIMATION FOR MR-THERMOMETRY
    Roujol, S.
    Ries, M.
    Moonen, C.
    de Senneville, B. Denis
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 508 - 511
  • [2] EXTENDED KALMAN FILTERING FOR MR-THERMOMETRY GUIDED HIGH INTENSITY FOCUSED ULTRASOUND USING THE BIO HEAT TRANSFER EQUATION
    Roujol, S.
    de Senneville, B. Denis
    Hey, S.
    Moonen, C.
    Ries, M.
    2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011,
  • [3] An Adaptive Non-Local-Means Filter for Real-Time MR-Thermometry
    Zachiu, Cornel
    Ries, Mario
    Moonen, Chrit
    de Senneville, Baudouin Denis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (04) : 904 - 916
  • [4] ADAPTIVE REJECTION OF OUTLIERS FOR ROBUST MOTION COMPENSATION IN CARDIAC MR-THERMOMETRY
    Emilien, Aurelie
    Benois-Pineau, Jenny
    Elbes, Delphine
    Quesson, Bruno
    2013 20TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2013), 2013, : 2514 - 2518
  • [5] Inter-costal Liver Ablation Under Real Time MR-Thermometry With Partial Activation Of A HIFU Phased Array Transducer
    Quesson, Bruno
    Merle, Mathilde
    Koehler, Max
    Mougenot, Charles
    Roujol, Sebastien
    de Senneville, Baudouin Denis
    Moonen, Chrit
    9TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2010, 1215 : 243 - +
  • [6] Real-Time MR-Thermometry and Dosimetry for Interventional Guidance on Abdominal Organs
    Roujol, Sebastien
    Ries, Mario
    Quesson, Bruno
    Moonen, Chrit
    de Senneville, Baudouin Denis
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1080 - 1087
  • [7] Real-Time MR Thermometry for Monitoring HIFU Ablations of the Liver
    Holbrook, Andrew B.
    Santos, Juan M.
    Kaye, Elena
    Rieke, Viola
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 365 - 373
  • [8] Deep correction of breathing-related artifacts in real-time MR-thermometry
    de Senneville, B. Denis
    Coupe, P.
    Ries, M.
    Facq, L.
    Moonen, C. T. W.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2021, 87
  • [9] Practical implementation of robust MR-thermometry during clinical MR-guided microwave ablations in the liver at 1.5 T
    Gorny, K. R.
    Favazza, C. P.
    Lu, A.
    Felmlee, J. P.
    Hangiandreou, N. J.
    Browne, J. E.
    Stenzel, W. S.
    Muggli, J. L.
    Anderson, A. G.
    Thompson, S. M.
    Woodrum, D. A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 67 : 91 - 99
  • [10] Real-Time Cooperative Adaptive Robust Relay Beamforming Based on Kalman Filtering Channel Estimation
    Sadr, Mohammad Amin Maleki
    Ahmadian-Attari, Mahmoud
    Amiri, Rouhollah
    IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2019, 18 (12) : 5600 - 5612