Dose response and Bragg curve reconstruction by radiophotoluminescence of color centers in lithium fluoride crystals irradiated with 35 MeV proton beams from 0.5 to 50 Gy

被引:26
|
作者
Piccinini, M. [1 ]
Nichelatti, E. [2 ]
Ampollini, A. [1 ]
Bazzano, G. [1 ]
De Angelis, C. [3 ]
Della Monaca, S. [3 ]
Nenzi, P. [1 ]
Picardi, L. [1 ]
Ronsivalle, C. [1 ]
Surrenti, V [1 ]
Trinca, E. [1 ]
Vadrucci, M. [1 ]
Vincenti, M. A. [1 ]
Montereali, R. M. [1 ]
机构
[1] Fus & Technol Nucl Safety & Secur Dept, ENEA CR Frascati, Via E Fermi 45, I-00044 Rome, Italy
[2] ENEA CR Casaccia, Fus & Technol Nucl Safety & Secur Dept, Via Anguillarese 301, I-00123 Rome, Italy
[3] Ist Super Sanita, Viale Regina Elena 299, I-00161 Rome, Italy
关键词
LiF; Color centers; Proton beams; Radiophotoluminescence; Bragg curve; F-AGGREGATE CENTERS; ANALYTICAL APPROXIMATION; PHOTOLUMINESCENCE; F-2;
D O I
10.1016/j.radmeas.2020.106275
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Passive solid-state radiation detectors, based on the radiophotoluminescence of stable color centers in nominally pure lithium fluoride (LiF) crystals, have been used for advanced diagnostics of the segment up to 35 MeV of the TOP-IMPLART proton linear accelerator for protontherapy applications, under development at ENEA Frascati. In LiF, proton beams generate a spatial distribution of F-2 and F-3(+) aggregate color centers, which efficiently emit radiophotoluminescence in the red-green spectral range under optical pumping around 450 nm. LiF crystals were irradiated with 35 MeV nominal energy protons at several doses of interest for protontherapy (from 0.5 to 50 Gy). For the first time is shown here the possibility of measuring the radiophotoluminescence spectra of proton irradiated LiF even at such low doses and how the signal showed a linear behavior with dose with a good signal-to-noise ratio. A Bragg-curve image, stored as color-center distribution in a LiF crystal after a 50 Gy-dose irradiation in a particular geometry, was acquired in a conventional fluorescence microscope. After appropriate image processing, the signal intensity resulted to be proportional to the linear energy transfer along the whole Bragg curve. By best-fitting it with an ad-hoc analytical formula, the depth-dose distribution was reconstructed and the proton beam energy and energy spread were estimated.
引用
收藏
页数:4
相关论文
共 4 条
  • [1] Dose response of visible color center radiophotoluminescence in lithium fluoride crystals irradiated with a reference 60Co gamma beam in the 1-20 Gy dose range
    Piccinini, M.
    Nichelatti, E.
    Pimpinella, M.
    De Coste, V
    Montereali, R. M.
    RADIATION MEASUREMENTS, 2022, 151
  • [2] Evaluation of saturation dose in spatial distributions of color centers generated by 18 MeV proton beams in lithium fluoride
    Nichelatti, E.
    Piccinini, M.
    Ronsivalle, C.
    Picardi, L.
    Vincenti, M. A.
    Montereali, R. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 464 : 100 - 105
  • [3] Visible photoluminescence of color centers in lithium fluoride detectors for low-energy proton beam Bragg curve imaging and dose mapping
    Montereali, Rosa Maria
    Piccinini, Massimo
    Ampollini, Alessandro
    Picardi, Luigi
    Ronsivalle, Concetta
    Bonfigli, Francesca
    Nichelatti, Enrico
    Vincenti, Maria Aurora
    OPTICAL MATERIALS, 2019, 95
  • [4] Spectral analysis of visible photoluminescence from F2 and F3+ color centers in low-dose gamma-irradiated lithium fluoride crystals at increasing excitation power
    Nichelatti, E.
    Piccinini, M.
    Pimpinella, M.
    De Coste, V
    Montereali, R. M.
    JOURNAL OF LUMINESCENCE, 2022, 241