Evaluation of in vivo wear of vitamin E-diffused highly crosslinked polyethylene at five years A MULTICENTRE RADIOSTEREOMETRIC ANALYSIS STUDY

被引:39
|
作者
Galea, V. P. [2 ]
Connelly, J. W. [2 ]
Shareghi, B. [1 ,3 ]
Karrholm, J. [1 ,3 ]
Skoldenberg, O. [1 ,4 ]
Salemyr, M. [1 ,4 ]
Laursen, M. B. [1 ,5 ]
Muratoglu, O. [2 ,6 ]
Bragdon, C. [2 ,6 ]
Malchau, H. [2 ,6 ]
机构
[1] Massachusetts Gen Hosp, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Harris Orthopaed Lab, Boston, MA 02114 USA
[3] Univ Gothenburg, Sahlgrenska Acad, Dept Orthopaed, Inst Clin Sci, Gothenburg, Sweden
[4] Karolinska Inst, Div Orthopaed, Danderyd Hosp, Dept Clin Sci, Stockholm, Sweden
[5] Aalborg Univ Hosp, Dept Orthopaed, Aalborg, Denmark
[6] Harvard Med Sch, Dept Orthopaed Surg, Boston, MA USA
来源
BONE & JOINT JOURNAL | 2018年 / 100B卷 / 12期
关键词
MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; OXIDATION; RSA; OSTEOLYSIS; RESISTANCE;
D O I
10.1302/0301-620X.100B12.BJJ-2018-0371.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure. Patients and Methods A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery. Results We observed similar bedding in one year postoperatively and wear two years postoperatively between the two types of liner. However, there was significantly more penetration of the femoral head in the ModXLPE cohort compared with the VEPE cohort five years postoperatively (p < 0.001). The only variables independently predictive of increased wear were ModXLPE (vs VEPE) liner type (beta = 0.22, p = 0.010) and metal (vs ceramic) femoral head (beta = 0.21, p = 0.013). There was no association between increased wear and the development of radiolucency (p = 0.866) or PROMs. No patient had evidence of osteolysis. Conclusion Five years postoperatively, patients with VEPE (vs ModXLPE) and ceramic (vs metal) femoral heads had decreased wear. The rates of wear for both liners were very low and have not led to any osteolysis or implant failure due to aseptic loosening.
引用
收藏
页码:1592 / 1599
页数:8
相关论文
共 40 条
  • [1] Five-Year Experience of Vitamin E-Diffused Highly Cross-Linked Polyethylene Wear in Total Hip Arthroplasty Assessed by Radiostereometric Analysis
    Nebergall, Audrey K.
    Troelsen, Anders
    Rubash, Harry E.
    Malchau, Henrik
    Rolfson, Ola
    Greene, Meridith E.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06): : 1251 - 1255
  • [2] Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis
    Galea, V. P.
    Rejanasopondist, P.
    Laursen, M.
    Muratoglu, O. K.
    Malchau, H.
    Bragdon, C.
    BONE & JOINT JOURNAL, 2019, 101B (07): : 760 - 767
  • [3] Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study
    Campbell, David G.
    Callary, Stuart A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2022, 480 (03) : 485 - 491
  • [4] In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty
    Tsunehiro Matsuoka
    Yasuhito Takahashi
    Tsunehito Ishida
    Toshiyuki Tateiwa
    Takaaki Shishido
    Kengo Yamamoto
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7195 - 7203
  • [5] In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty
    Matsuoka, Tsunehiro
    Takahashi, Yasuhito
    Ishida, Tsunehito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Yamamoto, Kengo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7195 - 7203
  • [6] Size and thickness effect on creep behavior in conventional and vitamin E-diffused highly crosslinked polyethylene for total hip arthroplasty
    Takahashi, Yasuhito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Masaoka, Toshinori
    Kubo, Kosuke
    Yamamoto, Kengo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 62 : 399 - 406
  • [7] CORR Insights®: Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study
    Goodman, Stuart B.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2022, 480 (03) : 492 - 494
  • [8] Vitamin E diffused highly cross-linked polyethylene in total hip arthroplasty at five years
    Nebergall, A. K.
    Greene, M. E.
    Laursen, M. B.
    Nielsen, P. T.
    Malchau, H.
    Troelsen, A.
    BONE & JOINT JOURNAL, 2017, 99-B (05): : 577 - 584
  • [9] Post-deformation shape-recovery behavior of vitamin E-diffused, radiation crosslinked polyethylene acetabular components
    Takahashi, Yasuhito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Masaoka, Toshinori
    Kubo, Kosuke
    Yamamoto, Kengo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 63 : 399 - 406
  • [10] Wear of Vitamin E-Infused Highly Cross-Linked Polyethylene at Five Years