Stress echocardiography with smartphone: real-time remote reading for regional wall motion

被引:8
|
作者
Scali, Maria Chiara [1 ,15 ]
de Azevedo Bellagamba, Clarissa Carmona [2 ]
Ciampi, Quirino [3 ]
Simova, Iana [4 ]
de Castro e Silva Pretto, Jose Luis [5 ,6 ]
Djordjevic-Dikic, Ana [7 ]
Dodi, Claudio [8 ]
Cortigiani, Lauro [9 ]
Zagatina, Angela [10 ]
Trambaiolo, Paolo [11 ]
Torres, Marco R. [2 ]
Citro, Rodolfo [12 ]
Colonna, Paolo [13 ]
Paterni, Marco [14 ]
Picano, Eugenio [14 ]
机构
[1] Nottola Hosp, Div Cardiol, Siena, Italy
[2] Univ Fed Rio Grande do Sul, Hosp Clin Porto Alegre, Porto Alegre, RS, Brazil
[3] Fatebenefratelli Hosp, Div Cardiol, Benevento, Italy
[4] Univ Hosp, Acibadem City Clin Cardiovasc Ctr, Sofia, Bulgaria
[5] Hosp Sao Vicente Paulo, Passo Fundo, Brazil
[6] Hosp Cidade, Passo Fundo, Brazil
[7] Univ Belgrade, Sch Med, Cardiol Clin, Clin Ctr Serbia, Belgrade, Serbia
[8] Casa Cura Figlie San Camillo, Cremona, Italy
[9] San Luca Hosp, Dept Cardiol, Lucca, Italy
[10] Medika Cardioctr, Dept Cardiol, St Petersburg, Russia
[11] Sandro Pertini Hosp, Dept Cardiol, Rome, Italy
[12] Univ Hosp San Giovanni di Dio & Ruggi dAragona, Heart Dept, Salerno, Italy
[13] Policlin Bari, Heart Cardiol Hosp, Bari, Italy
[14] CNR, Inst Clin Physiol, Biomed Dept, CNR, Via Moruzzi 1, I-56124 Pisa, Italy
[15] Cisanello, Cardiothorac Dept, Pisa, Italy
来源
关键词
Echocardiography; Stress echocardiography; Wall motion; AMERICAN SOCIETY; EUROPEAN ASSOCIATION; RECOMMENDATIONS; WHATSAPP;
D O I
10.1007/s10554-017-1167-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The diffusion of smart-phones offers access to the best remote expertise in stress echo (SE). To evaluate the reliability of SE based on smart-phone filming and reading. A set of 20 SE video-clips were read in random sequence with a multiple choice six-answer test by ten readers from five different countries (Italy, Brazil, Serbia, Bulgaria, Russia) of the "SE2020" study network. The gold standard to assess accuracy was a core-lab expert reader in agreement with angiographic verification (0 = wrong, 1 = right). The same set of 20 SE studies were read, in random order and > 2 months apart, on desktop Workstation and via smartphones by ten remote readers. Image quality was graded from 1 = poor but readable, to 3 = excellent. Kappa (k) statistics was used to assess intra- and inter-observer agreement. The image quality was comparable in desktop workstation vs. smartphone (2.0 +/- 0.5 vs. 2.4 +/- 0.7, p = NS). The average reading time per case was similar for desktop versus smartphone (90 +/- 39 vs. 82 +/- 54 s, p = NS). The overall diagnostic accuracy of the ten readers was similar for desktop workstation vs. smartphone (84 vs. 91%, p = NS). Intra-observer agreement (desktop vs. smartphone) was good (k = 0.81 +/- 0.14). Inter-observer agreement was good and similar via desktop or smartphone (k = 0.69 vs. k = 0.72, p = NS). The diagnostic accuracy and consistency of SE reading among certified readers was high and similar via desktop workstation or via smartphone.
引用
收藏
页码:1731 / 1736
页数:6
相关论文
共 50 条
  • [1] Stress echocardiography with smartphone: real-time remote reading for regional wall motion
    Maria Chiara Scali
    Clarissa Carmona de Azevedo Bellagamba
    Quirino Ciampi
    Iana Simova
    José Luis de Castro e Silva Pretto
    Ana Djordjevic-Dikic
    Claudio Dodi
    Lauro Cortigiani
    Angela Zagatina
    Paolo Trambaiolo
    Marco R. Torres
    Rodolfo Citro
    Paolo Colonna
    Marco Paterni
    Eugenio Picano
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1731 - 1736
  • [2] Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography
    Collins, M
    Hsieh, A
    Ohazama, CJ
    Ota, T
    Stetten, G
    Donovan, CL
    Kisslo, J
    Ryan, T
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (01) : 7 - 14
  • [3] Assessment of regional wall motion abnormalities using real-time 3D echocardiography
    Collins, M
    Hsieh, A
    Ohazama, CJ
    Ota, T
    Stetten, G
    Strub, M
    Donovan, CL
    vonRamm, OT
    Kisslo, J
    Ryan, T
    CIRCULATION, 1996, 94 (08) : 4018 - 4018
  • [4] Real-time myocardial perfusion contrast echocardiography and regional wall motion abnormalities after aneurysmal subarachnoid hemorrhage
    Abdelmoneim, Sahar S.
    Wijdicks, Eelco F. M.
    Lee, Viven H.
    Daugherty, Wilson P.
    Bernier, Mathieu
    Oh, Jae K.
    Pellikka, Patricia A.
    Mulvagh, Sharon L.
    JOURNAL OF NEUROSURGERY, 2009, 111 (05) : 1023 - 1028
  • [5] Real-time quantitative wall motion coding in two-dimensional echocardiography
    Berg, S
    Torp, AH
    Schipper, KP
    Olstad, B
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 413 - 423
  • [6] Quantitative evaluation of left ventricular regional wall motion using a real-time wall thickness curve system with two-dimensional echocardiography
    Mizushige, K
    Furumoto, W
    Hirao, K
    Iwado, Y
    Ohmori, K
    Matsuo, H
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (10): : 1204 - 1208
  • [7] REAL-TIME ASSESSMENT OF REGIONAL MID-WALL MYOCARDIAL MOTION IN MAN
    HILL, RC
    KLEINMAN, LH
    CHITWOOD, WR
    WECHSLER, AS
    SURGICAL FORUM, 1978, 29 : 256 - 258
  • [8] Contrast enhanced real-time 3D stress echocardiography: qualitative and quantitative analysis of abnormal wall motion
    Kapetanakis, S
    Monaghan, MJ
    EUROPEAN HEART JOURNAL, 2004, 25 : 262 - 262
  • [9] Real-time vs off-line evaluation of intraoperative regional wall motion abnormalities (RWMA) with transesophageal echocardiography (TEE) during dobutamine stress test
    Bolduc, L
    Couture, P
    Tardif, JC
    Denault, A
    Pellerin, M
    Hardy, JF
    ANESTHESIA AND ANALGESIA, 2000, 90 (02): : U123 - U123
  • [10] Real-time dobutamine stress myocardial contrast echocardiography for detecting coronary artery disease: Correlating abnormal wall motion and disturbed perfusion
    Chiou, KR
    Huang, WC
    Lin, SL
    Hsieh, PL
    Liu, CP
    Tsay, DG
    Chiang, HT
    CANADIAN JOURNAL OF CARDIOLOGY, 2004, 20 (12) : 1237 - 1243