Dynamic K-edge Subtraction Fluoroscopy at a Compact Inverse-Compton Synchrotron X-ray Source

被引:8
|
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Brantl, Johannes [1 ,2 ]
Busse, Madleen [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
关键词
DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; RADIATION; GADOLINIUM; FEASIBILITY; PERFORMANCE;
D O I
10.1038/s41598-020-66414-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray fluoroscopy is a commonly applied diagnostic tool for morphological and functional evaluation of the intestine in clinical routine. Acquisition of repetitive X-ray images following oral or rectal application of iodine contrast agent visualizes the time dependent distribution of the contrast medium, and helps to detect for example leakages, tumors or functional disorders. However, movements of the intestine and air trapped inside usually prevent temporal subtraction imaging to be applied to fluoroscopy of the gastrointestinal tract. K-edge subtraction (KES) imaging would enable subtraction fluoroscopy because it allows for imaging of moving organs with little artefacts. Although KES imaging is a well established technique at synchrotron sources, this imaging method is not applied in clinical routine as it relies on brilliant synchrotron radiation. Recently emerging compact synchrotron X-ray sources could provide a quasi-monochromatic, high-flux X-ray beam and allow for the application of KES in a laboratory environment. Here, we present a filter-based dynamic KES approach at the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. Compared to conventional temporal subtraction X-ray radiography, our approach increases the contrast while reducing the generated image artefacts.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Dynamic K-edge Subtraction Fluoroscopy at a Compact Inverse-Compton Synchrotron X-ray Source
    Stephanie Kulpe
    Martin Dierolf
    Benedikt Günther
    Johannes Brantl
    Madleen Busse
    Klaus Achterhold
    Bernhard Gleich
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 10
  • [2] K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Busse, Madleen
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source
    Stephanie Kulpe
    Martin Dierolf
    Benedikt Günther
    Madleen Busse
    Klaus Achterhold
    Bernhard Gleich
    Julia Herzen
    Ernst Rummeny
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 9
  • [4] Inverse Compton radiation: a novel x-ray source for K-edge subtraction angiography?
    Paterno, G.
    Cardarelli, P.
    Gambaccini, M.
    Serafini, L.
    Petrillo, V
    Drebot, I
    Taibi, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [5] K-edge subtraction imaging for coronary angiography with a compact synchrotron X-ray source
    Kulpe, Stephanie
    Dierolf, Martin
    Braig, Eva
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    PLOS ONE, 2018, 13 (12):
  • [6] K-edge subtraction imaging for iodine and calcium separation at a compact synchrotron x-ray source
    Kulpe, Stephanie
    Dierolf, Martin
    Braig, Eva-Maria
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (02)
  • [7] Author Correction: K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source
    Stephanie Kulpe
    Martin Dierolf
    Benedikt Günther
    Madleen Busse
    Klaus Achterhold
    Bernhard Gleich
    Julia Herzen
    Ernst Rummeny
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 10
  • [8] K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source (vol 9, 1332, 2019)
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Busse, Madleen
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] K-edge digital subtraction imaging based on a dichromatic and compact x-ray source
    Sarnelli, A
    Taibi, A
    Tuffanelli, A
    Baldazzi, G
    Bollini, D
    Rodriguez, AEC
    Gombia, M
    Prino, F
    Ramello, L
    Tomassi, E
    Gambaccini, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3291 - 3305
  • [10] K-edge subtraction imaging for angiography at a compact synchrotron source
    Kulpe, Stephanie
    Dierolf, Martin
    Braig, Eva-Maria
    Guenther, Benedikt
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII, 2019, 11110