Single-centre experience with coronary sinus lead stability and tong-term pacing parameters

被引:28
作者
Bulava, Alan [1 ]
Luki, Jan [1 ]
机构
[1] Univ Hosp, Dept Internal Med, Olomouc, Czech Republic
来源
EUROPACE | 2007年 / 9卷 / 07期
关键词
CS lead stability; long-term performance; biventricutar pacing;
D O I
10.1093/europace/eum082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare both short- and long-term stability and pacing parameters of CS leads. Long-term maintenance of coronary sinus (CS) pacing lead position has not yet been assessed by serial X-ray digital imaging. Methods and results Using X-ray digital imaging in anteroposterior and left lateral views, we performed analysis of the CS lead position at the end of the implantation procedure, 48 h following implantation and after 12 months in 93 consecutive patients. Attain OTW leads, QuickSite leads and EasyTrak leads were implanted in 44, 12 and 37 cases, respectively. X-ray detectable late CS lead dislodgement was observed in 8 cases (8.6%) during 12-months follow-up. Dislodgment was once accompanied by toss of capture and need for repositioning. Another two major dislodgements occurred without any threshold change. Five (5.4%) minor dislocations occurred with either a decrease or an increase in pacing threshold. Left ventricular (LV) pacing threshold was changed by >= 1 V after 12 months in 14 patients (15%) when compared to values 48 h after implantation. All but one case of >= 1 V threshold change (either positive or negative) occurred without any radiological evidence of lead displacement. IV pacing threshold was significantly higher than RV pacing threshold at both baseline and during follow-up. Leads from all three manufacturers had comparable pacing thresholds 12 months following implantation. Conclusion The position of CS leads may change during 1-year follow-up. However, it rarely required reoperation in the selected group of patients. Long-term pacing parameters between different manufacturers are comparable. Increase in pacing threshold is not a reliable marker of CS lead dislodgement.
引用
收藏
页码:523 / 527
页数:5
相关论文
共 8 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects [J].
Alonso, C ;
Leclercq, C ;
d'Allonnes, FR ;
Pavin, D ;
Victor, F ;
Mabo, P ;
Daubert, JC .
HEART, 2001, 86 (04) :405-410
[3]   Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients [J].
Butter, C ;
Auricchio, A ;
Stellbrink, C ;
Fleck, E ;
Ding, J ;
Yu, YH ;
Huvelle, E ;
Spinelli, J .
CIRCULATION, 2001, 104 (25) :3026-3029
[4]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[5]   Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure -: Combined results of over 2,000 patients from a multicenter study program [J].
León, AR ;
Abraham, WT ;
Curtis, AB ;
Daubert, JP ;
Fisher, WG ;
Gurley, J ;
Hayes, DL ;
Lieberman, R ;
Petersen-Stejskal, S ;
Wheelan, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) :2348-2356
[6]  
Ricci R, 2000, EUR HEART J SUPPL, V2, pJ6
[7]   Comparison of medical therapy, pacing and defibrillation in heart failure (COMPANION) trial terminated early; combined biventricular pacemaker-defibrillators reduce all-cause mortality and hospitalization [J].
Salukhe, TV ;
Francis, DP ;
Sutton, R .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 87 (2-3) :119-120
[8]   Adverse events with transvenous left ventricular pacing in patients with severe heart failure: early experience from a single centre [J].
Valls-Bertault, V ;
Mansourati, J ;
Gilard, M ;
Etienne, Y ;
Munier, S ;
Blanc, JJ .
EUROPACE, 2001, 3 (01) :60-63