Translational research on clinically failed zirconia implants

被引:23
|
作者
Scherrer, Susanne S. [1 ]
Mekki, Mustapha [1 ]
Crottaz, Claude [2 ]
Gahlert, Michael [3 ,4 ]
Romelli, Eric [5 ]
Marger, Laurine [1 ]
Durual, Stephane [1 ]
Vittecoq, Eric [6 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, 1 Rue Michel Servet, CH-1204 Geneva, Switzerland
[2] Univ Hosp Geneva, Dept Surg, Unit Oral Surg & Implantol, Geneva, Switzerland
[3] Hightech Res Ctr, Clin Oral & Craniomaxillofacial Surg, Basel, Switzerland
[4] Private Dent Clin, Munich, Germany
[5] Univ Geneva, Univ Clin Dent Med, Div Cariol & Endodontol, Geneva, Switzerland
[6] Univ Appl Sci Western Switzerland HES SO, HEPIA, Geneva, Switzerland
关键词
Fracture; Zirconia; Implants; Fractography; Bending moment; Clinical failure; FAILURE ANALYSIS; DENTAL IMPLANTS; Y-TZP; TITANIUM; TRANSFORMATION; DEGRADATION; RELIABILITY; PERFORMANCE; MICROSCOPY; STRENGTH;
D O I
10.1016/j.dental.2018.11.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. To provide fractographic analysis of clinically fractured zirconia implants recovered with their cemented crown. To calculate bending moments, corresponding stress and crack onset location on the implant's fracture surface using a mathematical model integrating spatial coordinates of the crown-implant part and occlusal loading obtained from 2D and 3D images. Methods. 15 fractured zirconia implants parts (11 posterior and 4 anterior) with their all-ceramic crowns still cemented on it were recovered. The implants were first generations from four manufacturers (AXIS Biodental, Z-Systems, Straumann, Swiss Dental Solutions). The time-to-failure varied between 2 weeks and 9 years. Fractography was performed identifying the failure origin and characteristic surface crack features. From 2D and 3D digital images of the crown-implant part, spatial coordinates anchoring the crown's occlusal contacts with the implant's central axis and reference plane were integrated in a mathematical model spreadsheet. Loads of 500 N in total were selectively distributed over identified occlusal contacts from wear patterns. The resultant bending and torsion moments, corresponding shear, tensile, maximum principal stress and von Mises stress were calculated. The fracture crack onset location on the implant's fracture surface was given by an angular position with respect to an occlusal reference and compared with the location of the fracture origin identified from fractographic analysis. Results. Implants fractured from the periphery of the smaller inner diameter between two threads at the bone-entrance level except for one implant which failed half-way within the bone. The porous coating (AXIS Biodental) and the large grit alumina sandblasting (Z-System) created surface defects directly related to the fracture origin. The model spreadsheet showed how occlusal loading with respect to the implant's central axis affects bending moments and crack onset. Dominant loads distributed on contacts with important wear pattern provided a calculated crack onset location in good agreement with the fractographic findings of the fracture origin. Significance. Recovered broken zirconia implant parts with their restorative crowns can provide not only information regarding the failure origin using fractography but also knowledge regarding occlusal crown loading with respect to the implant's axis. The mathematical model was helpful in showing how occlusal loading affects the location of the fracture initiation site on clinical zirconia implant fracture cases. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:368 / 388
页数:21
相关论文
共 50 条
  • [1] Fractal analysis at varying locations of clinically failed zirconia dental implants
    Jodha K.S.
    Salazar Marocho S.M.
    Scherrer S.S.
    Griggs J.A.
    Dental Materials, 2020, 36 (08): : 1052 - 1058
  • [2] Fractal analysis at varying locations of clinically failed zirconia dental implants
    Jodha, Kartikeya S.
    Marocho, Susana M. Salazar
    Scherrer, Susanne S.
    Griggs, Jason A.
    DENTAL MATERIALS, 2020, 36 (08) : 1052 - 1058
  • [3] Fracture analysis of one/two-piece clinically failed zirconia dental implants
    Zhang, Fei
    Monzavi, Mona
    Li, Maoyin
    Oki, Stevan C.
    Manesh, Al
    Nowzari, Hessam
    Vleugels, Jef
    Van Meerbeek, Bart
    DENTAL MATERIALS, 2022, 38 (10) : 1633 - 1647
  • [4] Thirty Years of Translational Research in Zirconia Dental Implants: A Systematic Review of the Literature
    Siddiqi, Allauddin
    Khan, Abdul Samad
    Zafar, Sobia
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (04) : 314 - 326
  • [5] Histopathologic retrieval analysis of clinically failed porous tantalum osteonecrosis implants
    Tanzer, M.
    Bobyn, J. D.
    Krygier, J. J.
    Karabasz, D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06): : 1282 - 1289
  • [6] Will Zirconia Implants Replace Titanium Implants?
    Webber, Liana Preto
    Chan, Hsun-Liang
    Wang, Hom-Lay
    APPLIED SCIENCES-BASEL, 2021, 11 (15):
  • [7] Zirconia Implants: Is There a Future?
    Piconi C.
    Sprio S.
    Current Oral Health Reports, 2018, 5 (3) : 186 - 193
  • [8] Performance of zirconia implants
    Wilson N.H.F.
    Blum I.R.
    Evidence-Based Dentistry, 2019, 20 (3) : 92 - 93
  • [9] Scientific Trends in Clinical Research on Zirconia Dental Implants: A Bibliometric Review
    Lorusso, Felice
    Noumbissi, Sammy
    Francesco, Inchingolo
    Rapone, Biagio
    Khater, Ahmad G. A.
    Scarano, Antonio
    MATERIALS, 2020, 13 (23) : 1 - 19
  • [10] Breast Cancer Trials biobank: Clinically annotated specimens for translational research
    Zdenkowski, Nicholas
    Badger, Heath
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2021, 17 : 22 - 23