A study on the effect of flaw detection probability assumptions on risk reduction achieved by non-destructive inspection

被引:12
|
作者
Cronvall, O. [1 ]
Simola, K. [1 ]
Mannisto, I. [1 ]
Gunnars, J. [2 ]
Alverlind, L. [2 ]
Dillstrom, P. [2 ]
Gandossi, L. [3 ]
机构
[1] VTT, Tech Res Ctr Finland, Espoo 02044, Finland
[2] Inspecta Technol AB, Stockholm, Sweden
[3] Joint Res Ctr, Inst Energy, NL-1755 ZG Petten, Netherlands
关键词
Inspection reliability; Probability of detection curves (POD); Risk-informed in-service inspection; Probabilistic fracture mechanics (PFM); BREAK; IGSCC;
D O I
10.1016/j.ress.2012.03.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Leakages and ruptures of piping components lead to reduction or loss of the pressure retaining capability of the system, and thus contribute to the overall risk associated with nuclear power plants. In-service inspection (ISI) aims at verifying that defects are not present in components of the pressure boundary or, if defects are present, ensuring that these are detected before they affect the safe operation of the plant. Reliability estimates of piping are needed e.g., in probabilistic safety assessment (PSA) studies, risk-informed ISI (RI-ISI) applications, and other structural reliability assessments. Probabilistic fracture mechanics models can account for ISI reliability, but a quantitative estimate for the latter is needed. This is normally expressed in terms of probability of detection (POD) curves, which correlate the probability of detecting a flaw with flaw size. A detailed POD curve is often difficult (or practically impossible) to obtain. If sufficient risk reduction can be shown by using simplified (but reasonably conservative) POD estimates, more complex PODs are not needed. This paper summarises the results of a study on the effect of piping inspection reliability assumptions on failure probability using structural reliability models. The main interest was to investigate whether it is justifiable to use a simplified POD curve. Further, the study compared various structural reliability calculation approaches for a set of analysis cases. The results indicate that the use of a simplified POD could be justifiable in RI-ISI applications. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [1] Probability of detection model for the non-destructive inspection of steam generator tubes of PWRs
    Yusa, N.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016, 2017, 860
  • [2] Theory of non-destructive inspection of ceramics based on flaw-size distribution
    Matsuo, Yohtaro
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2008, 22 (9-11): : 1489 - 1495
  • [3] ULTRASONIC FLAW DETECTION AND SIZING FOR QUANTITATIVE NON-DESTRUCTIVE EVALUATION
    DEFACIO, B
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 413 : 48 - 55
  • [4] A Study on the Scan Plans for Rapid Flaw Detection by Eddy Current Non-Destructive Evaluation
    Soni, Anil Kumar
    Mahadevan, S.
    Thirunavukkarasu, S.
    Rao, B. Purna Chandra
    IETE JOURNAL OF RESEARCH, 2023, 69 (10) : 7260 - 7271
  • [5] Reflective fringe pattern technique for non-destructive subsurface flaw detection
    Chan, F. W. Y.
    INSIGHT, 2008, 50 (10) : 579 - 585
  • [6] Study on non-destructive inspection technology of seal packaging
    Gao, XB
    Yin, ZD
    Zhang, Y
    Zhang, L
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 4925 - 4927
  • [7] Carbon fiber reinforced concrete for smart structures capable of non-destructive flaw detection
    Chen, Pu-Woei
    Chung, D.D.L.
    Smart Materials and Structures, 1993, 2 (01)
  • [8] Ultrasonic flaw detection using partial wavelet in offshore pipeline non-destructive evaluation
    Wei, L.
    Liang, C.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [9] INDUCTIVE CURRENT FLAW DETECTOR FOR NON-DESTRUCTIVE DETECTION OF CRACKS IN BARS AND STEEL WIRES
    SOLNICA, W
    LEWINSKAROMICKA, A
    PISKORSKI, S
    OWSIANY, M
    MECHANIK MIESIECZNIK NAUKOWO-TECHNICZNY, 1981, 54 (10-1): : 489 - 491
  • [10] A fretting fatigue crack detection feasibility study using shear wave non-destructive inspection
    A. L. Hutson
    D. Stubbs
    Experimental Mechanics, 2005, 45 (2) : 160 - 166