Large, Single-Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical Dilatation

被引:36
|
作者
Di Cori, Andrea [1 ]
Bongiorni, Maria Grazia [1 ]
Zucchelli, Giulio [1 ]
Segreti, Luca [1 ]
Viani, Stefano [1 ]
De Lucia, Raffaele [1 ]
Paperini, Luca [1 ]
Soldati, Ezio [1 ]
机构
[1] Hosp Univ Pisa, New Santa Chiara Hosp, Cardiac & Thorac Dept, Div Cardiovasc Dis 2, I-56100 Pisa, Italy
来源
关键词
resynchronization therapy; transvenous lead extraction; coronary sinus lead; DEFIBRILLATOR LEADS; PACEMAKER LEADS; SAFETY; VEIN; FIXATION; SHEATH;
D O I
10.1111/j.1540-8159.2011.03273.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to evaluate procedural outcomes of coronary sinus (CS) lead extraction, focusing on predictors and need for mechanical dilatation (MD) in the event that manual traction (MT) is ineffective. Methods: The study assessed results in 145 consecutive patients (age 69 +/- 10 years; 121 men)-a total of 147 CS pacing leads-who underwent transvenous CS lead removal between January 2000 and March 2010. Results: All leads but one (99%) (implantation time 29 +/- 25 months) were successfully removed. MT was effective in 103 (70%), and MD was necessary in the remaining 44 (30%) procedures. In multivariate analyses, unipolar design (odds ratio [OR] 3.22, 95% confidence interval [CI] 1.43-7.7; P = 0.005) and noninfective indication (OR 4.8, 95% CI 1.8-13, P = 0.002) were independent predictors for MD (P < 0.0001), with a predictive trend for prior cardiac surgery (OR 2.2, 95% CI 0.98-5.26; P = 0.06). Five (3.4%) complex procedures required a transfemoral vein approach (TFA) or repeat procedure. No deaths occurred, and there was one major complication (0.7%), cardiac tamponade, after MT. No complication predictors were identified. Conclusions: CS leads were safely and effectively removed in nearly all patients, and 70% were removed with MT alone; 30% required MD. Preoperative predictors suggesting the need for MD or TFA were noninfective indication and unipolar lead design. Complications were rare, and there was no predictable pattern among MT or MD removal techniques. (PACE 2012; 35:215-222)
引用
收藏
页码:215 / 222
页数:8
相关论文
共 50 条
  • [1] LARGE SINGLE CENTER EXPERIENCE IN TRANSVENOUS CORONARY SINUS LEAD REMOVAL: PROCEDURAL OUTCOMES AND PREDICTORS OF MECHANICAL DILATATION
    Di Cori, A.
    Zucchelli, G.
    Soldati, E.
    Segreti, L.
    De Lucia, R.
    Viani, S.
    Paperini, L.
    Bongiorni, M. G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S137 - S137
  • [2] Transvenous coronary sinus lead extraction: procedural outcomes and predictors of mechanical dilatation
    Di Cori, A.
    Zucchelli, G.
    Soldati, E.
    Segreti, L.
    De Lucia, R.
    Viani, S.
    Fabiani, I.
    Paperini, L.
    Bongiorni, M. G.
    EUROPEAN HEART JOURNAL, 2011, 32 : 177 - 177
  • [3] Indications for transvenous lead extraction and its procedural and early outcomes in elderly patients: a single-center experience
    Zabek, Andrzej
    Boczar, Krzysztof
    Debskil, Maciej
    Pfitzner, Roman
    Ulmanl, Mateusz
    Holcman, Katarzyna
    Kostkiewicz, Magdalena
    Musial, Robert
    Lelakowski, Jacek
    Malecka, Barbara
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2020, 130 (03): : 216 - 224
  • [4] Outcomes of transvenous lead extraction in patients with lead perforation: A single-center experience
    Zhou, Xu
    Ze, Feng
    Li, Ding
    Wang, Long
    Guo, Jihong
    Li, Xuebin
    CLINICAL CARDIOLOGY, 2020, 43 (04) : 386 - 393
  • [5] Extraction of Coronary Sinus Lead: A Large Single Center Experience
    Carrillo, Roger G.
    Garisto, Juan D.
    CIRCULATION, 2010, 122 (21)
  • [6] Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications
    Jones, Samuel O.
    Eckart, Robert E.
    Albert, Christine M.
    Epstein, Laurence M.
    HEART RHYTHM, 2008, 5 (04) : 520 - 525
  • [7] Safety and Efficacy of Transvenous Lead Extraction Utilizing the Evolution Mechanical Lead Extraction System A Single-Center Experience
    Sharma, Saumya
    Ekeruo, Ijeoma A.
    Nand, Nikita P.
    Raman, Ajay Sundara
    Zhang, Xu
    Reddy, Sunil K.
    Hariharan, Ramesh
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 212 - 220
  • [8] The complications of lead extraction with infected vegetations: a single-center experience and consequences of transvenous extraction
    Nagashima, M.
    Goya, M.
    Soga, Y.
    Hiroshima, K.
    Andou, K.
    Iwabuchi, M.
    Yokoi, H.
    Nobuyoshi, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 796 - 796
  • [9] Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
    Migliore, Federico
    Pittorru, Raimondo
    De Lazzari, Manuel
    Tarzia, Vincenzo
    Pastore, Gianni
    Marcantoni, Lina
    Catanzariti, Domenico
    Gerosa, Gino
    Zanon, Francesco
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (01) : 175 - 182
  • [10] Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experience
    Federico Migliore
    Raimondo Pittorru
    Manuel De Lazzari
    Vincenzo Tarzia
    Gianni Pastore
    Lina Marcantoni
    Domenico Catanzariti
    Gino Gerosa
    Francesco Zanon
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 175 - 182