Rapid assessment of perfusion-diffusion mismatch

被引:63
作者
Butcher, Ken [1 ,3 ]
Parsons, Mark [5 ]
Allport, Louise [1 ]
Lee, Sang Bong [4 ]
Barber, P. Alan
Tress, Brian [2 ]
Donnan, Geoffrey A. [6 ]
Davis, Stephen M. [1 ]
机构
[1] Univ Melbourne, Royal Melbourne Hosp, Dept Neurol, Melbourne, Vic 3050, Australia
[2] Univ Melbourne, Royal Melbourne Hosp, Dept Radiol, Melbourne, Vic 3050, Australia
[3] Univ Alberta, Dept Neurol, Edmonton, AB, Canada
[4] Catholic Univ Korea, Dept Neurol, Seoul, South Korea
[5] John Hunter Hosp, Dept Neurol, Newcastle, NSW, Australia
[6] Austin Hosp, Dept Neurol, Melbourne, Vic 3084, Australia
关键词
brain imaging; cerebral blood flow; cerebral infarct; diffusion-weighted imaging; perfusion-weighed imaging;
D O I
10.1161/STROKEAHA.107.490524
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. Methods-DWI and PWI were performed in 35 patients with stroke < 6 hours after symptom onset. DWI lesion and PWI (time to peak) volumes were measured with planimetric techniques by 4 raters and the 95% limits of agreement calculated. ASPECT scores were assessed separately by 4 investigators (2 experienced and 2 inexperienced) for DWI (MR DWI scores) and PWI (MR time to peak scores). MR mismatch scores were calculated as MR DWI-MR time to peak scores. Results-Interobserver variability was much greater for PWI (95% limit of agreement=+/- 72.3 mL) than for DWI (95% limit of agreement=+/- 12.6 mL). A semiautomated PWI volume (time to peak + 2 s) was therefore used to calculate mismatch volume. MR mismatch scores >= 2 predicted 20% PWI-DWI mismatch by volume with mean 78% sensitivity (range, 72% to 84%) and 88% specificity (range, 83% to 90%). There was excellent agreement on mismatch classification using MR mismatch scores between experienced raters (weighted kappa scores of 0.94) with agreement in 34 of 35 cases. Agreement was less consistent between inexperienced raters (weighted kappa=0.49, 28 of 35 cases). Conclusions-Variability in planimetric mismatch measurements arises primarily from differences in PWI volume assessment. High specificity and interrater reliability may make MR mismatch scores an ideal rapid screening tool for potential thrombolysis patients.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 24 条
[1]   Magnetic resonance imaging profiles predict clinical response to early reperfusion: The diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) study [J].
Albers, Gregory W. ;
Thijs, Vincent N. ;
Wechsle, Lawrence ;
Kemp, Stephanie ;
Schlaug, Gottfried ;
Skalabrin, Elaine ;
Bammer, Roland ;
Kakuda, Wataru ;
Lansberg, Maarten G. ;
Shuaib, Ashfaq ;
Coplin, William ;
Hamilton, Scott ;
Moseley, Michael ;
Marks, Michael P. .
ANNALS OF NEUROLOGY, 2006, 60 (05) :508-517
[2]   Enlargement of human cerebral ischemic lesion volumes measured by diffusion-weighted magnetic resonance imaging [J].
Baird, AE ;
Benfield, A ;
Schlaug, G ;
Siewert, B ;
Lovblad, KO ;
Edelman, RR ;
Warach, S .
ANNALS OF NEUROLOGY, 1997, 41 (05) :581-589
[3]   Imaging of the brain in acute ischaemic stroke: comparison of computed tomography and magnetic resonance diffusion-weighted imaging [J].
Barber, PA ;
Hill, MD ;
Eliasziw, M ;
Demchuk, AM ;
Pexman, JHW ;
Hudon, ME ;
Tomanek, A ;
Frayne, R ;
Buchan, AM .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2005, 76 (11) :1528-1533
[4]   Identification of major ischemic change - Diffusion-weighted imaging versus computed tomography [J].
Barber, PA ;
Darby, DG ;
Desmond, PM ;
Gerraty, RP ;
Yang, Q ;
Li, T ;
Jolley, D ;
Donnan, GA ;
Tress, BM ;
Davis, SM .
STROKE, 1999, 30 (10) :2059-2065
[5]   Validity and reliability of a quantitative computed tomography score in predicting outcome of hyperacute stroke before thrombolytic therapy [J].
Barber, PA ;
Demchuk, AM ;
Zhang, JJ ;
Buchan, AM .
LANCET, 2000, 355 (9216) :1670-1674
[6]   Prediction of stroke outcome with echoplanar perfusion- and diffusion-weighted MRI [J].
Barber, PA ;
Darby, DG ;
Desmond, PM ;
Yang, Q ;
Gerraty, RP ;
Jolley, D ;
Donnan, GA ;
Tress, BM ;
Davis, SM .
NEUROLOGY, 1998, 51 (02) :418-426
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Refining the perfusion-diffusion mismatch hypothesis [J].
Butcher, KS ;
Parsons, M ;
MacGregor, L ;
Barber, PA ;
Chalk, J ;
Bladin, C ;
Levi, C ;
Kimber, T ;
Schultz, D ;
Fink, J ;
Tress, B ;
Donnan, G ;
Davis, S .
STROKE, 2005, 36 (06) :1153-1159
[9]   ASPECTS on CTA source images versus unenhanced CT - Added value in predicting final infarct extent and clinical outcome [J].
Coutts, SB ;
Lev, MH ;
Eliasziw, M ;
Roccatagliata, L ;
Hill, MD ;
Schwamm, LH ;
Pexman, JHW ;
Koroshetz, WJ ;
Hudon, ME ;
Buchan, AM ;
Gonzalez, RG ;
Demchuk, AM .
STROKE, 2004, 35 (11) :2472-2476
[10]   Interobserver variation of ASPECTS in real time [J].
Coutts, SB ;
Demchuk, AM ;
Barber, PA ;
Hu, WY ;
Simon, JE ;
Buchan, AM ;
Hill, MD .
STROKE, 2004, 35 (05) :E103-E105