Evaluation of coma aberration in projection lens by various measurements

被引:11
|
作者
Saito, T [1 ]
Watanabe, H [1 ]
Okuda, Y [1 ]
机构
[1] Matsushita Elect Corp, ULSI Proc Technol Dev Ctr, Minami Ku, Kyoto 6018413, Japan
来源
OPTICAL MICROLITHOGRAPHY XI | 1998年 / 3334卷
关键词
coma aberration; image quality; pattern asymmetry; feature size; de-centering coma aberration; side lobe;
D O I
10.1117/12.310759
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, evaluation of lens coma aberration in projection lens of a stepper by various measurement methods is described. The measurement methods were based on asymmetry of the printed images caused by coma aberration. We used three measurement methods. They are conventionally used method and two new methods. The three methods are: (a) measuring the CD difference between both ends of line-and-space, (b) observing the side lobe patterns using an attenuated phase shifting mask (a-PSM), and (c) measuring the registration error using overlay patterns that have assist patterns. These measurement patterns are printed on Si wafers by a KrF stepper (NA=0.55) with various sigma. The dependence of the feature size and sigma on the influence of coma aberration was easily measured by these methods. As each method has merits and demerits, proper use of each method is necessary. Then the influence of coma aberration was evaluated by method (a). The influence of coma aberration had two components and they were due to primary coma aberration and de-centering coma aberration respectively. We estimated the influence of coma aberration by simulation and got good agreement with the experimental results. The measurement methods we demonstrated here are applicable for lens evaluation of steppers by the users.
引用
收藏
页码:297 / 308
页数:4
相关论文
共 50 条
  • [1] Thermal aberration control in projection lens
    Nakashima, Toshiharu
    Ohmura, Yasuhiro
    Ogata, Taro
    Uehara, Yusaku
    Nishinaga, Hisashi
    Matsuyama, Tomoyuki
    OPTICAL MICROLITHOGRAPHY XXI, PTS 1-3, 2008, 6924
  • [2] ON THE CHROMATIC ABERRATION OF THE MAGNETIC PROJECTION LENS
    MORITO, N
    JOURNAL OF ELECTRON MICROSCOPY, 1957, 5 : 1 - 2
  • [3] A novel method to measure coma aberration of projection system
    Ma, Mingying
    Wang, Xiangzhao
    Wang, Fan
    OPTIK, 2006, 117 (11): : 532 - 536
  • [4] Effect of intraocular lens asphericity on vertical coma aberration
    Nanavaty, Mayank A.
    Spalton, David J.
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 215 - 221
  • [5] The thermal aberration analysis of a lithography projection lens
    Mao, Yanjie
    Li, Sikun
    Sun, Gang
    Wang, Jian
    Duan, Lifeng
    Bu, Yang
    Wang, Xiangzhao
    OPTICAL MICROLITHOGRAPHY XXX, 2017, 10147
  • [6] Wavefront aberration compensation of projection lens using clocking lens elements
    Liu, ChunLai
    Huang, Wei
    Shi, Zhenguang
    Xu, Weicai
    APPLIED OPTICS, 2013, 52 (22) : 5398 - 5401
  • [7] General method for replacing a thin lens with a thick lens with the same value of Seidel aberration coefficient of spherical aberration or coma
    Miks, Antonin
    Novak, Pavel
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2021, 38 (09) : 1372 - 1379
  • [8] General method for replacing a thin lens with a thick lens with the same value of Seidel aberration coefficient of spherical aberration or coma
    Mikš, Antonín
    Novák, Pavel
    Novák, Pavel (pavel.novak.3@fsv.cvut.cz), 1600, The Optical Society (38): : 1372 - 1379
  • [9] Optimizing correction of coma aberration in keratoconus with a novel soft contact lens
    Suzaki, Asaki
    Koh, Shizuka
    Maeda, Naoyuki
    Asonuma, Sanae
    Santodomingo-Rubido, Jacinto
    Oie, Yoshinori
    Soma, Takeshi
    Fujikado, Takashi
    Nishida, Kohji
    CONTACT LENS & ANTERIOR EYE, 2021, 44 (04):
  • [10] Perturbative analysis of partially coherent illumination for coma aberration measurements
    Yashiki, Satoshi
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2015, 32 (04) : 669 - 677