Intra-operative subcortical electrical stimulation: A comparison of two methods

被引:87
|
作者
Szelenyi, A. [1 ]
Senft, C. [1 ]
Jardan, M. [1 ]
Forster, M. T. [1 ]
Franz, K. [1 ]
Seifert, V. [1 ]
Vatter, H. [1 ]
机构
[1] Johann Wolfgang Goethe Univ Hosp, Dept Neurosurg, D-60528 Frankfurt, Germany
关键词
Direct cortical stimulation; Bipolar stimulation; Monopolar stimulation; Multipulse technique; 50-Hz stimulation; Subcortical; Glioma surgery; MOTOR EVOKED-POTENTIALS; LOW-GRADE GLIOMAS; ANESTHETIZED HUMANS; SURGICAL REMOVAL; SURGERY; CORTEX; RESECTION; PATHWAYS; PARAMETERS; ELECTRODE;
D O I
10.1016/j.clinph.2010.12.055
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: For intra-operative subcortical electrical stimulation of the corticospinal tract, two techniques - originally described for cortical stimulation - have evolved: the 50-Hz-stimulation first described by Penfield in 1937 and the high-frequency multipulse train stimulation technique first described by Taniguchi in 1993. Motor thresholds of both methods in combination with a bipolar and monopolar stimulation technique and their reliability for eliciting motor evoked potentials (MEPs) were studied. Methods: Data were obtained in 20 patients (50 +/- 17 years; 10 females) undergoing tumour resection under general anaesthesia. Both 50-Hz-stimulation of 1-s duration and a multipulse stimulation (5 pulses interstimulus interval 4 ms, 0.5-Hz repetition rate) were applied with a bipolar probe (1.5-mm ball tip, 8-mm interelectrode distance) and a monopolar probe (1.5-mm-diameter tip). MEPs were recorded in muscles contralateral to the stimulated hemisphere. Comparison of different stimulation modalities was performed at the site where monopolar multipulse stimulation technique elicited MEPs with the lowest stimulation intensity (constant current monophasic cathodal stimulation, individual pulse width 0.5 ms, max. 25 mA). Results: MEPs were elicited by monopolar multipulse stimulation with an intensity of 8 +/- 3.9 mA (21/21 stimulation sites); monopolar 50-Hz stimulation with 12 +/- 5.4 mA (18/21 stimulation sites); bipolar multipulse stimulation with 14 +/- 8.1 mA (12/21 stimulation sites) and bipolar 50-Hz stimulation with 15 +/- 6.3 mA (11/21 stimulation sites). Conclusions: Stimulation intensities for eliciting MEPs are significantly lowest for the monopolar multipulse stimulation (p < 0.025). Monopolar compared to bipolar stimulation resulted in eliciting MEPs in a higher number of tested patients (Fisher's p < 0.0001). Significance: Subcortical stimulation with a monopolar probe and a multipulse stimulation is most efficient for the purpose of identifying the corticospinal tract. This is explained by the more radiant electric field properties of the monopolar probe compared to the bipolar probe. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1470 / 1475
页数:6
相关论文
共 50 条
  • [1] Intra-operative mapping of the subcortical visual pathways using direct electrical stimulations
    H. Duffau
    S. Velut
    M.-C. Mitchell
    P. Gatignol
    L. Capelle
    Acta Neurochirurgica, 2004, 146 : 265 - 270
  • [2] Intra-operative mapping of the subcortical visual pathways using direct electrical stimulations
    Duffau, H
    Velut, S
    Mitchell, MC
    Gatignol, P
    Capelle, L
    ACTA NEUROCHIRURGICA, 2004, 146 (03) : 265 - 270
  • [4] INTRA-OPERATIVE POINT OF CARE HAEMOGLOBIN ESTIMATION: A COMPARISON OF THREE METHODS
    Srinivasan, Nataraj Madagondapalli
    Kasturba, Manjunath Prabhu
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2010, 18 (01): : 15 - 19
  • [5] Integrated datasets of normalized brain with functional localization using intra-operative electrical stimulation
    Tamura, Manabu
    Sato, Ikuma
    Maruyama, Takashi
    Ohshima, Kazuma
    Mangin, Jean-Francois
    Nitta, Masayuki
    Saito, Taiichi
    Yamada, Hiroyuki
    Minami, Shinji
    Masamune, Ken
    Kawamata, Takakazu
    Iseki, Hiroshi
    Muragaki, Yoshihiro
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (12) : 2109 - 2122
  • [6] Integrated datasets of normalized brain with functional localization using intra-operative electrical stimulation
    Manabu Tamura
    Ikuma Sato
    Takashi Maruyama
    Kazuma Ohshima
    Jean-François Mangin
    Masayuki Nitta
    Taiichi Saito
    Hiroyuki Yamada
    Shinji Minami
    Ken Masamune
    Takakazu Kawamata
    Hiroshi Iseki
    Yoshihiro Muragaki
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 2109 - 2122
  • [8] Pediatric awake craniotomy and intra-operative stimulation mapping
    Balogun, James A.
    Khan, Osaama H.
    Taylor, Michael
    Dirks, Peter
    Der, Tara
    Snead, O. Carter, III
    Weiss, Shelly
    Ochi, Ayako
    Drake, James
    Rutka, James T.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (11) : 1891 - 1894
  • [9] THE ELECTRICAL-STIMULATION TEST FOR INTRA-OPERATIVE VAGOTOMY CONTROL - RESULTS OF A PROSPECTIVE RANDOMIZED STUDY
    JUNGINGER, T
    RAAB, M
    PICHLMAIER, H
    CHIRURG, 1981, 52 (08): : 519 - 524
  • [10] Transcranial electrical stimulation: significance of fast versus slow charge delivery for intra-operative monitoring
    Hausmann, ON
    Min, K
    Boos, N
    Ruetsch, YA
    Erni, T
    Curt, A
    CLINICAL NEUROPHYSIOLOGY, 2002, 113 (10) : 1532 - 1535