A numerical study of the nozzle/diffuser micropump

被引:11
|
作者
Yang, K-S [1 ]
Chen, I-Y [2 ]
Chien, K-H [1 ]
Wang, C-C [1 ]
机构
[1] Ind Technol Res Inst, Energy & Environm Labs, Hsinchu 310, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Grad Sch Engn Sci & Technol, Yunlin, Taiwan
关键词
micropump; computational fluid dynamics; valve-less; VALVE-LESS PUMP; SILICON-WAFER; PERFORMANCE; MODEL;
D O I
10.1243/09544062JMES473
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study numerically investigates the performance of micronozzle/diffuser pump subject to the influence of frequency, opening angle, geometric dimension, and amplitude. For the effect of geometric dimension, the effect of chamber length is far more important than that of chamber depth because it can provide much more effective pumping volume. It is found that the net flowrate of a micropump increased with pumping frequency and opening angle. However, a level-off phenomenon of the net flowrate versus amplitude is seen at amplitudes nearby 150-200 mu m and at an opening angle above 10 degrees. This phenomenon is associated with two factors that compensate with each other. One is the free jet flow from the outlet that overturns and blocks the flow from the inlet. The other is the reduction of the strength of jet flow at a larger amplitude owing to effective increase of cross-sectional area.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 50 条
  • [1] A thin PDMS nozzle/diffuser micropump for biomedical applications
    Kawun, Paul
    Leahy, Stephane
    Lai, Yongjun
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 249 : 149 - 154
  • [2] Simulation and Fabrication of Piezoelectrically Actuated Nozzle/Diffuser Micropump
    Bhattacharjee, Sumana
    Mishra, Rishabh Bhooshan
    Devendra, Deeksha
    Hussain, Aftab M.
    2019 IEEE SENSORS, 2019,
  • [3] Piezoelectric diffuser/nozzle micropump with double pump chambers
    Wang W.
    Zhang Y.
    Tian L.
    Chen X.
    Liu X.
    Frontiers of Mechanical Engineering in China, 2008, 3 (4): : 449 - 453
  • [4] Pumping of mammalian cells with a nozzle-diffuser micropump
    Yamahata, C
    Vandevyver, C
    Lacharme, F
    Izewska, P
    Vogel, H
    Freitag, R
    Gijs, MAM
    LAB ON A CHIP, 2005, 5 (10) : 1083 - 1088
  • [5] Novel diffuser-nozzle micropump actuated by thermal bubble
    Rahman, MA
    Ahmed, F
    Zhao, Y
    Gong, TH
    SMART STRUCTURES AND MATERIALS 2000: SMART ELECTRONICS AND MEMS, 2000, 3990 : 232 - 245
  • [6] A numerical study of the nozzle/diffuser micro-pump
    Yang, KS
    Chen, IY
    Chien, KH
    Wang, CC
    2004 INTERNATIONAL CONFERENCE ON MEMS, NANO AND SMART SYSTEMS, PROCEEDINGS, 2004, : 104 - 109
  • [7] Flow characteristics of the diffuser/nozzle micropump-A state space approach
    Chandika, S.
    Asokan, R.
    Vijayakumar, K. C. K.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 28 : 28 - 34
  • [8] PUMP HEAD IMPROVEMENT OF DIFFUSER/NOZZLE VALVE-LESS MICROPUMP
    Tanaka, Seiichi
    Miyazaki, Koji
    Fujiwara, Seiji
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2013, 2013,
  • [9] Development of a diffuser/nozzle type micropump based on magnetohydrodynamic (MHD) principle
    Heng, KH
    Huang, L
    Wang, WJ
    Murphy, MC
    MICROFLUIDIC DEVICES AND SYSTEMS II, 1999, 3877 : 66 - 73
  • [10] A Novel Piezoelectric Valveless Micropump with an Integrated Diffuser/Nozzle Bulge Piece Design
    Chan, Tsung-Hsing
    Cheng, Chiang-Ho
    Yang, An-Shik
    Tseng, Li-Yu
    NEMS/MEMS TECHNOLOGY AND DEVICES, 2009, 74 : 227 - +