Atmospheric Extinction in Simulation Tools for Solar Tower Plants

被引:2
|
作者
Hanrieder, Natalie [1 ]
Wilbert, Stefan [1 ]
Schroedter-Homscheidt, Marion [2 ]
Schnell, Franziska [2 ]
Guevara, Diana Mancera [2 ]
Buck, Reiner [3 ]
Giuliano, Stefano [3 ]
Pitz-Paal, Robert [4 ]
机构
[1] German Aerosp Ctr DLR, PSA, Inst Solar Res, Ctra Senes S-N Km 4,Apartado 39, Tabernas 04200, Spain
[2] German Aerosp Ctr DLR, Remote Sensing Data Ctr DFD, D-82234 Wessling, Germany
[3] German Aerosp Ctr DLR, Inst Solar Res, Pfaffenwaldring 38-40, D-70569 Stuttgart, Germany
[4] German Aerosp Ctr DLR, Inst Solar Res, D-51147 Cologne, Germany
关键词
RADIATION ATTENUATION;
D O I
10.1063/1.4984519
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Atmospheric extinction causes significant radiation losses between the heliostat field and the receiver in a solar tower plants. These losses vary with site and time. State of the art is that in ray-tracing and plant optimization tools, atmospheric extinction is included by choosing between few constant standard atmospheric conditions. Even though some tools allow the consideration of site and time dependent extinction data, such data sets are nearly never available. This paper summarizes and compares the most common model equations implemented in several ray-tracing tools. There are already several methods developed and published to measure extinction on-site. An overview of the existing methods is also given here. Ray-tracing simulations of one exemplary tower plant at the Plataforma Solar de Almeria (PSA) are presented to estimate the plant yield deviations between simulations using standard model equations instead of extinction time series. For PSA, the effect of atmospheric extinction accounts for losses between 1.6 and 7 %. This range is caused by considering overload dumping or not. Applying standard clear or hazy model equations instead of extinction time series lead to an underestimation of the annual plant yield at PSA. The discussion of the effect of extinction in tower plants has to include overload dumping. Situations in which overload dumping occurs are mostly connected to high radiation levels and low atmospheric extinction. Therefore it can be recommended that project developers should consider site and time dependent extinction data especially on hazy sites. A reduced uncertainty of the plant yield prediction can significantly reduce costs due to smaller risk margins for financing and EPCs. The generation of extinction data for several locations in form of representative yearly time series or geographical maps should be further elaborated.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Atmospheric extinction in solar tower plants - A review
    Hanrieder, N.
    Wilbert, S.
    Mancera-Guevara, D.
    Buck, R.
    Giuliano, S.
    Pitz-Paal, R.
    SOLAR ENERGY, 2017, 152 : 193 - 207
  • [2] Atmospheric extinction in solar tower plants: absorption and broadband correction for MOR measurements
    Hanrieder, N.
    Wilbert, S.
    Pitz-Paal, R.
    Emde, C.
    Gasteiger, J.
    Mayer, B.
    Polo, J.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (08) : 3467 - 3480
  • [3] Measurement of Solar Extinction in Tower Plants with Digital Cameras
    Ballestrin, J.
    Monterreal, R.
    Carra, M. E.
    Fernandez-Reche, J.
    Barbero, J.
    Marzo, A.
    SOLARPACES 2015: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2016, 1734
  • [4] World map of low-layer atmospheric extinction values for solar power tower plants projects
    Salmon, Alois
    Marzo, Aitor
    Polo, Jesus
    Ballestrin, Jesus
    Carra, Elena
    Alonso-Montesinos, Joaquin
    RENEWABLE ENERGY, 2022, 201 : 876 - 888
  • [5] Atmospheric extinction of solar radiation measurement in solar thermal electric plants
    Carra, M. E.
    Ballestrin, J.
    Barbero, J.
    OPTICA PURA Y APLICADA, 2021, 54 (02): : 1 - 11
  • [6] Atmospheric horizontal extinction determined with a single digital camera-based system in the scope of solar power tower plants
    Barbero, F. J.
    Alonso-Montesinos, J.
    Ballestrin, J.
    Carra, M. E.
    Fernandez-Reche, J.
    MEASUREMENT, 2020, 149
  • [7] Modeling and simulation of solar tower thermal plants receiver
    Li K.
    Song P.
    Wang J.
    Jiang C.
    Li J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (07): : 193 - 198
  • [8] Simulation and exergy analysis of solar thermal tower plants
    Xu, Ershu
    Hu, Zhongliang
    Zhai, Rongrong
    Wang, Bei
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (11): : 1799 - 1806
  • [9] Solar extinction measurement system based on digital cameras. Application to solar tower plants
    Ballestrin, J.
    Monterreal, R.
    Carra, M. E.
    Fernandez-Reche, J.
    Polo, J.
    Enrique, R.
    Rodriguez, J.
    Casanova, M.
    Barbero, F. J.
    Alonso-Montesinos, J.
    Lopez, G.
    Bosch, J. L.
    Batlles, F. J.
    Marzo, A.
    RENEWABLE ENERGY, 2018, 125 : 648 - 654
  • [10] Modeling solar extinction using artificial neural networks. Application to solar tower plants
    Ballestrin, J.
    Carra, E.
    Alonso-Montesinos, J.
    Lopez, G.
    Polo, J.
    Marzo, A.
    Fernandez-Reche, J.
    Barbero, J.
    Batlles, F. J.
    ENERGY, 2020, 199