Measurement of Regional 2D Gas Transport Efficiency in Rabbit Lung Using Hyperpolarized 129Xe MRI

被引:5
|
作者
Ruppert, Kai [1 ]
Xin, Yi [1 ,2 ]
Hamedani, Hooman [1 ,2 ]
Amzajerdian, Faraz [1 ,2 ]
Loza, Luis [1 ]
Achekzai, Tahmina [1 ]
Duncan, Ian F. [1 ]
Profka, Harrilla [1 ]
Siddiqui, Sarmad [1 ,2 ]
Pourfathi, Mehrdad [1 ,3 ]
Sertic, Federico [1 ]
Cereda, Maurizio F. [4 ]
Kadlecek, Stephen [1 ]
Rizi, Rahim R. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Elect & Syst Engn, Philadelphia, PA 19104 USA
[4] Univ Penn, Dept Anesthesiol & Crit Care, Philadelphia, PA 19104 USA
关键词
PULMONARY PERFUSION; XE-129; EXCHANGE; SPECTROSCOPY; VENTILATION; NMR;
D O I
10.1038/s41598-019-38942-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
While hyperpolarized xenon-129 (HXe) MRI offers a wide array of tools for assessing functional aspects of the lung, existing techniques provide only limited quantitative information about the impact of an observed pathology on overall lung function. By selectively destroying the alveolar HXe gas phase magnetization in a volume of interest and monitoring the subsequent decrease in the signal from xenon dissolved in the blood inside the left ventricle of the heart, it is possible to directly measure the contribution of that saturated lung volume to the gas transport capacity of the entire lung. In mechanically ventilated rabbits, we found that both xenon gas transport and transport efficiency exhibited a gravitation-induced anterior-to-posterior gradient that disappeared or reversed direction, respectively, when the animal was turned from supine to prone position. Further, posterior ventilation defects secondary to acute lung injury could be re-inflated by applying positive end expiratory pressure, although at the expense of decreased gas transport efficiency in the anterior volumes. These findings suggest that our technique might prove highly valuable for evaluating lung transplants and lung resections, and could improve our understanding of optimal mechanical ventilator settings in acute lung injury.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Measurement of Regional 2D Gas Transport Efficiency in Rabbit Lung Using Hyperpolarized 129Xe MRI
    Kai Ruppert
    Yi Xin
    Hooman Hamedani
    Faraz Amzajerdian
    Luis Loza
    Tahmina Achekzai
    Ian F. Duncan
    Harrilla Profka
    Sarmad Siddiqui
    Mehrdad Pourfathi
    Federico Sertic
    Maurizio F. Cereda
    Stephen Kadlecek
    Rahim R. Rizi
    Scientific Reports, 9
  • [2] Hyperpolarized 129Xe MRI of the human lung
    Mugler, John P.
    Altes, Talissa A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) : 313 - 331
  • [3] MRI of stroke using hyperpolarized 129Xe
    Zhou, Xin
    Sun, Yanping
    Mazzanti, Mary
    Henninger, Nils
    Mansour, Joey
    Fisher, Marc
    Albert, Mitchell
    NMR IN BIOMEDICINE, 2011, 24 (02) : 170 - 175
  • [4] Preclinical MRI Using Hyperpolarized 129Xe
    Kadlecek, Stephen
    Friedlander, Yonni
    Virgincar, Rohan S.
    MOLECULES, 2022, 27 (23):
  • [5] Diffusion weighted hyperpolarized 129Xe MRI of the lung with 2D and 3D (FLORET) spiral
    Bdaiwi, Abdullah S.
    Willmering, Matthew M.
    Wang, Hui
    Cleveland, Zackary, I
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1342 - 1356
  • [6] Hyperpolarized 129Xe MRI using isobutene as a new quenching gas
    Hodono, Shota
    Imai, Hirohiko
    Yamauchi, Yukiko
    Kawamura, Ayano
    Matsumoto, Hironobu
    Okumura, Shintaro
    Fujiwara, Hideaki
    Kimura, Atsuomi
    NMR IN BIOMEDICINE, 2016, 29 (10) : 1414 - 1419
  • [7] Hyperpolarized 129Xe MRI using gas-filled liposomes
    Venkatesh, AK
    Zhao, L
    Balamore, D
    Jolesz, FA
    Albert, MS
    ACADEMIC RADIOLOGY, 2002, 9 : S270 - S274
  • [8] Using hyperpolarized 129Xe MRI to quantify regional gas transfer in idiopathic pulmonary fibrosis
    Wang, Jennifer M.
    Robertson, Scott H.
    Wang, Ziyi
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Smigla, Rose Marie
    O'Riordan, Thomas G.
    Sundy, John
    Ebner, Lukas
    Rackley, Craig R.
    McAdams, Page
    Driehuys, Bastiaan
    THORAX, 2018, 73 (01) : 21 - 28
  • [9] Mapping Regional Pediatric Interstitial Lung Disease with Hyperpolarized 129Xe Gas-Exchange MRI
    Walkup, L.
    Willmering, M.
    Niedbalski, P.
    Cleveland, Z. I.
    Towe, C.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [10] Quantitative analysis of hyperpolarized 129Xe gas transfer MRI
    Wang, Ziyi
    Robertson, Scott Haile
    Wang, Jennifer
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Bier, Elianna A.
    Rajagopal, Sudarshan
    Huang, Yuh Chin
    O'Riordan, Thomas G.
    Rackley, Craig R.
    McAdams, H. Page
    Driehuys, Bastiaan