Modular 64x64 CdZnTe arrays with multiplexer readout for high-resolution nuclear medicine imaging

被引:2
|
作者
Woolfenden, JM [1 ]
Barber, HB [1 ]
Barrett, HH [1 ]
Dereniak, EL [1 ]
Eskin, JD [1 ]
Marks, DG [1 ]
Matherson, KJ [1 ]
Young, ET [1 ]
Augustine, FL [1 ]
机构
[1] Univ Arizona, Dept Radiol, Tucson, AZ 85724 USA
关键词
D O I
10.1557/PROC-487-239
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We are developing modular arrays of CdZnTe radiation detectors for high-resolution nuclear medicine imaging. Each detector is delineated into a 64x64 array of pixels; the pixel pitch is 380 mu m. Each pixel is connected to a corresponding pad on a multiplexer readout circuit. The imaging system is controlled by a personal computer. We obtained images of standard nuclear medicine phantoms in which the spatial resolution of approximately 1.5 mm was limited by the collimator that was used. Significant improvements in spatial resolution should be possible with different collimator designs. These results are promising for high-resolution nuclear medicine imaging.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 36 条
  • [1] Modular 64x64 CdZnTe arrays with multiplexer readout for high-resolution nuclear medicine imaging
    Woolfenden, JM
    Barber, HB
    Barrett, HH
    Dereniak, EL
    Eskin, JD
    Marks, DG
    Matherson, KJ
    Young, ET
    Augustine, FL
    INFRARED APPLICATIONS OF SEMICONDUCTORS II, 1998, 484 : 267 - 271
  • [2] Development of modular 64x64 CdZnTe imaging arrays with multiplexer readout.
    Woolfenden, JM
    Barber, HB
    Barrett, HH
    Dereniak, ES
    Eskin, JD
    Marks, DG
    Matherson, KJ
    Young, ET
    Augustine, FL
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 536 - 536
  • [3] Development of a 64x64 CdZnTe array and associated readout integrated circuit for use in nuclear medicine
    Barber, HB
    Barrett, HH
    Augustine, FL
    Hamilton, WJ
    Apotovsky, BA
    Dereniak, EL
    Doty, FP
    Eskin, JD
    Garcia, JP
    Marks, DG
    Matherson, KJ
    Woolfenden, JM
    Young, ET
    JOURNAL OF ELECTRONIC MATERIALS, 1997, 26 (06) : 765 - 772
  • [4] Progress in the development of large-area modular 64 x 64 CdZnTe imaging arrays for nuclear medicine
    Matherson, KJ
    Barber, HB
    Barrett, HH
    Eskin, JD
    Dereniak, EL
    Marks, DG
    Woolfenden, JM
    Young, ET
    Augustine, FL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 354 - 358
  • [5] Progress in the development of large-area modular 64 x 64 CdZnTe imaging arrays for nuclear medicine
    Matherson, KJ
    Barber, HB
    Barrett, HH
    Eskin, JD
    Dereniak, EL
    Marks, DG
    Woolfenden, JM
    Young, ET
    Augustine, FL
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 276 - 280
  • [6] Progress in the development of large-area modular 64 × 64 CdZnTe imaging arrays for nuclear medicine
    Matherson, K.J.
    Barber, H.B.
    Barrett, H.H.
    Eskin, J.D.
    Dereniak, E.L.
    Marks, D.G.
    Woolfenden, J.M.
    Young, E.T.
    Augustine, F.L.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 354 - 358
  • [7] Evaluation of a 48x48 CdZnTe array with multiplexer readout for high-resolution imaging.
    Woolfenden, JM
    Barber, HB
    Marks, DG
    Barrett, HH
    Dereniak, ES
    Eskin, JD
    Matherson, KJ
    Young, ET
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 202 - 202
  • [8] Development of a 64 × 64 CdZnTe array and associated readout integrated circuit for use in nuclear medicine
    H. B. Barber
    H. H. Barrett
    F. L. Augustine
    W. J. Hamilton
    B. A. Apotovsky
    E. L. Dereniak
    F. P. Doty
    J. D. Eskin
    J. P. Garcia
    D. G. Marks
    K. J. Matherson
    J. M. Woolfenden
    E. T. Young
    Journal of Electronic Materials, 1997, 26 : 765 - 772
  • [9] Progress in developing focal-plane-multiplexer readout for large CdZnTe arrays for nuclear medicine applications
    Barber, HB
    Marks, DG
    Apotovsky, BA
    Augustine, FL
    Barrett, HH
    Butler, JF
    Dereniak, EL
    Doty, FP
    Eskin, JD
    Hamilton, WJ
    Matherson, KJ
    Venzon, JE
    Woolfenden, JM
    Young, ET
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 262 - 265
  • [10] High-resolution imaging using a 48x48 Ge array with multiplexer readout
    Barber, HB
    Augustine, FL
    Barrett, HH
    Dereniak, EL
    Eskin, JD
    Marks, DG
    Matherson, KJ
    Venzon, JE
    Woolfenden, JM
    Young, ET
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 113 - 117