Enhancing trace acrylamide analysis by bromine derivatization coupled with direct-immersion solid-phase microextraction in drinking water

被引:1
|
作者
Li, Mian [1 ,2 ]
Lin, Yi-Li [3 ]
Zhang, Tian-Yang [1 ,4 ]
Xu, Bin [1 ,4 ]
Zhang, Min-Sheng [1 ]
Chu, Wen-Hai [1 ]
Tang, Yu-Lin [1 ]
机构
[1] Tongji Univ, Inst Disinfect By Prod Control Water Treatment, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resource Reuse, Shanghai, Peoples R China
[2] Guiyang Univ, Coll Biol & Environm Engn, Guiyang, Peoples R China
[3] Natl Kaohsiung First Univ Sci & Technol, Dept Safety Hlth & Environm Engn, Kaohsiung, Taiwan
[4] Shanghai Inst Pollut Control & Ecol Secur, Shanghai, Peoples R China
关键词
Acrylamide; bromine derivatization; direct-immersion solid-phase microextraction; gas chromatography coupled to mass spectrum; drinking water; GAS-CHROMATOGRAPHY; GC-MS; POTATO PRODUCTS; LC-MS/MS; FOOD; TRIHALOMETHANES;
D O I
10.1080/09593330.2020.1713905
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Acrylamide is a neurotoxic and genotoxic compound. It is abundant in drinking water because of the usage of polyacrylamide. Its high polarity and small molecular weight characteristics make it difficult to be extracted and analysed. In this study, a novel method was optimized for the determination of trace acrylamide in drinking water. The optimized method, uses bromine derivatization, can avoid false analysis of co-extractives and precursors effectively by transferring acrylamide to 2-bromopropenamide. The 2-bromopropenamide was extracted from water samples using DI-SPME and further analysed by GC-MS. This optimized method uses CAR/PDMS coating SPME fibre to extract at 55 degrees C for 45 min after the addition of 12 g Na2SO4, and then desorbs the extractions in GC injector at 260 degrees C for 3 min. The detection limit was 0.05 mu g/L with linearity ranging from 0.5 to 500 mu g/L. The repeatability and reproducibility relative standard deviation were 7.30% and 8.50%, respectively. The spiking recovery of tap water samples ranged from 100% to 106%. These results confirmed that this novel method was more precise and accurate than the previously reported SPME methods that used to analyse trace acrylamide in drinking water. The concentrations of acrylamide in the collected samples from clarification and filtration units were 0.80 and 0.71 g/L respectively.
引用
收藏
页码:2768 / 2775
页数:8
相关论文
共 50 条
  • [1] Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings
    Lopez-Darias, Jessica
    Pino, Veronica
    Anderson, Jared L.
    Graham, Christa M.
    Afonso, Ana M.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) : 1236 - 1243
  • [2] Determination of aldehydes in drinking water using pentafluorobenzylhydroxylamine derivatization and solid-phase microextraction
    Cancho, B
    Ventura, F
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 2002, 943 (01) : 1 - 13
  • [3] Comparison of the Conventional and Electroenhanced Direct-Immersion Solid-Phase Microextraction for Sampling of Nicotine in Biological Fluids of the Human Body
    Abdolhosseini, Sana
    Ghiasvand, Ali Reza
    Heidari, Nahid
    MOLECULES, 2018, 23 (05):
  • [4] Trace Analysis of Phenols and Chlorophenols in Water by in Situ Derivatization Headspace Solid-Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry
    Yu Yi-Jun
    Liu Hong-Ling
    Dai Xuan-Li
    Cai Huan-Xing
    Li Chun-Yu
    Yu Hong-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (09) : 1243 - 1248
  • [5] Analysis of aldehydes in water by solid-phase microextraction with on-fiber derivatization
    Tsai, SW
    Chang, CM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) : 143 - 150
  • [6] Capturing Plant Metabolome with Direct-Immersion in Vivo Solid Phase Microextraction of Plant Tissues
    Risticevic, Sanja
    Souza-Silva, Erica A.
    DeEll, Jennifer R.
    Cochran, Jack
    Pawliszyn, Janusz
    ANALYTICAL CHEMISTRY, 2016, 88 (02) : 1266 - 1274
  • [7] Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
    María Cordero-Vaca
    María J. Trujillo-Rodríguez
    Cheng Zhang
    Verónica Pino
    Jared L. Anderson
    Ana M. Afonso
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4615 - 4627
  • [8] Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
    Cordero-Vaca, Maria
    Trujillo-Rodriguez, Maria J.
    Zhang, Cheng
    Pino, Veronica
    Anderson, Jared L.
    Afonso, Ana M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (16) : 4615 - 4627
  • [9] Direct-immersion solid-phase microextraction coupled to fast gas chromatography mass spectrometry as a purification step for polycyclic aromatic hydrocarbons determination in olive oil
    Purcaro, Giorgia
    Picardo, Massimo
    Barp, Laura
    Moret, Sabrina
    Conte, Lanfranco S.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1307 : 166 - 171
  • [10] SOLID-PHASE MICROEXTRACTION FOR THE DIRECT ANALYSIS OF WATER - THEORY AND PRACTICE
    ARTHUR, CL
    POTTER, DW
    BUCHHOLZ, KD
    MOTLAGH, S
    PAWLISZYN, J
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1992, 10 (09): : 656 - &