Development of solid-phase chemiluminescence immunoassays for digoxin comparing flow injection and sequential injection techniques

被引:16
|
作者
Dreveny, D
Michalowski, J
Seidl, R
Gübitz, G
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Chem, A-8010 Graz, Austria
[2] Bialystok Univ, Inst Inorgan & Analyt Chem, PL-15443 Bialystok, Poland
关键词
D O I
10.1039/a804182b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a competitive solid-phase immunoassay for digoxin making use of the acridinium chemiluminescence system is described. Two different instrumental approaches are compared. One is based on a continuous flow system using a peristaltic flow injection analysis pump; the other uses a new sequential injection technique. Ln both systems a flow cell, consisting of transparent PTFE tubing packed with immobilized antibodies, acts as an immunoreactor. The entire assay, including both the immunoreaction and the chemiluminescence reaction, takes place in this immunoreactor cell. Compared with the flow injection technique, the sequential injection mode showed higher precision, ranging from 2.16 to 5.5% RSD depending on concentration. The total assay time, including regeneration, is less than 8 min with the sequential injection technique. The detection limit for both techniques is in the low femtomole range.
引用
收藏
页码:2271 / 2276
页数:6
相关论文
共 50 条
  • [1] Determination of Folic Acid by Solid-Phase Extraction and Flow Injection Chemiluminescence
    Zhao, Shi-Hao
    Zhang, Ping-Ping
    Zhao, Shi-Bin
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (10) : 7557 - 7562
  • [2] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (03) : 167 - 174
  • [3] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (02) : 141 - 148
  • [4] Development of enantio selective chemiluminescence flow- and sequential-injection immunoassays for α-amino acids
    Silvaieh, H
    Schmid, MG
    Hofstetter, O
    Schurig, V
    Gübitz, G
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 53 (1-3): : 1 - 14
  • [5] Determination of Sarafloxacin in Eggs by Flow Injection Chemiluminescence Combined with Solid-Phase Extraction
    Liu, Yue-Ying
    Zhao, Shi-Hao
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (18) : 10267 - 10269
  • [6] Rapid determination of gold in geological samples using flow injection solid-phase chemiluminescence
    Li, Jun-Feng
    Bai, Li-Fei
    Wang, Ying-Hua
    Wang, Hong-Yan
    ANALYTICAL SCIENCES, 2006, 22 (06) : 841 - 844
  • [7] Rapid Determination of Gold in Geological Samples Using Flow Injection Solid-Phase Chemiluminescence
    Jun-Feng Li
    Li-Fei Bai
    Ying-Hua Wang
    Hong-Yan Wang
    Analytical Sciences, 2006, 22 : 841 - 844
  • [8] Flow injection analysis of ultratrace orthophosphate in seawater with solid-phase enrichment and luminol chemiluminescence detection
    Liang, Ying
    Yuan, Dongxing
    Li, Quanlong
    Lin, Qingmei
    ANALYTICA CHIMICA ACTA, 2006, 571 (02) : 184 - 190
  • [9] Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
    Mervartova, Katerina
    Polasek, Miroslav
    Calatayud, Jose Martinez
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (03) : 367 - 381
  • [10] SOLID-PHASE REACTORS IN FLOW-INJECTION ANALYSIS
    DECASTRO, MDL
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (04) : 149 - 155