Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode

被引:62
|
作者
Bai, Jing [1 ]
Ndamanisha, Jean Chrysostome [1 ]
Liu, Lin [1 ]
Yang, Li [1 ]
Guo, Liping [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Peoples R China
基金
中国国家自然科学基金;
关键词
Ordered mesoporous carbon; Riboflavin; Vitamin B-2; Cyclic voltammetry; ADSORPTIVE STRIPPING VOLTAMMETRY; GLASSY-CARBON; SELECTIVE DETERMINATION; NANOPOROUS CARBON; VITAMERS; GLUCOSE; ACID; HPLC;
D O I
10.1007/s10008-010-1065-1
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The potential application of ordered mesoporous carbon (OMC)-modified glassy carbon electrode (OMC/GCE) in electrochemistry as a novel electrode material was investigated. X-ray diffraction, transmission electron micrographs, and cyclic voltammetry were used to characterize the structure and electrochemical behaviors of this material. Compared to GC electrode, the peak currents of potassium ferricyanide (K-3[Fe(CN)(6)]) increase and the peak potential separation (Delta E (p)) decreases at the OMC/GC electrode. These phenomena suggest that OMC-modified GC electrode possesses larger electrode area and faster electron transfer rate, as compared with bare GC electrode. Furthermore, riboflavin was detected using OMC/GC electrode in aqueous solutions. The results showed that, under an optimum condition (pH 7.0), the OMC/GC electrode exhibited excellent response performance to riboflavin in the concentration range of 4.0 x 10(-7) to 1.0 x 10(-6) M with a high sensitivity of 769 A mu A mM(-1). The detection limit was down to around 2 x 10(-8) M. With good stability and reproducibility, the present OMC/GC electrode was applied in the determination of vitamin B-2 content in vitamin tablets, and satisfactory results were obtained.
引用
收藏
页码:2251 / 2256
页数:6
相关论文
共 50 条
  • [1] Voltammetric detection of riboflavin based on ordered mesoporous carbon modified electrode
    Jing Bai
    Jean Chrysostome Ndamanisha
    Lin Liu
    Li Yang
    Liping Guo
    Journal of Solid State Electrochemistry, 2010, 14 : 2251 - 2256
  • [2] Simultaneous voltammetric determination of nitrophenol isomers at ordered mesoporous carbon modified electrode
    Zhang, Tingting
    Lang, Qiaolin
    Yang, Dapeng
    Li, Liang
    Zeng, Lingxing
    Zheng, Cheng
    Li, Tie
    Wei, Mingdeng
    Liu, Aihua
    ELECTROCHIMICA ACTA, 2013, 106 : 127 - 134
  • [3] Nonenzymatic glucose detection at ordered mesoporous carbon modified electrode
    Ndamanisha, Jean Chrysostome
    Guo, Liping
    BIOELECTROCHEMISTRY, 2009, 77 (01) : 60 - 63
  • [4] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Kurt Kalcher
    Microchimica Acta, 2016, 183 : 1619 - 1624
  • [5] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Mehmeti, Eda
    Stankovic, Dalibor M.
    Chaiyo, Sudkate
    Svorc, L'ubomir
    Kalcher, Kurt
    MICROCHIMICA ACTA, 2016, 183 (05) : 1619 - 1624
  • [6] Glassy carbon electrode modified with an ordered mesoporous carbon/Ag nanoparticle nanocomposite for the selective detection of iodate
    Heidari, Hassan
    Habibi, Biuck
    Vaigan, Fatemeh Bonyadi
    ANALYTICAL METHODS, 2016, 8 (22) : 4406 - 4412
  • [7] Electrochemical detection of natural estrogens using a graphene/ordered mesoporous carbon modified carbon paste electrode
    Zhu, Yanqiong
    Liu, Xiangjian
    Jia, Jianbo
    ANALYTICAL METHODS, 2015, 7 (20) : 8626 - 8631
  • [8] A Sensitive Voltammetric Sensor for Amaranth Based on Ordered Mesoporous Carbon
    Ju Jian
    Guo Li-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 681 - 686
  • [9] A Flow Injection Amperometric Sensor for Nitrate Detection Based on Cu Foam/Ordered Mesoporous Carbon Modified Glassy Carbon Electrode
    Junlapak, Nuttakorn
    Numnuam, Apon
    Nontipichet, Natha
    Kangkamano, Tawatchai
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Khumngern, Suntisak
    CHEMNANOMAT, 2024, 10 (06)
  • [10] Electrochemical determination of morphine at ordered mesoporous carbon modified glassy carbon electrode
    Li, Fei
    Song, Jixia
    Shan, Changsheng
    Gao, Dongmei
    Xu, Xiaoyu
    Niu, Li
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (06): : 1408 - 1413