Radiation hardness of PantherPix hybrid pixel detector

被引:0
|
作者
Dudas, D. [1 ,2 ]
Kafka, V. [1 ]
Marcisovsky, M. [1 ]
Neue, G. [1 ]
Marcisovska, M. [1 ]
Prusa, P. [1 ]
Koniarova, I. [3 ]
Semmler, M. [2 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Brehova 7, Prague 11519, Czech Republic
[2] UJP PRAHA As, Nad Kaminkou 1345, Prague 15600, Czech Republic
[3] Natl Radiat Protect Inst, Bartoskova 1450-28, Prague 14000, Czech Republic
关键词
Radiation damage to electronic components; Instrumentation for gamma-electron therapy; Radiation damage to detector materials (solid state); DAMAGE;
D O I
10.1088/1748-0221/16/12/P12007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Hybrid pixel detectors (HPD) are nowadays well known and widely used in fundamental research, e.g. in high energy physics experiments. Over the last decade, segmented semiconductor detectors have also found use in medicine. The total doses received by medical radiation detectors often reach a significant level (up to several hundreds of kGy per decade), especially in applications such as transmission portal in-vivo dosimetry. Such doses might affect detector properties. Therefore, it is necessary to evaluate their performance after absorbing a significant radiation dose. PantherPix is a novel 2D hybrid pixel detector which is designed specifically for use in radiation therapy. As was concluded in earlier studies, it is suitable for radiotherapy quality assurance (QA) and portal dosimetry. In this paper, the PantherPix radiation hardness is investigated using a Co-60 source. The dependence on dose of the full depletion voltage, leakage current, detector power consumption and detector response are provided. The PantherPix radiation tolerance has been shown to be adequate for common cumulative doses delivered to radiation detectors in radiotherapy over several decades and its performance has been verified for doses up to 3000 kGy.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] PantherPix hybrid pixel γ-ray detector for radio-therapeutic applications
    Neue, G.
    Benka, T.
    Havranek, M.
    Hejtmanek, M.
    Janoska, Z.
    Kafka, V.
    Korchak, O.
    Lednicky, D.
    Marcisovska, M.
    Marcisovsky, M.
    Popule, J.
    Smarhak, J.
    Svihra, P.
    Tomasek, L.
    Vrba, V.
    Koncek, O.
    Semmler, M.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [2] The use of Pantherpix pixel detector in radiotherapy QA
    Dudas, Denis
    Semmler, Milan
    Prusa, Petr
    Neue, Gordon
    Koniarova, Irena
    Peterkova, Katerina
    Gallus, Petr
    Koncek, Ondrej
    Vrba, Vaclav
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 332 - 340
  • [3] Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science
    Jungmann-Smith, J. H.
    Bergamaschi, A.
    Brueckner, M.
    Cartier, S.
    Dinapoli, R.
    Greiffenberg, D.
    Jaggi, A.
    Maliakal, D.
    Mayilyan, D.
    Medjoubi, K.
    Mezza, D.
    Mozzanica, A.
    Ramilli, M.
    Ruder, Ch.
    Schaedler, L.
    Schmitt, B.
    Shi, X.
    Tinti, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [4] Radiation-hard hybrid superconducting pixel detector
    Esposito, A
    Palmieri, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 198 - 200
  • [5] Investigation of hybrid pixel detector arrays by synchrotron-radiation imaging
    Helfen, L.
    Myagotin, A.
    Pernot, P.
    DiMichiel, M.
    Mikulik, P.
    Berthold, A.
    Baumbach, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 163 - 166
  • [6] Radiation-hard optical hybrid board for the ATLAS pixel detector
    Rahimi, A
    Arms, KE
    Gan, KK
    Johnson, M
    Kagan, H
    Rush, C
    Smith, S
    Ter-Antonian, R
    Zoeller, MM
    Ciliox, A
    Holder, M
    Nderitu, S
    Ziolkowski, M
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (16): : 3805 - 3807
  • [7] Hybrid superconducting pixel detector
    Palmieri, V
    Esposito, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 396 (1-2): : 277 - 280
  • [8] Double-Redundant Design Methodology to Improve Radiation Hardness in Pixel Detector Readout ICs
    Frontini, Luca
    Liberali, Valentino
    Shojaii, Seyed Ruhollah
    Stabile, Alberto
    2015 IEEE CONFERENCE ON ELECTRONICS, CIRCUITS, AND SYSTEMS (ICECS), 2015, : 396 - 399
  • [9] Radiation Damage Effects on Epitaxial Silicon Devices for the PANDA Hybrid Pixel Detector
    Braghieri, A.
    Busso, L.
    Calvo, D.
    De Remigis, P.
    Jaeckel, R.
    Montagna, P.
    Morra, O.
    Wheadon, R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1814 - +
  • [10] Radiation hardness studies of silicon pixel detectors
    Lari, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (01): : 93 - 97