Phytochemical Characterization for Quality Control of Phyllostachys pubescens Leaves Using High-Performance Liquid Chromatography Coupled with Diode Array Detector and Tandem Mass Detector

被引:4
|
作者
Seo, Chang-Seob [1 ]
Song, Kwang-Hoon [2 ]
机构
[1] Korea Inst Oriental Med, KM Sci Res Div, Yuseong Daero 1672, Daejeon 34054, South Korea
[2] Korea Inst Oriental Med, KM Convergence Res Div, Yuseong Daero 1672, Daejeon 34054, South Korea
来源
PLANTS-BASEL | 2022年 / 11卷 / 01期
关键词
quality assessment; bamboo; LC-MS; MS; method validation; BAMBOO LEAVES; QUANTITATIVE-ANALYSIS; CHLOROGENIC ACIDS; CONSTITUENTS; EXTRACTS; ANTIOXIDANT; FLAVONOIDS; WATER;
D O I
10.3390/plants11010050
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Phyllostachys pubescens leaves are cultivated in a number of Asian countries and have been used for antipyretic and diuretic effects since ancient times, especially in Korea. The purpose of this study was to develop and validate of analytical method for quality control of P. pubescens leaves using high-performance liquid chromatography with diode array detector (HPLC-DAD) and liquid chromatography with tandem mass spectrometry (LC-MS/MS) detection. HPLC-DAD analysis was conducted with a Gemini C-18 column, and distilled water-acetonitrile (both with 0.1% (v/v) formic acid) mobile-phase system. For the LC-MS/MS analysis, all markers were separated with a Waters ACQUITY UPLC BEH C-18 column and gradient flow system of distilled water containing 0.1% (v/v) formic acid and 5 mM ammonium formate-acetonitrile. In both method, major components were detected at 2.13-11.63 mg/g (HPLC-DAD) and 0.12-19.20 mg/g (LC-MS/MS). These methods were validated with respect to linearity (coefficient of determination >0.99), recovery (95.22-118.81%), accuracy (90.52-116.96), and precision (<4.0%), and were successfully applied for the quantitative analysis of P. pubescens leaves.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Identification of phenolic compounds in Myricaria bracteata leaves by high-performance liquid chromatography with a diode array detector and liquid chromatography with tandem mass spectrometry
    Chernonosov, Alexander A.
    Karpova, Evgeniya A.
    Lyakh, Elena M.
    REVISTA BRASILEIRA DE FARMACOGNOSIA-BRAZILIAN JOURNAL OF PHARMACOGNOSY, 2017, 27 (05): : 576 - 579
  • [2] Identification of phenolic compounds in Myricaria bracteata leaves by high-performance liquid chromatography with a diode array detector and liquid chromatography with tandem mass spectrometry
    Alexander A. Chernonosov
    Evgeniya A. Karpova
    Elena M. Lyakh
    Revista Brasileira de Farmacognosia, 2017, 27 : 576 - 579
  • [3] Quality evaluation of cortex moutan by high performance liquid chromatography coupled with diode array detector and electrospary ionization tandem mass spectrometry
    He, Qing
    Ge, Zhi-Wei
    Song, Yue
    Cheng, Yi-Yu
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2006, 54 (09) : 1271 - 1275
  • [4] Quality evaluation of Hpericum japomicum by using high-performance liquid chromatography coupled with photodiode array detector and electrospray ionization tandem mass spectrometry
    Gao, Wei-Na
    Luo, Jian-Guang
    Kong, Ling-Yi
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (09) : 1022 - 1030
  • [5] Quality and antioxidant activity detection of Crataegus leaves using on-line high-performance liquid chromatography with diode array detector coupled to chemiluminescence detection
    Ding, Xiao-Ping
    Wang, Xin-Tang
    Chen, Lin-Lin
    Qi, Jin
    Xu, Tian
    Yu, Bo-Yang
    FOOD CHEMISTRY, 2010, 120 (03) : 929 - 933
  • [6] Determination of Pesticides in Sunflower Seeds by High-Performance Liquid Chromatography Coupled with a Diode Array Detector
    Tuzimski, Tomasz
    Rejczak, Tomasz
    JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (04) : 1012 - 1020
  • [7] Simultaneous determination of eight components in Radix Tinosporae by high-performance liquid chromatography coupled with diode array detector and electrospray tandem mass spectrometry
    Shi, Qirong
    Yan, Shikai
    Liang, Mingjin
    Yang, Yun
    Wang, Yan
    Zhang, Weidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) : 994 - 999
  • [8] Determination of Fluorescent Whitening Agents in Cosmetics and Liquid Detergent by High-Performance Liquid Chromatography with Diode Array Detector in Tandem with Fluorescence Detector
    Gu, Yu-Xiang
    Yang, Jin-Qin
    Pan, Si-Yi
    Wang, Lei
    Zhou, Ze-Lin
    JOURNAL OF COSMETIC SCIENCE, 2018, 69 (04) : 279 - 291
  • [9] QUALITY CONTROL OF CRATAEGUS PINNATIFIDA BASED ON HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH DIODE ARRAY DETECTOR
    Weon, Jin Bae
    Lee, Bohyoung
    Yun, Bo-Ra
    Lee, Jiwoo
    Ma, Choong Je
    PHARMACEUTICAL BIOLOGY, 2012, 50 (11) : 1362 - 1363
  • [10] An ultrafiltration high-performance liquid chromatography coupled with diode array detector and mass spectrometry approach for screening and characterising tyrosinase inhibitors from mulberry leaves
    Yang, Zhenzhong
    Zhang, Yufeng
    Sun, Lijuan
    Wang, Yi
    Gao, Xiumei
    Cheng, Yiyu
    ANALYTICA CHIMICA ACTA, 2012, 719 : 87 - 95