Validation and implementation of the PowerPlex® 16 BIO system STR multiplex for forensic casework

被引:0
|
作者
Greenspoon, SA
Ban, JD
Pablo, L
Crouse, CA
Kist, FG
Tomsey, CS
Glessner, AL
Mihalacki, LR
Long, TM
Heidebrecht, BJ
Braunstein, CA
Freeman, DA
Soberalski, C
Bruesehoff, N
Amin, AS
Douglas, EK
Schumm, JW
机构
[1] Virginia Div Forens Sci, Richmond, VA 23219 USA
[2] Palm Beach Cty Sheriffs Off, W Palm Beach, FL USA
[3] Penn State Police DNA Lab, Greensburg, PA USA
[4] Penn State Police DNA Lab, Bethlehem, PA USA
[5] Bode Technol Grp, Springfield, MD USA
关键词
forensic science; PowerPlex (R) 16 BIO System; STR; gel electrophoresis; validation study;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The PowerPlex(R) 16 BIO multiplex short tandem repeat (STR) system contains the 13 CODIS loci (FGA, TPOX, D8S1179, vWA, D18S51, D21S11, TH01, D3S1358, CSF1PO, D16S539, D7S820, D13S317, and D5S818), plus two pentanucleotide repeat loci (Penta D and Penta E) and the sex-identifying locus, Amelogenin. The PowerPlex(R) 16 BIO System is optimized for use with the Hitachi FMBIO(R) gel imaging systems. A consortium of seven independent laboratories collaborated to perform the studies defined by the FBI standards for performing a developmental validation, including the evaluation of sample concordance, percent stutter determination, nonprobative casework, precision, sensitivity, mixture determination, effect of substrates, the impact of environmental insults, and species specificity. All samples tested for concordance were consistent except for one sample from the Virginia Division of Forensic Science database that displayed discordance at D13S317, a locus whose primer sequence was altered. Stutter values were comparable to those of other STR multiplex systems, the precision was comparable to other multiplexes analyzed by gel electrophoresis, the DNA profiles were unchanged by the substrate upon which the blood samples were placed, and the nonprobative casework samples re-typed for the PowerPlex(R) 16 BIO System were consistent with previous typing results. When greater than 0.125 ng of DNA was placed into the PowerPlex(R) 16 BIO System amplification reaction, a full profile was generated by all laboratories. The mixture study results were comparable to those reported for other multiplex systems, the environmental study demonstrated a loss of larger molecular weight loci when samples were incubated at elevated temperatures for a prolonged period of time, and the only notable cross species hybridization was observed with primate DNA samples. This extensive validation work performed demonstrates that the PowerPlex(R) 16 BIO System provides STR data of a quality comparable with other PowerPlex(R) STR multiplex kits as well as other widely used STR multiplexes and is thus suitable for evidentiary casework analysis as well as database sample profiling.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [1] VALIDATION OF THE PROMEGA POWERPLEX (R) 16 STR MULTIPLEX SYSTEM FOR FORENSIC CASEWORK
    McGrory, J.
    Sloots, J.
    Hunt, D.
    Ford, R.
    Frappier, R.
    Newman, J.
    CANADIAN SOCIETY OF FORENSIC SCIENCE JOURNAL, 2005, 38 (02) : 85 - 99
  • [2] Forensic validation of the PowerPlex® ESI 16 STR Multiplex and comparison of performance with AmpFlSTR® SGM Plus®
    Valerie C. Tucker
    Amanda J. Kirkham
    Andrew J. Hopwood
    International Journal of Legal Medicine, 2012, 126 : 345 - 356
  • [3] Validation and comparative study of the AmpFlSTR® Identifiler™ and the PowerPlex™ 16 STR mulitiplex systems for forensic casework using capillary electrophoresis
    Metwalley, SH
    Al-Awadhi, A
    Abdulla, SM
    Kassem, LA
    Hadad, N
    FORENSIC SCIENCE INTERNATIONAL, 2003, 136 : 54 - 55
  • [4] Developmental validation of the PowerPlex® 16 HS System: An improved 16-locus fluorescent STR multiplex
    Ensenberger, Martin G.
    Thompson, Jonelle
    Hill, Becky
    Homick, Kristen
    Kearney, Veronica
    Mayntz-Press, Kathleen A.
    Mazur, Paul
    McGuckian, Amy
    Myers, Jelena
    Raley, Kelli
    Raley, Stewart G.
    Rothove, Robin
    Wilson, Jonathan
    Wieczorek, Doug
    Fulmer, Patricia M.
    Storts, Douglas R.
    Krenke, Benjamin E.
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2010, 4 (04) : 257 - 264
  • [5] Developmental validation of the PowerPlex® Y23 System: A single multiplex Y-STR analysis system for casework and database samples
    Thompson, Jonelle M.
    Ewing, Margaret M.
    Frank, William E.
    Pogemiller, Jill J.
    Nolde, Craig A.
    Koehler, D. Jody
    Shaffer, Alyssandra M.
    Rabbach, Dawn R.
    Fulmer, Patricia M.
    Sprecher, Cynthia J.
    Storts, Douglas R.
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2013, 7 (02) : 240 - 250
  • [6] Casework experiences with a multiplex STR system.
    Greenhalgh, MJ
    ADVANCES IN FORENSIC HAEMOGENETICS, 6, 1996, 6 : 249 - 251
  • [7] A Bayesian approach to validating STR multiplex databases for use in forensic casework
    L. A. Foreman
    A. F. M. Smith
    I. W. Evett
    International Journal of Legal Medicine, 1997, 110 : 244 - 250
  • [8] A Bayesian approach to validating STR multiplex databases for use in forensic casework
    Foreman, LA
    Smith, AFM
    Evett, IW
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1997, 110 (05) : 244 - 250
  • [9] Allele frequencies for STR loci of the PowerPlex™16 multiplex system in five endogamous populations of India
    Kashyap, VK
    Sarkar, N
    Trivedi, R
    FORENSIC SCIENCE INTERNATIONAL, 2002, 126 (02) : 178 - 186
  • [10] Validation and casework application of a Y chromosome specific STR multiplex
    Prinz, M
    Ishii, A
    Coleman, A
    Baum, HJ
    Shaler, RC
    FORENSIC SCIENCE INTERNATIONAL, 2001, 120 (03) : 177 - 188