Impact of UVC-sustained recirculating air filtration on airborne bacteria and dust in a pig facility

被引:25
|
作者
Eisenloeffel, Lisa [1 ]
Reutter, Tobias [2 ]
Horn, Matthias [3 ]
Schlegel, Simon [4 ]
Truyen, Uwe [1 ]
Speck, Stephanie [1 ]
机构
[1] Univ Leipzig, Inst Anim Hyg & Vet Publ Hlth, Leipzig, Germany
[2] REVENTA GmbH, Horstmar, Germany
[3] Univ Leipzig, Inst Med Informat Stat & Epidemiol IMISE, Leipzig, Germany
[4] SterilAir AG, Weinfelden, Switzerland
来源
PLOS ONE | 2019年 / 14卷 / 11期
关键词
ULTRAVIOLET GERMICIDAL IRRADIATION; RESPIRATORY SYNDROME VIRUS; PORCINE PARVOVIRUS; RELATIVE-HUMIDITY; MYCOPLASMA-HYOPNEUMONIAE; SERRATIA-MARCESCENS; INACTIVATION; VENTILATION; MICROORGANISMS; TRANSMISSION;
D O I
10.1371/journal.pone.0225047
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
High amounts of aerial pollutants like dust and microorganisms can pose serious health hazards to animals and humans. The aim of the current study therefore was, to assess the efficiency of UVC irradiation combined to air filtration in reducing airborne microorganisms at laboratory scale. In a second part, a UVC-combined recirculating air filtration module (UVC module) was implemented in a small animal facility in order to assess its improvement of air quality with regard to airborne bacteria and dust. Tests at laboratory scale were performed using aerosols of Staphylococcus (S.) aureus, Actinobacillus pleuropneumoniae, porcine parvovirus (PPV) and porcine reproductive and respiratory syndrome virus. We varied relative humidity (RH) to evaluate its effect on UVC irradiation efficiency. In addition, viability of pathogens inside the filter material was determined over up to six months. UVC-combined air filtration resulted in a more than 99% reduction of viral and bacterial particles. RH had no influence on UVC efficiency. Viability in the filter matter varied depending on the pathogen used and RH with S. aureus and PPV being most resistant. In our small pig facility consisting of two separated barns, weekly air measurements were conducted over a period of 13 weeks (10 piglets) and 16 weeks (11 piglets), respectively. Airborne bacterial numbers were significantly lower in the barn equipped with the UVC module compared to the reference barn. On average a reduction to 37% of reference values could be achieved for bacteria, whereas the amount of total dust was reduced to a much lesser extent (i.e. to 78% of reference values). Measures taken in front of and behind the UVC module revealed a reduction of 99.4% for airborne bacteria and 95.0% for total dust. To conclude, recirculating air filtration combined to UVC provided efficient reduction of pathogens at laboratory and experimental scale. The implementation of such devices might improve the overall environmental quality in animal facilities.
引用
收藏
页数:18
相关论文
共 17 条
  • [1] Recirculating air filtration significantly reduces exposure to airborne nanoparticles
    Pui, David Y. H.
    Qi, Chaolong
    Stanley, Nick
    Oberdorster, Gunter
    Maynard, Andrew
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2008, 116 (07) : 863 - 866
  • [2] AIRPLANE AIR-QUALITY - AIRBORNE BACTERIA AND DUST ALLERGENS
    MUILENBERG, M
    BURGE, H
    DAHLSTROM, C
    DUMYAHN, T
    SPENGLER, J
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 95 (01) : 325 - 325
  • [3] Impact of different supply air and recirculating air filtration systems on stable climate, animal health, and performance of fattening pigs in a commercial pig farm
    Wenke, Cindy
    Pospiech, Janina
    Reutter, Tobias
    Altmann, Bettina
    Troyen, Uwe
    Speck, Stephanie
    PLOS ONE, 2018, 13 (03):
  • [4] Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room
    Anthony, T. Renee
    Altmaier, Ralph
    Jones, Samuel
    Gassman, Rich
    Park, Jae Hong
    Peters, Thomas M.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2015, 12 (09) : 635 - 646
  • [5] EFFECT OF INTERNAL AIR FILTRATION ON THE PERFORMANCE OF BROILERS AND THE AERIAL CONCENTRATIONS OF DUST AND BACTERIA
    CARPENTER, GA
    SMITH, WK
    MACLAREN, APC
    SPACKMAN, D
    BRITISH POULTRY SCIENCE, 1986, 27 (03) : 471 - 480
  • [6] A study on the filtration efficiency of an air filter over airborne bacteria and fungi vs elapsed time
    Dept. of Architectural Hygiene and Housing, National Institute of Public Health, 2-3-6 Minami Wako-shi, Saitama 351-0197, Japan
    不详
    HB - Heal. Build.: Creating Heal. Indoor Environ. People, Proc., (479-482):
  • [7] The Airborne Dust Reservoir effect of Tarim Basin and its impact on air quality
    Yin, Xiao-Yan
    Fan, Jin
    Zhang, Meng
    Wu, Xin-Ni
    Zhang, Xiao-Jiao
    Chen, Qiang
    Wang, Shi-Gong
    Zhongguo Huanjing Kexue/China Environmental Science, 2020, 40 (02): : 546 - 553
  • [8] Comparative measurements of airborne bacteria by using filtration (MD8) and impingement (AGI 30) in a composting facility
    Albrecht, A
    Witzenberger, R
    Bernzen, U
    Kämpfer, P
    Jäkel, U
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2005, 65 (09): : 358 - 362
  • [9] A study of local electrostatic filtration and main pre-filtration on airborne and surface dust levels in air-conditioned office premises
    Croxford, B
    Tham, KW
    Young, A
    Oreszczyn, T
    Wyon, D
    INDOOR AIR, 2000, 10 (03) : 170 - 177
  • [10] Detection of Airborne Bacteria in a Duck Production Facility with Two Different Personal Air Sampling Devices for an Exposure Assessment
    Martin, Elena
    Dziurowitz, Nico
    Jaeckel, Udo
    Schaefer, Jenny
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2015, 12 (02) : 77 - 86