A comparison between the combustion of natural gas and partially reformed natural gas in an atmospheric lean premixed turbine-type combustor

被引:10
|
作者
Delattin, Frank [1 ]
Rabhiou, Abderahman [1 ]
Bram, Svend [1 ]
De Ruyck, Jacques [1 ]
Orbay, Raik [2 ]
Klingmann, Jens [2 ]
Konnov, Alexander A. [3 ]
机构
[1] Vrije Univ Brussels, Dept Mech Engn, B-1050 Brussels, Belgium
[2] Lund Univ, Dept Energy Sci, Lund, Sweden
[3] Tech Univ Eindhoven, Dept Mech Engn, NL-5600 MB Eindhoven, Netherlands
关键词
combustion; flame; hydrogen; reforming;
D O I
10.1080/00102200802125552
中图分类号
O414.1 [热力学];
学科分类号
摘要
A small-scale combustor was set up to analyze the combustion of natural gas and two mixtures of partially reformed natural gas. The partially reformed mixtures can be formed using biomass to feed the endothermic reforming reactions. Before combusting these mixtures in a gas turbine, experimental work was done on a primary zone combustion chamber to examine the combustor behavior when switching from natural gas to the wet and dry hydrogen-rich mixtures. Temperature profiles, flame location and ignition limits have been investigated for a variety of stoichiometries and several air temperatures. Possible problems concerning blow-off, flashback, increased pollutant products and excessive liner wall temperatures were analyzed. It was concluded that the switch in operation from natural gas to these wet and/or dry partially reformed natural gas mixtures lowers the blow-off limits while maintaining similar liner wall temperature profiles. Furthermore, no significant changes in pollutant production were observed. Flame area, shape and position display considerable differences in combustion regime for the three tested fuel types.
引用
收藏
页码:1478 / 1501
页数:24
相关论文
共 50 条
  • [1] Combustion instability mechanism of a lean premixed gas turbine combustor
    Seonghyeon Seo
    KSME International Journal, 2003, 17 (6): : 906 - 913
  • [2] Combustion instability mechanism of a lean premixed gas turbine combustor
    Se, S
    KSME INTERNATIONAL JOURNAL, 2003, 17 (06): : 906 - 913
  • [3] COMPARISON OF EQUIVALENCE RATIO FLUCTUATIONS IN A LEAN PREMIXED COMBUSTOR FOR KEROSENE AND NATURAL GAS
    Vogel, Manuel
    Kaufmann, Jan
    Voelkl, Vinzenz
    Hirsch, Christoph
    Sattelmayer, Thomas
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 3A, 2023,
  • [4] Lean-limit combustion instabilities of a lean premixed prevaporized gas turbine combustor
    Dhanuka, Sulabh K.
    Temme, Jacob E.
    Driscoll, James F.
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2011, 33 : 2961 - 2966
  • [5] Dynamic properties of combustion instability in a lean premixed gas-turbine combustor
    Gotoda, Hiroshi
    Nikimoto, Hiroyuki
    Miyano, Takaya
    Tachibana, Shigeru
    CHAOS, 2011, 21 (01)
  • [6] Active control of combustion oscillations in a lean premixed gas-turbine combustor
    Aeroengine Technology Centre, Japan Aerospace Exploration Agency, 7-44-1 Jindaiji-Higashi, Chofu, Tokyo 182-8522, Japan
    不详
    不详
    不详
    不详
    Int J Veh Des, 2007, 1-4 (306-321):
  • [7] Effects of Unmixedness on Combustion Instabilities in a Lean-Premixed Gas Turbine Combustor
    Seonghyeon Seo
    Seong-Young Lee
    Flow, Turbulence and Combustion, 2010, 85 : 95 - 112
  • [8] Active control of combustion oscillations in a lean premixed gas-turbine combustor
    Tachibana, Shigeru
    Zimmer, Laurent
    Kurosawa, Yoji
    Suzuki, Kazuo
    Sato, Hiroyuki
    Hayashi, A. Koichi
    Nishidome, Chiaki
    Kajiwara, Itsuro
    INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 2007, 43 (1-4) : 306 - 321
  • [9] Effects of Unmixedness on Combustion Instabilities in a Lean-Premixed Gas Turbine Combustor
    Seo, Seonghyeon
    Lee, Seong-Young
    FLOW TURBULENCE AND COMBUSTION, 2010, 85 (01) : 95 - 112
  • [10] Effect of partially premixed and hydrogen addition on natural gas direct-injection lean combustion
    State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
    Int J Hydrogen Energy, 1600, 22 (9239-9247):