Determination of free calcium at a carbon paste electrode adsorptive stripping voltammetric method

被引:0
|
作者
Liu, N [1 ]
Song, JF [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Xian 710069, Peoples R China
关键词
calcium; carbon paste electrode; adsorptive stripping voltammetry; single sweep voltammetry;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A cathodic adsorptive stripping voltammetric method for the determination of free calcium is described, based on the reduction of calcium-alizarin red S (ARS) complex at a carbon paste electrode (CPE). In 1.5 x 10(-2) mol/L potassium hydroxide solution containing 2.0 x 10(-5) mol/L ARS, the complex adsorbed on the CPE surface yields a reduction wave with peak potential 0.89 V. When accumulation potential is -0.1 V, accumulation time is 90 s and scan rate is 100 mV/s, the second-order derivative cathodic stripping peak current of the adsorbed complex is proportional to free calcium concentration in the range of 3.0 X 10(-8) similar to 2.0 X 10(-6) mol/L by single sweep voltammetry. The detection limit is 9.4 x 10(-9) mol/L. With rinsing the CPE in 0.2 mol/L HCl solution for 2 min, it shows good reproducibility. The proposed method has been applied to the rapid determination of free calcium in serum, milk and tap water.
引用
收藏
页码:1261 / 1264
页数:4
相关论文
共 20 条
  • [1] AN JR, 1985, ACTA CHIM SINICA, V43, P524
  • [2] ANDREY B, 2000, ANAL CHIM ACTA, V408, P57
  • [3] [陈辉 Chen Hui], 2003, [光谱实验室, Chinese Journal of Spectroscopy laboratory], V20, P376
  • [4] Determination of calcium, iron and zinc in milk powder by reaction cell inductively coupled plasma mass spectrometry
    Chen, KL
    Jiang, SJ
    [J]. ANALYTICA CHIMICA ACTA, 2002, 470 (02) : 223 - 228
  • [5] Dong SY, 2003, CHINESE J ANAL CHEM, V31, P604
  • [6] Jo GB, 1999, ELECTROANAL, V11, P885, DOI 10.1002/(SICI)1521-4109(199908)11:12<885::AID-ELAN885>3.0.CO
  • [7] 2-Y
  • [8] SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993
    KALCHER, K
    KAUFFMANN, JM
    WANG, J
    SVANCARA, I
    VYTRAS, K
    NEUHOLD, C
    YANG, Z
    [J]. ELECTROANALYSIS, 1995, 7 (01) : 5 - 22
  • [9] Maruszak W, 1999, CHEM ANAL-WARSAW, V44, P437
  • [10] Evidence for various calcium sites in human hair shaft revealed by sub-micrometer X-ray fluorescence
    Mérigoux, C
    Briki, F
    Sarrot-Reynauld, F
    Salomé, M
    Fayard, B
    Susini, J
    Doucet, J
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2003, 1619 (01): : 53 - 58