Experimental simulation of liquid entrainment in ADS-4 depressurization line in AP1000

被引:9
|
作者
Xiang, Y. [1 ]
Wu, Y. W. [1 ]
Sun, D. C. [1 ,3 ]
Tian, W. X. [1 ]
Zhang, P. [2 ]
Qiu, S. Z. [1 ]
Su, G. H. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, 28 Xianming West Rd, Xian 710049, Peoples R China
[2] State Nucl Power Technol R&D Ctr, Beijing 100190, Peoples R China
[3] Nucl Power Inst China, Chengdu, Sichuan, Peoples R China
基金
对外科技合作项目(国际科技项目);
关键词
Simulation experiment; ADS-4; Upper plenum; Entrainment; Depressurization;
D O I
10.1016/j.pnucene.2016.05.006
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The fourth stage Automatic Depressurization System is an important passive safety feature in Westinghouse AP1000 which enables controlled depressurization of reactor coolant system in small break LOCA. However, large amount of coolant can be carried to the containment via the ADS-4 branch entrainment and the upper plenum entrainment during the depressurization process, which poses great threats to core uncovering and melting. The automatic Depressurization and Entrainment TEst Loop (ADETEL) modeled after AP1000 with a scaling ratio of 1:5.6 was constructed to investigate the entrainment and depressurization behavior after the actuation of ADS-4 valves. The entrainment and depressurization features were investigated under different initial pressure, mixture liquid level in the pressure vessel and heating power. The entrainment deposition effect of the reactor internals was also investigated. The test data reveals that large amount of water are entrained through the ADS-4 branch line within a short period of time. The liquid entrainment rate and the reduced rate of the mixture liquid level in the pressure vessel increase with the initial system pressure. It is notable that the core uncovery was experienced when the initial pressure was set to 0.5 MPa in current experimental conditions. The reactor internals have little effect on the entrained mass and the mixture liquid levels in the pressure vessel. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 50 条
  • [1] Scaling analysis of AP1000 ADS-4 entrainment and depressurization
    Sun, D. C.
    Tian, W. X.
    Qiu, S. Z.
    Su, G. H.
    Zhang, P.
    Liu, J. C.
    Ma, Y. Y.
    PROGRESS IN NUCLEAR ENERGY, 2014, 74 : 71 - 78
  • [2] Experimental research of liquid entrainment through ADS-4 in AP1000
    Meng, Zhaoming
    Dong, Bo
    Wang, Laishun
    Fu, Xiaoliang
    Tian, Wenxi
    Yang, Yanhua
    Su, Guanghui
    ANNALS OF NUCLEAR ENERGY, 2014, 72 : 428 - 437
  • [3] RESEARCH OF LIQUID ENTRAINMENT THROUGH ADS-4 IN AP1000
    Meng, Zhaoming
    Fu Xiao-liang
    Ding, Lei
    Tian, Wenxi
    Dong, Bo
    Su, Guanghui
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2A, 2014,
  • [4] Experimental and simulative investigation of ADS-4 depressurization process in AP1000
    Xiang, Y.
    Wu, Y. W.
    Qiu, S. Z.
    Tian, W. X.
    Su, G. H.
    PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 3, 2016,
  • [5] Experimental investigation of liquid entrainment in AP1000 ADS-4 branch line with air-water
    Sun, D. C.
    Xiang, Y.
    Zhang, J.
    Tian, W. X.
    Zhang, P.
    Qiu, S. Z.
    Su, G. H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 57 : 317 - 323
  • [6] Theoretical investigation of liquid entrainment through ADS-4 in AP1000
    Ding, Lei
    Fu, Xiao-Liang
    Meng, Zhao-Ming
    Liu, Li-Fang
    Tian, Wen-Xi
    Yang, Yan-Hua
    Su, Guang-Hui
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (05): : 801 - 806
  • [7] CFD study on onset of liquid entrainment through ADS-4 branch line in AP1000
    Khan, Irfan
    Wang, Mingjun
    Zhang, Yapei
    Tian, Wenxi
    Su, Guanghui
    Qiu, Suizheng
    NUCLEAR ENGINEERING AND DESIGN, 2021, 380
  • [8] Experimental and theoretical investigation of liquid entrainment through small-scaled ADS-4 in AP1000
    Meng, Zhaoming
    Fu, Xiaoliang
    Ding, Lei
    Dong, Bo
    Tian, Wenxi
    Yang, Yanhua
    Su, Guanghui
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 57 : 177 - 187
  • [9] Model application research for liquid entrainment through ADS-4 pipe in AP1000
    Meng, Zhaoming
    Ding, Lei
    Qiu, Zicheng
    Sun, Zhongning
    Yan, Changqi
    Qiu, Suizheng
    Su, Guanghui
    Tian, Wenxi
    ANNALS OF NUCLEAR ENERGY, 2017, 110 : 1043 - 1051
  • [10] Experimental investigation of liquid entrainment in ADS-4 depressurization line with steam-water
    Sun, D. C.
    Qiu, S. Z.
    Xiang, Y.
    Zhang, J.
    Tian, W. X.
    Zhang, P.
    Su, G. H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 61 : 221 - 229