Long-term performance evaluation of positron emission tomography: analysis and proposal of a maintenance protocol for long-term utilization

被引:9
|
作者
Watanuki, Shoichi [1 ]
Tashiro, Manabu [1 ]
Miyake, Masayasu [1 ]
Ishikawa, Yoichi [2 ]
Itoh, Masatoshi [1 ]
Yanai, Kazuhiko [1 ]
Sakemi, Yasuhiro [3 ]
Fukuda, Hiroshi [1 ,4 ]
Ishii, Keizo [1 ,5 ]
机构
[1] Tohoku Univ, Ctr Cyclotron & Radioisotope, Div Cyclotron Nucl Med, Aoba Ku, Sendai, Miyagi 9808578, Japan
[2] Tohoku Univ, Ctr Cyclotron & Radioisotope, Div Radiopharmaceut Chem, Aoba Ku, Sendai, Miyagi 9808578, Japan
[3] Tohoku Univ, Ctr Cyclotron & Radioisotope, Div Instrumentat, Aoba Ku, Sendai, Miyagi 9808578, Japan
[4] Tohoku Univ, Inst Dev Aging & Canc, Sendai, Miyagi 9808578, Japan
[5] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Aoba Ku, Sendai, Miyagi 9808578, Japan
关键词
Positron emission tomography (PET); Quality control; Cross calibration; PET/CT SCANNER; STABILITY;
D O I
10.1007/s12149-010-0381-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET) scanners require periodic monitoring in order to maintain scanner performance. The aim of the present study was to examine the deterioration of PET scanner performance caused by aging. We retrospectively examined PET scanner performance alterations in terms of sensitivity, spatial resolution, false coincidences due to scatter and random coincidences based on 13 years of follow-up data, including data when the PET scanner underwent an overhaul at the 10th year after installation. Sensitivity and scatter fraction were calculated by using cross calibration factor (CCF) measurement data, which are collected routinely. Efficacy of the examining the sensitivity and scatter was confirmed by NEMA measurements. Trans-axial resolution was measured as full width at half-maximum (FWHM) and full width at tenth-maximum (FWTM) at 0-20 cm offset from the field of view (FOV) center at the time of installation, 8 years after installation, and immediately after the overhaul. Random coincidence rate fraction was measured in a wide range of count rates before and after the overhaul. The results indicated that the total reduction of sensitivity during the first 10 years was 41% of the initial value in terms of NEMA measurement, and that the annual reduction of sensitivity progressed at a rate of 4.7% per year in terms of CCF measurement data. The changes in sensitivity can be calculated using CCF measurement data. Regarding the spatial resolution, mean FWHM and FWTM values were increased by 1.7 and 3.6%, respectively, in 8 years after installation. The relative scatter fraction was significantly increased compared with that before the overhaul. The random fraction decreased by 10-15% after the overhaul within a certain range of random count rates (1-120 kcps). In the case of our scanner, the parameter that displayed the largest change was the sensitivity, and this change was thought to be caused by the reduction of photomultiplier tube (PMT) gain, although the changes in PMT gain can cause various types of performance deterioration, as investigated in this study. We observed that the sensitivity of our PET scanner generally deteriorated due to aging. Sensitivity monitoring using CCF measurements can be an easy and useful method for monitoring and maintaining the performance of PET scanners against aging. Since the data were obtained from a single scanner, the authors would encourage the initiation of a follow-up study involving various scanners.
引用
收藏
页码:461 / 468
页数:8
相关论文
共 50 条
  • [1] Long-term performance evaluation of positron emission tomography: analysis and proposal of a maintenance protocol for long-term utilization
    Shoichi Watanuki
    Manabu Tashiro
    Masayasu Miyake
    Yoichi Ishikawa
    Masatoshi Itoh
    Kazuhiko Yanai
    Yasuhiro Sakemi
    Hiroshi Fukuda
    Keizo Ishii
    Annals of Nuclear Medicine, 2010, 24 : 461 - 468
  • [2] Long-term positron emission tomography evaluation of slowly progressive gliomas
    Mineura, K
    Sasajima, T
    Kowada, M
    Ogawa, T
    Hatazawa, J
    Uemura, K
    EUROPEAN JOURNAL OF CANCER, 1996, 32A (07) : 1257 - 1260
  • [3] LONG-TERM PERFORMANCE OF A MULTIPLANAR POSITRON EMISSION TOMOGRAPH
    KEARFOTT, KJ
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (08) : 1378 - 1385
  • [4] Positron emission tomography in evaluation of dementia - Regional brain metabolism and long-term outcome
    Silverman, DHS
    Small, GW
    Chang, CY
    Lu, CS
    de Aburto, MAK
    Chen, W
    Czernin, J
    Rapoport, SI
    Pietrini, P
    Alexander, GE
    Schapiro, MB
    Jagust, WJ
    Hoffman, JM
    Welsh-Bohmer, KA
    Alavi, A
    Clark, CM
    Salmon, E
    de Leon, MJ
    Mielke, R
    Cummings, JL
    Kowell, AP
    Gambhir, SS
    Hoh, CK
    Phelps, ME
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (17): : 2120 - 2127
  • [5] SHORT-TERM AND LONG-TERM VERBAL MEMORY - A POSITRON EMISSION TOMOGRAPHY STUDY
    ANDREASEN, NC
    OLEARY, DS
    ARNDT, S
    CIZADLO, T
    HURTIG, R
    REZAI, K
    WATKINS, GL
    PONTO, LLB
    HICHWA, RD
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (11) : 5111 - 5115
  • [6] LONG-TERM PROGNOSIS OF POSTSTROKE APHASIA STUDIED WITH POSITRON EMISSION TOMOGRAPHY
    KARBE, H
    KESSLER, J
    HERHOLZ, K
    FINK, GR
    HEISS, WD
    ARCHIVES OF NEUROLOGY, 1995, 52 (02) : 186 - 190
  • [7] Long-term monitoring of transplanted islets using positron emission tomography
    Lu, Yuxin
    Dang, Hoa
    Middleton, Blake
    Campbell-Thompson, Martha
    Atkinson, Mark A.
    Gambhir, Sanjiv Sam
    Tian, Jide
    Kaufman, Daniel L.
    MOLECULAR THERAPY, 2006, 14 (06) : 851 - 856
  • [8] Positron-emission tomography imaging of long-term shape recognition challenges
    Rosier, A
    Cornette, L
    Dupont, P
    Bormans, G
    Michiels, J
    Mortelmans, L
    Orban, GA
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (14) : 7627 - 7632
  • [9] Evaluation of long-term performance of VIPs
    Johansson, Par
    Adl-Zarrabi, Bijan
    Berge, Axel
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 388 - 393
  • [10] Evaluation of an oxygen protocol in long-term care
    Christman, Sherrie L.
    Volsko, Teresa A.
    RESPIRATORY CARE, 2006, 51 (12) : 1424 - 1431