A systematic review of variability and reliability of manual and automated blood pressure readings

被引:53
|
作者
Skirton, Heather [1 ]
Chamberlain, Wendy [2 ]
Lawson, Caroline [3 ]
Ryan, Helen
Young, Emma [4 ]
机构
[1] Univ Plymouth, Fac Hlth, Taunton TA1 5YD, Somerset, England
[2] Musgrove Pk Hosp, Taunton & Somerset Fdn Trust, Taunton, Somerset, England
[3] Yeovil Dist Hosp NHS Fdn Trust, Queensway Treatment Ctr, Higher Kingston, England
[4] Yeovil Dist Hosp NHS Fdn Trust, Yeovil, Somerset, England
关键词
blood pressure; nursing; observations; systematic review; vital signs; HYPERTENSION; SPHYGMOMANOMETERS; SOCIETY; DEVICE; POPULATION; VALIDATION; ACCURACY; ABC;
D O I
10.1111/j.1365-2702.2010.03528.x
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Aims and objectives. To compare the accuracy and appropriateness of auscultatory (manual) and oscillometric (automated) devices for measuring blood pressure in clinical settings. Background. Accurate measurement of blood pressure is integral to early recognition of deterioration in the condition of a patient. Despite recommendations regarding the use of auscultatory devices in situations where treatment decisions are made dependent on blood readings, the use of automated machines is becoming common practice. Design. Systematic review. Methods. A search of the Medline, CINAHLPlus and The Cochrane Library databases was undertaken for papers published in English between January 1997-May 2009. Sixteen studies were identified that fulfilled the inclusion criteria. After quality assessment, all were included in the review. Results are presented in tabular and narrative form. Results. In 10 of the studies reviewed, the authors came to the conclusion that oscillometric devices were less accurate than auscultatory devices. However, in most cases the oscillometric device appears sufficiently accurate for clinical use, the exceptions being use with hypertensive patients, patients with arrhythmia and after trauma. Only two studies assessed the comparative accuracy of aneroid devices, and these indicated that they were more accurate than oscillometric devices, but the differences were not clinically important. Conclusions. There are situations where the substitution of oscillometric for auscultatory devices could have particularly serious repercussions for the patient, such as when the patient is either hypertensive or hypotensive. However, further research is required on the use of aneroid sphygmomanometers as a replacement for mercury devices. Relevance to clinical practice. Practitioners should be made aware of the need to use auscultatory devices in specific circumstances, such as in management of hypertension, after the patient has experienced trauma or where there is significant potential for deterioration in the patient's condition.
引用
收藏
页码:602 / 614
页数:13
相关论文
共 50 条
  • [1] Concordance and variability of blood pressure measurement between automated and manual readings in subjects receiving phenylephrine
    Terra, SG
    Blum, RA
    Wei, GC
    Digenio, AG
    Rajman, I
    Kazierad, DJ
    JOURNAL OF CLINICAL PHARMACOLOGY, 2003, 43 (09): : 1027 - 1027
  • [2] VARIABILITY OF BLOOD PRESSURE READINGS
    JONAS, AD
    NEW YORK STATE JOURNAL OF MEDICINE, 1950, 50 (10) : 1249 - 1251
  • [3] RELIABILITY OF BLOOD-PRESSURE READINGS IN INFANCY
    OSULLIVAN, MJ
    KEARNEY, PJ
    CROWLEY, MJ
    IRISH MEDICAL JOURNAL, 1993, 86 (05) : 171 - 171
  • [4] Sleep and blood pressure variability: A systematic literature review
    Kim, Yeonsu
    Mattos, Meghan Kathleen
    Esquivel, Jill Howie
    Davis, Eric M.
    Logan, Jeongok
    HEART & LUNG, 2024, 68 : 323 - 336
  • [5] Are Automated Blood Pressure Apparatus Reliable? Automated Versus Manual Measurement of Blood Pressure
    Srinivasan, K. Madhan
    Kumar, K. Senthil
    Saraswathi, I.
    Raaju, A. Lokeshwar
    Rao, B. Vishwanatha
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (08) : CC9 - CC12
  • [6] Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension A Systematic Review and Meta-analysis
    Roerecke, Michael
    Kaczorowski, Janusz
    Myers, Martin G.
    JAMA INTERNAL MEDICINE, 2019, 179 (03) : 351 - 362
  • [7] VARIABILITY AND SIMILARITY OF MANUAL OFFICE AND AUTOMATED BLOOD PRESSURES
    BOTTINI, PB
    CARR, AA
    PRISANT, LM
    RHOADES, RB
    JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 32 (07): : 614 - 619
  • [8] ACCURACY OF AUTOMATED BLOOD PRESSURE MONITORS IN CHILDREN: A SYSTEMATIC REVIEW
    Kollias, A.
    Boubouchairopoulou, N.
    Ntineri, A.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2017, 35 : E173 - E174
  • [9] Correspondence: Are Automated Blood Pressure Apparatus Reliable? Automated Versus Manual Measurement of Blood Pressure
    Mondal, Himel
    Mondal, Shaikat
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (12)
  • [10] Blood pressure variability assessed by home measurements: a systematic review
    George S Stergiou
    Angeliki Ntineri
    Anastasios Kollias
    Takayoshi Ohkubo
    Yutaka Imai
    Gianfranco Parati
    Hypertension Research, 2014, 37 : 565 - 572