Microbiological evaluation of a range of disinfectant products to control mixed-species biofilm contamination in a laboratory model of a dental unit water system

被引:105
|
作者
Walker, JT [1 ]
Bradshaw, DJ
Fulford, MR
Marsh, PD
机构
[1] Hlth Protect Agcy, Salisbury SP4 0JG, Wilts, England
[2] Lees Dent Inst, Leeds, W Yorkshire, England
关键词
D O I
10.1128/AEM.69.6.3327-3332.2003
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Dental unit water system (DUWS) tubing harbors complex multispecies biofilms that are responsible for high microbial levels at the distal outlet. The aim of this study was to use an established biofilm laboratory model to simulate biofouling of DUWS to evaluate practical, cost-effective, and evidence-based methods of microbial decontamination. Reproducible biofilms were developed in the model over 14 days; decontamination was assessed using total viable counts (TVC) and microscopic-image analysis techniques to view the inner surface of tubing. Flushing did not reduce the biofilm coverage or TVC. Combizyme and ozone did not completely eliminate the viable bacteria (70 and 65% reduction in biofilm TVC, respectively), nor did they remove the biofilm (45 and 57% reduction in biofilm coverage, respectively). Chlorhexidine and Bio2000 (active agent: ethanol and chlorhexidine), Tegodor and Gigasept Rapid (aldehyde based), and Grotanol (hydroxide based) completely eliminated the TVC but did not completely remove biofilm (31, 53 33, 34, and 64.9% reduction of biofilm coverage, respectively). Other products including Grotanol Flussig (phenol based), Betadine (povidone-iodine based), Alpron (chlorite based), and the hydroxide-containing products Sporklenz, Sterilex Ultra, Dialox, Sterilox, Sanosil, Oxigenal, and Grotanat Bohrerbad resulted in a 100% reduction in the biofilm TVC and a >95% reduction in biofilm coverage. The study demonstrated that while many disinfectants achieve a sufficient reduction in TVC they may not necessarily remove unwanted biofilm from the tubing surfaces as tested in this laboratory-controlled biofilm model.
引用
收藏
页码:3327 / 3332
页数:6
相关论文
共 9 条
  • [1] Control of planktonic and biofilm contamination in a laboratory dental unit water system.
    Walker, JT
    Bradshaw, DJ
    Fulford, MR
    Martin, MV
    Marsh, PD
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A445 - A445
  • [2] Effect of Mixed-Species Biofilm on Copper Surfaces in Cooling Water System
    Gungor, Nihal Dogruoz
    Cotuk, Aysin
    Ilhan-Sungur, Esra
    Cansever, Nurhan
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2015, 24 (02) : 848 - 858
  • [3] Effect of Mixed-Species Biofilm on Copper Surfaces in Cooling Water System
    Nihal Doğruöz Güngör
    Ayşın Çotuk
    Esra Ilhan-Sungur
    Nurhan Cansever
    Journal of Materials Engineering and Performance, 2015, 24 : 848 - 858
  • [4] Setup of an In Vitro Test System for Basic Studies on Biofilm Behavior of Mixed-Species Cultures with Dental and Periodontal Pathogens
    Standar, Kerstin
    Kreikemeyer, Bernd
    Redanz, Sylvio
    Muenter, Wanja L.
    Laue, Michael
    Podbielski, Andreas
    PLOS ONE, 2010, 5 (10):
  • [5] Evaluation of the simulator with automatic irrigation control system designed for countermeasures of internal contamination in dental unit water lines
    Okubo, Keisuke
    Ito, Takashi
    Okamoto, Kentaro
    Yamamoto, Ichiro
    Mizutani, Hajime
    Kawata, Yusuke
    Shiota, Yasuyoshi
    Ito, Masahiro
    Nakamura, Shin
    Tai, Masako
    Yamamoto, Tadashi
    Takashiba, Shogo
    HELIYON, 2020, 6 (06)
  • [6] Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro
    Pan, J.
    Li, Y. L.
    Liu, C. M.
    Tian, Y.
    Yu, S.
    Wang, K. L.
    Zhang, J.
    Fang, J.
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2017, 37 (04) : 1091 - 1103
  • [7] Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro
    J. Pan
    Y. L. Li
    C. M. Liu
    Y. Tian
    S. Yu
    K. L. Wang
    J. Zhang
    J. Fang
    Plasma Chemistry and Plasma Processing, 2017, 37 : 1091 - 1103
  • [8] Effective control of dental chair unit waterline biofilm and marked reduction of bacterial contamination of output water using two peroxide-based disinfectants
    Tuttlebee, CM
    O'Donnell, MJ
    Keane, CT
    Russell, RJ
    Sullivan, DJ
    Falkiner, F
    Coleman, DC
    JOURNAL OF HOSPITAL INFECTION, 2002, 52 (03) : 192 - 205
  • [9] A novel automated waterline cleaning system that facilitates effective and consistent control of microbial biofilm contamination of dental chair unit waterlines: A one-year study
    O'Donnell, M. J.
    Shore, A. C.
    Coleman, D. C.
    JOURNAL OF DENTISTRY, 2006, 34 (09) : 648 - 661