Water Defluoridation: Nanofiltration vs Membrane Distillation

被引:38
|
作者
Ayala, Lucia I. Moran [1 ]
Paquet, Marie [2 ]
Janowska, Katarzyna [2 ]
Jamard, Paul [2 ]
Jensen, Cejna A. Quist [2 ]
Bosio, Gabriela N. [1 ]
Martire, Daniel O. [1 ]
Fabbri, Debora [3 ]
Boffa, Vittorio [2 ]
机构
[1] Univ Nacl La Plata, CONICET, Inst Invest Fisicoquim Teor & Aplicada INIFTA, Diagonal 113 & Calle 64, RA-1900 La Plata, Buenos Aires, Argentina
[2] Aalborg Univ, Dept Chem & Biosci, Fredrik Bajers Vej 7H, DK-9220 Aalborg, Denmark
[3] Univ Torino, Dipartimento Chim, Via P Giuria 5, I-10125 Turin, Italy
关键词
REVERSE-OSMOSIS MEMBRANES; FLUORIDE REMOVAL; BRACKISH GROUNDWATER; DESALINATION; PERFORMANCE; RETENTION; SINGLE; CRYSTALLIZATION; OPTIMIZATION; TECHNOLOGY;
D O I
10.1021/acs.iecr.8b03620
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Nowadays, fluoride contamination of drinking water is a major problem for various countries, because high concentrations of fluoride pose a risk of dental and skeletal fluorosis. Over past years, membrane nanofiltration (NF) has been proposed as convenient defluoridation technology. However, NF cannot be applied, to water systems with high fluoride concentration, and the disposal of the membrane concentrate remains an issue. In this work, we compared a commercial polyester NF membrane and a polypropylene hollow fiber membrane distillation (MD) module for their ability to remove fluoride ions from water in the presence of hardness ions and organic fouling agents. The NF membrane can offer more than 10 times higher water productivity than MD, under realistic gradients of temperature and pressure, respectively. Despite that, after reaching a concentration factor of about 3, fouling and scaling caused the flux to drop to about 80% with respect to its initial value. Moreover, F- retention decreased from 90% to below 80%, thus providing a permeate of scarce quality. MD was operated in the direct-contact mode on a polypropylene hollow fiber membrane, which was charged with a hot feed flow (average T = 58 degrees C) on one side and a cooled (20 degrees C) permeate flow of distilled water on the other side. The concentration of fluoride ions in the permeate was always below the detection limit of our electrode (0.2 ppm), regardless of the fluoride concentration in the feed. Moreover, the MD module showed higher resistance to fouling and scaling than NF, and CaF2 crystals were recovered from the MD concentrate after cooling. These results suggest that the synergic combination of the two techniques might be beneficial for the purification of fluoride contaminated water systems: MD can be used to further concentrate the NF retentate, thus producing high-purity water and recovering CaF2 crystals.
引用
收藏
页码:14740 / 14748
页数:9
相关论文
共 50 条
  • [1] Defluoridation of water by nanofiltration
    Ben Nasr, A.
    Charcosset, C.
    Ben Amar, R.
    Walha, K.
    JOURNAL OF FLUORINE CHEMISTRY, 2013, 150 : 92 - 97
  • [2] Water defluoridation using nanofiltration vs. reverse osmosis: the first world unit, Thiadiaye (Senegal)
    Pontie, Maxime
    Dach, Hanane
    Lhassani, Abdekhaadi
    Diawara, Courfia Keba
    DESALINATION AND WATER TREATMENT, 2013, 51 (1-3) : 164 - 168
  • [3] 3D printed nanofiltration membrane technology for waste water distillation
    Khan, Sadaf Bashir
    Irfan, Syed
    Lam, Su Shiung
    Sun, Xiaohong
    Chen, Shenggui
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 49
  • [4] Contrasting mixed scaling patterns and mechanisms of nanofiltration and membrane distillation
    Zheng, Libing
    Wu, Qiyang
    Ulbricht, Mathias
    Zhong, Hui
    Duan, Ningxin
    Van der Bruggen, Bart
    Wei, Yuansong
    WATER RESEARCH, 2024, 258
  • [5] Comparison of membrane distillation and high-temperature nanofiltration processes for treatment of silica-saturated water
    Bush, John A.
    Vanneste, Johan
    Cath, Tzahi Y.
    JOURNAL OF MEMBRANE SCIENCE, 2019, 570 : 258 - 269
  • [6] Ceramic nanofiltration and membrane distillation hybrid membrane processes for the purification and recycling of boric acid from simulative radioactive waste water
    Chen, Xianfu
    Chen, Ting
    Li, Jian
    Qiu, Minghui
    Fu, Kaiyun
    Cui, Zhaoliang
    Fan, Yiqun
    Drioli, Enrico
    JOURNAL OF MEMBRANE SCIENCE, 2019, 579 : 294 - 301
  • [7] Water purification by membrane distillation
    Gryta, M
    Tomaszewska, M
    Morawski, AW
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (02): : 311 - 322
  • [8] Water purification by membrane distillation
    2001, Ars Polona (22):
  • [9] Treatment of surface water contaminated with ketoprofen: submerged photocatalytic membrane reactor vs. membrane distillation unit
    Mozia, Sylwia
    Rajakumaran, Revathy
    Szymanski, Kacper
    Grzechulska-Damszel, Joanna
    DESALINATION AND WATER TREATMENT, 2023, 316 : 493 - 504
  • [10] Rejection of Tetracycline and Oxytetracycline in Water by a Nanofiltration Membrane
    Li, Weiying
    Sun, Xiuli
    Wang, Qing
    Xu, Jingjing
    Lu, Junyu
    2ND INTERNATIONAL SYMPOSIUM ON AQUA SCIENCE, WATER RESOURCE AND LOW CARBON ENERGY, 2010, 1251 : 113 - +