Gas-Liquid Contactors' Aeration Capacities When Agitated by Rushton Turbines of Various Diameters

被引:2
|
作者
Kracik, Tomas [1 ]
Moucha, Tomas. [1 ]
Petricek, Radim [1 ,2 ]
机构
[1] Univ Chem & Technol, Dept Chem Engn, Prague 16628, Czech Republic
[2] Czech Acad Sci, Inst Hydrodynam, Prague 16612, Czech Republic
来源
ACS OMEGA | 2020年 / 5卷 / 10期
关键词
MASS-TRANSFER CORRELATIONS; OXYGEN-TRANSFER COEFFICIENT; DYNAMIC PRESSURE METHOD; POWER INPUT; HOLD-UP; DESIGN; VESSEL; RATES; K(L)A; COALESCENCE;
D O I
10.1021/acsomega.9b04005
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mass transfer processes are one of the most important operations in chemical, biochemical, and food industries worldwide. In the processes that are controlled by the gas-liquid mass transfer rate, the volumetric mass transfer coefficient k(L)a becomes a crucial quantity. The dataset was measured with the aim to create a correlation for k(L)a prediction in a non-coalescent batch under the wide range of experimental conditions. The dynamic pressure method, which was reported as physically correct in the past, was chosen to be the method for experimental determination of k(L)a. Our previous work targeted the k(L)a dependencies in viscous and coalescent batches resulting in correlations that are viable for the broad range of process conditions. We reported that the best-fit correlation is based on the hydrodynamic parameter circumferential velocity of impeller blades in the case of non-coalescent liquids in the vessel equipped by single or multiple impellers at a constant D/T ratio (diameter of the impeller to the inner diameter of the tank). Now, we focus on the influence of various impeller diameters on transport characteristics (mainly k(L)a) in a non-coalescent batch. The experiments are carried out in a multiple-impeller vessel equipped with Rushton turbines (of four diameters) and in both laboratory and pilot-plant scales. Various impeller frequencies and gas flow rates are used. We examine the suitability of the hydrodynamic description, which was reported in the past, to predict k(L)a also when the D/T ratio changes. We show that the correlation based on the energy dissipation rate better fits the experimental data and predicts k(L)a values more accurately in the case of varying D/T values. This correlation could be adopted in the design and scaleup of agitated devices operating with non-coalescent batches.
引用
收藏
页码:5072 / 5077
页数:6
相关论文
共 50 条
  • [1] Power consumption in gas-liquid contactors agitated by doubled-stage rushton turbines
    Markopoulos, J.
    Pantuflas, E.
    Chemical Engineering and Technology, 2001, 24 (11): : 1147 - 1150
  • [2] Power consumption in gas-liquid contactors agitated by double-stage rushton turbines
    Markopoulos, J
    Pantuflas, E
    CHEMICAL ENGINEERING & TECHNOLOGY, 2001, 24 (11) : 1147 - 1150
  • [3] Dispersion characteristics of gas-liquid contactors agitated by single and double-stage Rushton turbines
    Markopoulos, J
    Paras, SV
    Babalona, E
    CHEMICAL ENGINEERING & TECHNOLOGY, 2002, 25 (02) : 163 - 166
  • [4] Complete dispersion characteristics in gas-liquid contactors agitated by single- and double-stage Rushton turbines
    Babalona, E
    Paras, SV
    Markopoulos, J
    CHEMICAL ENGINEERING & TECHNOLOGY, 2005, 28 (02) : 137 - 139
  • [5] Regional mean bubble diameters and gas holdup in agitated gas-liquid contactors
    Markopoulos, Joannis
    Kadoglou, Efterpi
    Papaevangelou, Diogenes
    Zavitsanou, Andronike
    Chemical Engineering and Technology, 2000, 23 (04): : 337 - 339
  • [6] Regional mean bubble diameters and gas holdup in agitated gas-liquid contactors
    Markopoulos, J
    Kadoglou, E
    Papaevangelou, D
    Zavitsanou, A
    CHEMICAL ENGINEERING & TECHNOLOGY, 2000, 23 (04) : 337 - 339
  • [7] MIXING IN GAS-LIQUID CONTACTORS AGITATED BY MULTIPLE TURBINES IN THE FLOODING REGIME
    ALVES, SS
    VASCONCELOS, JMT
    CHEMICAL ENGINEERING SCIENCE, 1995, 50 (14) : 2355 - 2357
  • [8] Performance of agitated gas-liquid contactors
    Cooper, CM
    Fernstrom, GA
    Miller, SA
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1944, 36 : 504 - 509
  • [9] Gas hold-up in gas-liquid contactors agitated by pitched blade turbines
    Markopoulos, J
    Alexiou, S
    CHEMICAL ENGINEERING COMMUNICATIONS, 2001, 187 : 265 - 268
  • [10] Power consumption in agitated gas-liquid system in the conditions of the interaction of flows inducted by Rushton turbines
    Kamienski, J
    Niznik, J
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3C): : 585 - 590