Intraocular lens factors that may affect anterior capsule contraction

被引:44
|
作者
Hayashi, K
Hayashi, H
机构
[1] Hayashi Eye Hosp, Hakata Ku, Fukuoka 812, Japan
[2] Fukuoka Univ, Sch Med, Dept Ophthalmol, Fukuoka 81401, Japan
关键词
D O I
10.1016/j.ophtha.2004.11.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the various factors comprising intraocular lenses (IOLs) that may affect the degree of anterior capsule contraction after cataract surgery. Design: Randomized controlled clinical trials. Participants: Three hundred thirty-one patients scheduled for bilateral cataract surgery were studied to compare the degree of anterior capsule contraction in fellow eyes that received different IOLs with regard to the following factors: (1) optic material-acrylic optic versus silicone optic; (2) optic design-round-edge optic versus sharp-edge optic; (3) haptic material-polymethyl methacrylate (PMMA) loop versus polyvinylidene fluoride loop; and (4) haptic material and design-single-piece acrylic haptic versus 3-piece PMMA haptic. The 2 IOLs implanted in the fellow eyes of each patient had almost the same material and design, except for the specific factor being compared. Methods: All patients underwent phacoemulsification surgery with implantation of different IOLs in fellow eyes. Main Outcome Measures: The area of the anterior capsule opening was measured using the Scheimpflug videophotography system at 3 days or 1 week (baseline) and at 1, 3, and 6 months after surgery. The percent reduction in the anterior capsule opening area from baseline was determined at 1, 3, and 6 months after surgery. Results: The mean percent reduction of the anterior capsule opening area was significantly greater in eyes with a silicone optic IOL than in eyes with an acrylic optic IOL. However, no significant difference was observed in the percent reduction between round-edge and sharp-edge optic IOLs, between PMMA and polyvinylidene fluoride loop IOLs, and between single-piece acrylic and 3-piece PMMA haptic IOLs. Strong associations were found in the percentage between round-edge and sharp-edge optic IOLs, between PMMA and polyvinylidene fluoride loop IOLs, and between single-piece acrylic and 3-piece PMMA haptic IOLs, whereas there was a relatively weak association between silicone and acrylic optic IOLs. Conclusions: Among the IOL factors examined, optic material affects most significantly the degree of anterior capsule contraction, whereas optic design and haptic material and design are not strongly related to anterior capsule contraction.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 50 条
  • [1] Influence of intraocular lens implantation on anterior capsule contraction and posterior capsule opacification
    Aose, Masamoto
    Matsushima, Hiroyuki
    Mukai, Koichiro
    Katsuki, Yoko
    Gotoh, Norihito
    Senoo, Tadashi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12): : 2128 - 2133
  • [2] Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome
    Hayashi, H
    Hayashi, K
    Nakao, F
    Hayashi, F
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (12) : 1429 - 1432
  • [3] Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) : 1294 - 1297
  • [4] Inhibition of anterior capsule opacification and contraction by the elevated anterior rim of the intraocular lens optic
    Nagata, Mayumi
    Matsushima, Hiroyuki
    Mukai, Koichiro
    Senoo, Tadashi
    Nishi, Okihiro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2023, 67 (06) : 693 - 698
  • [5] Inhibition of anterior capsule opacification and contraction by the elevated anterior rim of the intraocular lens optic
    Mayumi Nagata
    Hiroyuki Matsushima
    Koichiro Mukai
    Tadashi Senoo
    Okihiro Nishi
    Japanese Journal of Ophthalmology, 2023, 67 : 693 - 698
  • [6] Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models
    Ioannis T. Tsinopoulos
    Konstantinos T. Tsaousis
    George D. Kymionis
    Chrysanthos Symeonidis
    Michael A. Grentzelos
    Vasilios F. Diakonis
    Maria Adaloglou
    Stavros A. Dimitrakos
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1155 - 1158
  • [7] Comparison of anterior capsule contraction between 5 foldable intraocular lens models
    Nagata, Mayumi
    Matsushima, Hiroyuki
    Mukai, Koichiro
    Terauchi, Wataru
    Gotoh, Norihito
    Matsui, Eichiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1495 - 1498
  • [8] Comparison of anterior capsule contraction between hydrophobic and hydrophilic intraocular lens models
    Tsinopoulos, Ioannis T.
    Tsaousis, Konstantinos T.
    Kymionis, George D.
    Symeonidis, Chrysanthos
    Grentzelos, Michael A.
    Diakonis, Vasilios F.
    Adaloglou, Maria
    Dimitrakos, Stavros A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (08) : 1155 - 1158
  • [9] Bimanual anterior segment revision surgery for anterior capsule contraction syndrome associated with anterior flexion of intraocular lens haptics
    Zinkernagel, M.
    Papazoglou, A.
    Patel, C. K.
    EYE, 2013, 27 (12) : 1388 - 1390
  • [10] Bimanual anterior segment revision surgery for anterior capsule contraction syndrome associated with anterior flexion of intraocular lens haptics
    M Zinkernagel
    A Papazoglou
    C K Patel
    Eye, 2013, 27 : 1388 - 1390