Coincidence-summing correction equations in gamma-ray spectrometry with p-type HPGe detectors

被引:45
|
作者
Tomarchio, E. [1 ]
Rizzo, S. [1 ]
机构
[1] Univ Palermo, Dipartimento Ingn Nucl, I-90128 Palermo, Italy
关键词
Coincidence-summing; Gamma-ray spectrometry; HPGe detectors;
D O I
10.1016/j.radphyschem.2010.09.014
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Equations to compute gamma-gamma and gamma-x(K) coincidence-summing corrections in gamma-ray spectrometry with p-type HPGe detectors are reported. For point sources only full-energy-peak and total efficiencies are needed. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 50 条
  • [1] Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors
    Rizzo, S.
    Tomarchio, E.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 555 - 560
  • [2] Uncertainties of calculated coincidence-summing correction factors in gamma-ray spectrometry
    Semkova, V
    Otuka, N.
    Plompen, A. J. M.
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [3] Virtual point detector: Application to coincidence-summing correction in gamma-ray spectrometry
    Rizzo, S.
    Tomarchio, E.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1448 - 1450
  • [4] Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry
    Lee, Jieun
    Kim, HyoJin
    Kye, Yong Uk
    Lee, Dong Yeon
    Kim, Jeung Kee
    Jo, Wol Soon
    Kang, Yeong-Rok
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (05) : 1754 - 1759
  • [5] COINCIDENCE-SUMMING CORRECTIONS IN GAMMA-RAY SPECTROMETRY FOR NORMALIZED GEOMETRIES
    MOREL, J
    CHAUVENET, B
    KADACHI, A
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08): : 1115 - 1122
  • [6] Monte Carlo calculations of coincidence-summing corrections for volume sources in gamma-ray spectrometry with Ge detectors
    García-Toraño, E
    Pozuelo, M
    Salvat, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 544 (03): : 577 - 583
  • [7] A national campaign for coincidence-summing correction in γ-ray spectrometry
    De Felice, P
    Angelini, P
    Fazio, A
    Capogni, M
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 117 - 123
  • [8] Fast procedures for coincidence-summing correction in γ-ray spectrometry
    De Felice, P
    Angelini, P
    Fazio, A
    Biagini, R
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 745 - 752
  • [9] Coincidence-summing in gamma-ray spectrometry by excitation of matrix X-rays
    Arnold, D
    Sima, O
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 725 - 732
  • [10] Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors
    Laborie, JM
    Le Petit, G
    Abt, D
    Girard, M
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (1-2) : 57 - 62