Experimental analysis for the determination of the convective heat transfer coefficient by measuring pressure drop directly during annular condensation flow of R134a in a vertical smooth tube

被引:14
|
作者
Dalkilic, A. S. [1 ]
Teke, I. [1 ]
Wongwises, S. [2 ]
机构
[1] Yildiz Tech Univ, Heat & Thermodynam Div, Dept Mech Engn, TR-34349 Istanbul, Turkey
[2] King Mongkuts Univ Technol Thonburi, Dept Mech Engn, Fluid Mech Thermal Engn & Multiphase Flow Res Lab, Bangkok 10140, Thailand
关键词
Condensation; Two-phase pressure drop; Heat transfer coefficient; Vertical downward flow; R134a; VOID FRACTION MODELS; HIGH-MASS FLUX; 2-PHASE FRICTION FACTOR; DOWNWARD FLOW; PIPES;
D O I
10.1016/j.ijheatmasstransfer.2010.06.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigated the direct relationship between the measured condensation pressure drop and convective heat transfer coefficient of R134a flowing downward inside a vertical smooth copper tube having an inner diameter of 8.1 mm and a length of 500 mm during annular flow. R134a and water were used as working fluids on the tube side and annular side of a double tube heat exchanger, respectively. Condensation experiments were performed at mass fluxes of 260, 300, 340, 400, 456 and 515 kg m(-2) s(-1) in the high mass flux region of R134a. The condensing temperatures were around 40 and 50 degrees C; the heat fluxes were between 10.16 and 66.61 kW m(-2). Paliwoda's analysis, which focused mainly on the determination of the two-phase flow factor and two-phase length of evaporators and condensers, was adapted to the in-tube condensation phenomena in the test section to determine the condensation heat transfer coefficient, heat flux, two-phase length and pressure drop experimentally by means of a large number of data points obtained under various experimental conditions. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1008 / 1014
页数:7
相关论文