Experimental Optimization of Flow Distributors for Pressure-Driven Separations and Reactions in Flat-Rectangular Microchannels

被引:18
|
作者
Vangelooven, Joris [1 ]
Schlautman, Stefan [2 ]
Detobel, Frederik [1 ]
Gardeniers, Han [2 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, Transport Modelling & Analyt Separat Sci Grp, Brussels, Belgium
[2] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
关键词
LIQUID-CHROMATOGRAPHY COLUMNS; FRACTIONATION CHANNELS; DISPERSION; REDUCTION; PHASE;
D O I
10.1021/ac101304p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the results of an experimental study established to optimize the design of microfabricated flow distributors for use in pressure-driven separations and reactions in flat-rectangular channels. For this purpose, the performance of a wide variety of possible flow distributor designs etched in glass/silicon wafers was compared, using CCD camera detection to study the shape and variance of the bands eluting from them. The best performance was obtained with radially interconnected distributors with a diverging inlet section and filled with diamond-shaped pillars, oriented perpendicular to the main flow direction and with a high transversal over axial aspect ratio. It was found that the best distributor designs start with a diverging section containing some 10-12 subsequent rows of high aspect ratio pillars (with a transversal width making up 10-15% of the final channel width) and with a divergence angle selected such that the sloped side-walls run parallel with the sides of the diamond-shaped pillars. After this zone, one or more regions with pillars with a smaller aspect ratio should be provided to increase the number of exit points. To prevent the formation of dead zones in these subsequent zones, so-called distributor wedges can be used to prevent the formation of any dead zones in the wake of the large aspect ratio pillars of the preceding section.
引用
收藏
页码:467 / 477
页数:11
相关论文
共 50 条
  • [1] Dispersion control in pressure-driven flow through bowed rectangular microchannels
    Garam Lee
    Alan Luner
    Jeremy Marzuola
    Daniel M. Harris
    Microfluidics and Nanofluidics, 2021, 25
  • [2] Analytical solution of mixed electroosmotic and pressure-driven flow in rectangular microchannels
    Yang, Dayong
    MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 679 - 683
  • [3] Dispersion control in pressure-driven flow through bowed rectangular microchannels
    Lee, Garam
    Luner, Alan
    Marzuola, Jeremy
    Harris, Daniel M.
    MICROFLUIDICS AND NANOFLUIDICS, 2021, 25 (04)
  • [4] Numerical Modeling of Pressure-Driven Nitrogen Slip Flow in Long Rectangular Microchannels
    Sun, Zhanyu
    Jaluria, Yogesh
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2009, 56 (07) : 541 - 562
  • [5] Electrokinetic effects on pressure-driven liquid flows in rectangular microchannels
    Yang, C
    Li, DQ
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1997, 194 (01) : 95 - 107
  • [6] CFD-based Shape Optimization of Pressure-driven Microchannels
    Tonomura, Osamu
    Kano, Manabu
    Hasebe, Shinji
    DESIGN FOR ENERGY AND THE ENVIRONMENT, 2010, : 785 - 793
  • [7] H2 forced convection in rectangular microchannels under a mixed electroosmotic and pressure-driven flow
    Sadeghi, Arman
    Azari, Milad
    Chakraborty, Suman
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 122 : 162 - 171
  • [8] Pressure-driven flow of wormlike micellar solutions in rectilinear microchannels
    Cromer, Michael
    Cook, L. Pamela
    McKinley, Gareth H.
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2011, 166 (3-4) : 180 - 193
  • [9] Pressure-driven electrokinetic slip-flow in planar microchannels
    Jamaati, J.
    Niazmand, H.
    Renksizbulut, M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (07) : 1165 - 1174
  • [10] Flow near the meniscus of a pressure-driven water slug in microchannels
    Sungwook Kim
    Songwan Jin
    Jung Yul Yoo
    Journal of Mechanical Science and Technology, 2006, 20 : 710 - 716