An empirical study of the maximum degree of undersampling in compressed sensing for T2*-weighted MRI

被引:4
|
作者
Lazarus, Carole [1 ,2 ,3 ]
Weiss, Pierre [4 ,5 ]
Vignaud, Alexandre [1 ,2 ]
Ciuciu, Philippe [1 ,2 ,3 ]
机构
[1] CEA Saclay, NeuroSpin, F-91191 Gif Sur Yvette, France
[2] Univ Paris Saclay, St Aubin, France
[3] INRIA, Parietal, F-91120 Palaiseau, France
[4] CNRS, ITAV USR3505, F-31000 Toulouse, France
[5] CNRS, IMT UMR 5219, F-31400 Toulouse, France
关键词
Compressed sensing; MRI; Image quality; Maximum undersampling factor; ALGORITHM; RECONSTRUCTION;
D O I
10.1016/j.mri.2018.07.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance Imaging (MRI) is one of the most dynamic and safe imaging modalities used in clinical routine today. Yet, one major limitation to this technique resides in its long acquisition times. Over the last decade, Compressed Sensing (CS) has been increasingly used to address this issue and offers to shorten MR scans by reconstructing images from undersampled Fourier data. Nevertheless, a quantitative guide on the degree of acceleration applicable to a given acquisition scenario is still lacking today, leading in practice to a trial-and-error approach in the selection of the appropriate undersampling factor. In this study, we shortly point out the existing theoretical sampling results in CS and their limitations which motivate the focus of this work: an empirical and quantitative analysis of the maximum degree of undersampling allowed by CS in the specific context of T-2*-weighted MRI. We make use of a generic method based on retrospective undersampling to quantitatively deduce the maximum acceleration factor R-max which preserves a desired image quality as a function of the image resolution and the available signal-to-noise ratio (SNR). Our results quantify how larger acceleration factors can be applied to higher resolution images as long as a minimum SNR is guaranteed. In practice however, the maximum acceleration factor for a given resolution appears to be constrained by the available SNR inherent to the considered acquisition. Our analysis enables to take this a priori knowledge into account, allowing to derive a sequence-specific maximum acceleration factor adapted to the intrinsic SNR of any MR pipeline. These results obtained on an analytical T-2*-weighted phantom image were corroborated by prospective experiments performed on MR data collected with radial trajectories on a 7 T scanner with the same contrast. The proposed framework allows to study other sequence weightings and therefore better optimize sequences when accelerated using CS.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 50 条
  • [1] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [2] The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI
    Chan, Rachel W.
    Ramsay, Elizabeth A.
    Cheung, Edward Y.
    Plewes, Donald B.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 363 - 377
  • [3] T2*-weighted MRI in cortical venous thrombosis
    Cakmak, S
    Hermier, M
    Montavont, A
    Derex, L
    Mauguière, F
    Trouillas, P
    Nighoghossian, N
    NEUROLOGY, 2004, 63 (09) : 1698 - 1698
  • [4] Imaging the ischaemic penumbra with T2* weighted MRI
    McCabe, Christopher
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (02): : 281 - 282
  • [5] T2*-Weighted MRI Findings of Superficial Siderosis
    Yamamoto, Yu
    Yamamoto, Sayaka
    Kuroki, Shigehiro
    INTERNAL MEDICINE, 2012, 51 (14) : 1949 - 1949
  • [6] Accelerated Simultaneous T2 and T2* Mapping of Multiple Sclerosis Lesions Using Compressed Sensing Reconstruction of Radial RARE-EPI MRI
    Herrmann, Carl J. J.
    Starke, Ludger
    Millward, Jason M.
    Kuchling, Joseph
    Paul, Friedemann
    Niendorf, Thoralf
    TOMOGRAPHY, 2023, 9 (01) : 299 - 314
  • [7] Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction
    Hollingsworth, Kieren Grant
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : R297 - R322
  • [8] T2*weighted fetal MRI and the correlation with placental dysfunction
    Baadsgaard, Kirstine
    Hansen, Ditte N.
    Peters, David A.
    Frokjaer, Jens B.
    Sinding, Marianne
    Sorensen, Anne
    PLACENTA, 2023, 131 : 90 - 97
  • [9] Fast T2*-Weighted MRI of the Prostate at 3 Tesla
    Hardman, Rulon L.
    El-Merhi, Fadi
    Jung, Adam J.
    Ware, Steve
    Thompson, Ian M.
    Friel, Harry T.
    Peng, Qi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 902 - 907
  • [10] GRE T2*-Weighted MRI: Principles and Clinical Applications
    Tang, Meng Yue
    Chen, Tian Wu
    Zhang, Xiao Ming
    Huang, Xiao Hua
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014