Experimental study on safe performance of nozzle-type electrostatic neutralizer

被引:2
|
作者
Choi, KS
Yamaguma, M
Kodama, T
Suzuki, T
Mogami, T
机构
[1] Natl Inst Ind Safety, Independent Adm Inst, Tokyo 2040024, Japan
[2] Kasuga Denki Inc, Ota Ku, Tokyo 1440031, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS | 2005年 / 44卷 / 28-32期
关键词
electrostatic neutralizer; incendiary discharge; ignitability; powder;
D O I
10.1143/JJAP.44.L1026
中图分类号
O59 [应用物理学];
学科分类号
摘要
The safe performance of a nozzle-type electrostatic neutralizer was examined experimentally in inflammable gas (ethylene)air mixtures. A 100M Omega-coupled electrode produced ion pairs safely for reducing static charges from polymer materials, and incendiary discharges were suppressed by the resistor and voltage supplied to the electrode. The performance of the neutralizer (flange-type) driven with an AC (50Hz) or DC high-voltage power source was also evaluated witha full-size pneumatic powder-transport system. It was confirmed that the nozzle-type neutralizer is markedly effective for reducing electrostatic charges from polymer materials; however, several disadvantages were also noted.
引用
收藏
页码:L1026 / L1029
页数:4
相关论文
共 50 条
  • [1] NOZZLE-TYPE APPLICATORS
    不详
    VERPACKUNGS RUNDSCHAU, 1978, 29 (05): : 700 - &
  • [2] PERFORMANCE OF NOZZLE-TYPE WELDED-JOINTS
    VORNOVIT.IN
    RAZUMOVA, ED
    YAKOBSON, SS
    WELDING PRODUCTION, 1974, 21 (02): : 49 - 52
  • [3] PERFORMANCE OF NOZZLE-TYPE WELDED JOINTS.
    Vornovitskii, I.N.
    Orgenergostroi Inst, USSR
    Razumova, E.D.
    Yakobson, S.S.
    Welding Production (English translation of Svarochnoe Proizvodstvo), 1974, 21 (02): : 49 - 52
  • [4] Experimental study on improving heat transfer performance of multi-parallel evaporators with improved rectifier nozzle-type distributor
    Sun, Zhili
    Zhao, Haiwang
    Wang, Qifan
    Hou, Fumin
    Zhang, Wenfu
    Wang, Dandan
    APPLIED THERMAL ENGINEERING, 2025, 260
  • [5] Experimental study on the shunting performance of a rectifying nozzle-type critical distributor under variable operating conditions of a multiparallel evaporator
    Sun, Zhili
    Liang, Di
    Cheng, Wanfei
    Liang, Youcai
    Lou, Lin
    Jin, Hui
    Zhang, Chao
    Wang, Yian
    Si, Chunqiang
    Liu, Shengchun
    Gao, Enyuan
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [6] An experimental and analytical study to analyze hydraulic behavior of nozzle-type underdrains in porous media filters
    Arbat, G.
    Pujol, T.
    Puig-Bargues, J.
    Duran-Ros, M.
    Montoro, L.
    Barragan, J.
    Ramirez de Cartagena, F.
    AGRICULTURAL WATER MANAGEMENT, 2013, 126 : 64 - 74
  • [7] Design and performance of a nozzle-type rainfall simulator for landslide triggering experiments
    Lora, Marco
    Camporese, Matteo
    Salandin, Paolo
    CATENA, 2016, 140 : 77 - 89
  • [8] Evaluation of an indoor nozzle-type rainfall simulator
    Birt, L. N.
    Persyn, R. A.
    Smith, P. K.
    APPLIED ENGINEERING IN AGRICULTURE, 2007, 23 (03) : 283 - 287
  • [9] Calibration of an oscillating nozzle-type rainfall simulator
    Yu, B
    Ciesiolka, CAA
    Langford, P
    EARTH SURFACE PROCESSES AND LANDFORMS, 2003, 28 (13) : 1483 - 1490
  • [10] CHARACTERISTICS OF NOZZLE-TYPE HYDRAULIC THROTTLE VALVES
    BEKIROV, YA
    RUSSIAN ENGINEERING JOURNAL-USSR, 1968, 48 (12): : 42 - &