The influence of particle statistics of a tetracalcium aluminoferrite (C(4)AF)-aluminium oxide (Al2O3) mixture on the accuracy of X-ray quantitative analysis was investigated by the reference intensity ratio (RIR) and the Rietveld method, supported by two-dimensional synchrotron diffraction image and integral one-dimensional diffraction pattern as a standard control. The quantitative results of tetracalcium aluminoferrite-aluminium oxide mixture show that both the RIR and Rietveld method can perform correctly quantitative analysis when most of the particles (>95%) have sizes in the range between 1 and 5 mu m. The actual particle size distribution is between 0.7 mu m and 5.1 mu m. The amorphous rate of tetracalcium aluminoferrite is 2.8% during such grinding processes. The errors increase dramatically if large particles of tetracalcium aluminoferrite (>5 mu m) exist, even though such particles are as low as 3.2% in numerical statistics.