An efficient method for measuring the parameters of single-mode anisotropic slab waveguides using the prism-coupling technique

被引:1
|
作者
Gao, FB [1 ]
Du, GT
Vannadeth
Zhang, P
Lun, F
机构
[1] Jilin Univ, Coll Elect Sci & Engn, State Key Lab Integrated Optoelect, Changchun 130012, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
关键词
anisotropic slab waveguide; prism coupling technique; measurement;
D O I
10.1002/mop.21234
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An efficient method for measuring the parameters of anisotropic slab waveguides is presented in this paper. This method can be used to measure the parameters of single-mode anisotropic slab waveguides. The measured results show that the errors of the refractive indices are within 4.2 x 10(-4). (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:575 / 580
页数:6
相关论文
共 31 条