New approach for T-wave end detection on electrocardiogram: Performance in noisy conditions

被引:62
|
作者
Vazquez-Seisdedos, Carlos R. [2 ]
Neto, Joao Evangelista [1 ,3 ,4 ]
Maranon Reyes, Enrique J. [2 ]
Klautau, Aldebaro [1 ]
Limao de Oliveira, Roberto C. [1 ]
机构
[1] Fed Univ Para, Fac Elect Engn, BR-66059 Belem, Para, Brazil
[2] Univ Oriente, Fac Elect Engn, Ctr Studies Neurosci & Images & Signals Proc CENP, Santiago De Cuba, Cuba
[3] Univ Paulista, Manaus, Amazonas, Brazil
[4] State Univ Amazonas, Fac Elect Engn, Manaus, Amazonas, Brazil
来源
关键词
QRS DETECTION; HOLTER ECG; QT; ALGORITHMS; INTERVALS; DATABASE;
D O I
10.1186/1475-925X-10-77
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The detection of T-wave end points on electrocardiogram (ECG) is a basic procedure for ECG processing and analysis. Several methods have been proposed and tested, featuring high accuracy and percentages of correct detection. Nevertheless, their performance in noisy conditions remains an open problem. Methods: A new approach and algorithm for T-wave end location based on the computation of Trapezium's areas is proposed and validated (in terms of accuracy and repeatability), using signals from the Physionet QT Database. The performance of the proposed algorithm in noisy conditions has been tested and compared with one of the most used approaches for estimating the T-wave end point: the method based on the threshold on the first derivative. Results: The results indicated that the proposed approach based on Trapezium's areas outperformed the baseline method with respect to accuracy and repeatability. Also, the proposed method is more robust to wideband noise. Conclusions: The trapezium-based approach has a good performance in noisy conditions and does not rely on any empirical threshold. It is very adequate for use in scenarios where the levels of broadband noise are significant.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] New approach for T-wave end detection on electrocardiogram: Performance in noisy conditions
    Carlos R Vázquez-Seisdedos
    João Evangelista Neto
    Enrique J Marañón Reyes
    Aldebaro Klautau
    Roberto C Limão de Oliveira
    BioMedical Engineering OnLine, 10
  • [2] Automatic detection of the electrocardiogram T-wave end
    Daskalov, IK
    Christov, II
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (03) : 348 - 353
  • [3] Automatic detection of the electrocardiogram T-wave end
    I. K. Daskalov
    I. I. Christov
    Medical & Biological Engineering & Computing, 1999, 37 : 348 - 353
  • [4] INTERPRETATION OF T-WAVE OF ELECTROCARDIOGRAM
    NOBLE, D
    COHEN, I
    CARDIOVASCULAR RESEARCH, 1978, 12 (01) : 13 - 27
  • [5] Neural Network Approach for T-wave End Detection: A Comparison of Architectures
    Suarez Leon, Alexander A.
    Matos Molina, Danelia
    Vazquez Seisdedos, Carlos R.
    Goovaerts, Griet
    Vandeput, Steven
    Van Huffel, Sabine
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 589 - 592
  • [6] New approach for T-wave peak detection and T-wave end location in 12-lead paced ECG signals based on a mathematical model
    Madeiro, Joao P. V.
    Nicolson, William B.
    Cortez, Paulo C.
    Marques, Joao A. L.
    Vazquez-Seisdedos, Carlos R.
    Elangovan, Narmadha
    Ng, G. Andre
    Schlindwein, Fernando S.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (08) : 1105 - 1115
  • [7] Article on the importance of T-wave of electrocardiogram
    Garten, S
    Sulze, W
    ZEITSCHRIFT FUR BIOLOGIE, 1916, 66 (10/11): : 433 - 478
  • [8] EXPERIMENTAL VARIATIONS IN THE T-WAVE OF THE ELECTROCARDIOGRAM
    SJOSTRAND, T
    ACTA MEDICA SCANDINAVICA, 1950, 138 (03): : 191 - 200
  • [9] CAUSATION OF THE T-WAVE IN THE HUMAN ELECTROCARDIOGRAM
    CRAIB, WH
    SOUTH AFRICAN MEDICAL JOURNAL, 1979, 55 (07): : 233 - 234
  • [10] Automatic Detection of T-wave End in ECG Signals
    Shuo, Yang
    Desong, Bian
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, VOL III, PROCEEDINGS, 2008, : 283 - +