Novel iron (III) phthalocyanine derivative functionalized semiconductor based transducers for the detection of citrate

被引:21
|
作者
Azzouzi, Sawsen [1 ]
Ben Ali, Mounir [1 ]
Abbas, Mohammed Nooredeen [2 ]
Bausells, Joan [3 ]
Zine, Nadia [4 ]
Errachid, Abdelhamid [4 ]
机构
[1] Univ Sousse, Higher Inst Appl Sci & Technol Sousse, GREENS ISSAT, Cite Ettafala, Sousse 4003, Tunisia
[2] Natl Res Ctr, Dept Appl Organ Chem, Analyt Lab, Cairo, Egypt
[3] IMB CNM CSIC, Inst Microelect Barcelona, Bellaterra 08193, Spain
[4] Univ Lyon 1, ISA, UMR 5280, F-69100 Villeurbanne, France
关键词
Citrate selective ionophore; Capacitance voltage measurements; ISFET; Potentiometry; Prostate cancer; NANOTUBE PASTE ELECTRODE; INJECTION SPECTROPHOTOMETRIC DETERMINATION; METAL-ION DETECTION; CITRIC-ACID; PROSTATE-CANCER; FLOW-INJECTION; FOLIC-ACID; VOLTAMMETRIC DETERMINATION; POTENTIOMETRIC DETECTION; ELECTROCATALYTIC OXIDATION;
D O I
10.1016/j.orgel.2016.04.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present work, we report a novel citrate-selective sensor based on iron (III) phthalocyanine chloride-C-monoamido-Poly-n-Butyl Acrylate (Fe(III) MAPcCl-P-n-BA) modified silicon nitride and Ion sensitive field effect transistor (ISFET) structures for the electrochemical determination and estimation of the pathophysiological range of citrate. The developed capacitive sensor based on Fe(III) MAPcCl-P-n-BA had a Nernstian sensitivity of (-20.2 +/- 1.3) mV/decade with a detection limit of about 7 x 10(-7) M and a linear range from 10(-6) M to 10(-1) M (RSD = 6.2%). Then, the performance of the Fe(III)MAPcCl-P-n-BA functionalized ISFET structure towards the detection of citrate has been investigated. A Nernstian sensitivity of about (-19.8 +/- 1.0) mV/decade in the range from 10(-6) M to 10(-1) M was achieved (RSD = 4.8%) which covered the pathologically important clinical range of citrate. The detection limit was about 4 x 10(-7) M. The number of available recognition sites N-s and the complexation constant pK were calculated using the enhanced site binding model. A side by side comparison of the developed chemical sensors based on electrolyte-insulator-Semi conductor (EIS) and ISFET structures showed similar characteristics which proves the successful miniaturization of the semiconductor based transducer. The obtained experimental data of the Fe(III) MAPcCl-P-n-BA functionalized ISFET structure were used to validate the TopSPICE ISFET/MEMFET macromodel. The obtained theoretical sensitivity was in good agreement to the experimental one which proves the successful design of the developed ISFET/MEMFET macromodel. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 215
页数:8
相关论文
共 50 条
  • [1] Novel Sensitive Impedimetric Microsensor for Phosphate Detection Based on a Novel Copper Phthalocyanine Derivative
    Zina, Fredj
    Nooredeen, Naglaa M.
    Azzouzi, Sawsen
    Ben Ali, Mounir
    Abbas, Mohammed Nooredeen
    Errachid, Abdelhamid
    ANALYTICAL LETTERS, 2018, 51 (03) : 371 - 386
  • [2] Novel Fluorescent Chemosensor for Detection of F- Anions Based on a Single Functionalized Pillar[5]arene Iron(III) Complex
    Zhang, Youming
    Su, Junxia
    Li, Qiao
    Li, Wenting
    Liang, Guoyan
    Li, Hui
    Ma, Haixia
    Lin, Qi
    Yao, Hong
    Wei, Taibao
    CHINESE JOURNAL OF CHEMISTRY, 2016, 34 (12) : 1263 - 1267
  • [3] Novel Functionalized Pyridoindole Derivatives Catalyzed by Iron(III) Triflate
    Damavandi, Saman
    Sandaroos, Reza
    SYNTHESIS AND REACTIVITY IN INORGANIC METAL-ORGANIC AND NANO-METAL CHEMISTRY, 2015, 45 (11) : 1660 - 1663
  • [4] Polyamine-functionalized carbon nanodots: a novel chemiluminescence probe for selective detection of iron(III) ions
    Zhao, Lixia
    Geng, Fanglan
    Di, Fan
    Guo, Liang-Hong
    Wan, Bin
    Yang, Yu
    Zhang, Hui
    Sun, Guozhu
    RSC ADVANCES, 2014, 4 (86): : 45768 - 45771
  • [5] Evaluation of a novel composite based on functionalized multi-walled carbon nanotube and iron phthalocyanine for electroanalytical determination of isoniazid
    Rolff Ferreira Spindola
    Hudson Zanin
    Cleidivan Silva Macena
    André Contin
    Rita de Cássia Silva Luz
    Flávio Santos Damos
    Journal of Solid State Electrochemistry, 2017, 21 : 1089 - 1099
  • [6] Evaluation of a novel composite based on functionalized multi-walled carbon nanotube and iron phthalocyanine for electroanalytical determination of isoniazid
    Spindola, Rolff Ferreira
    Zanin, Hudson
    Macena, Cleidivan Silva
    Contin, Andre
    Silva Luz, Rita de Cassia
    Damos, Flavio Santos
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2017, 21 (04) : 1089 - 1099
  • [7] Synthesis and photophysical properties of a novel ethynyl zinc(II) phthalocyanine and its functionalized derivative with click chemistry
    Sevim, Altug Mert
    Ozcesmeci, Ibrahim
    Gul, Ahmet
    JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2013, 17 (6-7) : 540 - 547
  • [8] Novel spectrofluorimetric method for the determination of thiamine with iron(III)-tetrasulfonato-phthalocyanine as a catalyst
    Chen, Qiu-Ying
    Li, Dong-Hui
    Yang, Huang-Hao
    Zheng, Hong
    Zhu, Chang-Qing
    Xu, Jin-Gou
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 1999, 20 (5 Suppl):
  • [9] Colorimetric Determination of Al(III) Based on the Aggregation of Gold Nanoparticles Functionalized with Novel 4-Benzoyl Pyrazolone Derivative
    Abubaker, Mariam
    Ngah, Che Wan Zanariah Che Wan
    Ahmad, Musa
    Kuswandi, Bambang
    RECENT ADVANCEMENT ON APPLIED PHYSICS, INDUSTRIAL CHEMISTRY AND CHEMICAL TECHNOLOGY, 2018, 1972
  • [10] Novel porous iron phthalocyanine based metal-organic framework electrochemical sensor for sensitive vanillin detection
    Peng, Jinyun
    Wei, Liying
    Liu, Yuxia
    Zhuge, Wenfeng
    Huang, Qing
    Huang, Wei
    Xiang, Gang
    Zhang, Cuizhong
    RSC ADVANCES, 2020, 10 (60) : 36828 - 36835