Multimodal Chemical Analysis of the Brain by High Mass Resolution Mass Spectrometry and Infrared Spectroscopic Imaging

被引:48
|
作者
Neumann, Elizabeth K. [1 ,2 ]
Comi, Troy J. [2 ,3 ]
Spegazzini, Nicolas [2 ,3 ]
Mitchell, Jennifer W. [2 ,4 ,5 ]
Rubakhin, Stanislav S. [1 ,2 ,5 ]
Gillette, Martha U. [2 ,3 ,4 ,5 ]
Bhargava, Rohit [1 ,2 ,3 ]
Sweedler, Jonathan, V [1 ,2 ,3 ,5 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61820 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61820 USA
[3] Univ Illinois, Dept Bioengn, Urbana, IL 61820 USA
[4] Univ Illinois, Dept Cell & Dev Biol, Urbana, IL 61820 USA
[5] Univ Illinois, Neurosci Program, Urbana, IL 61820 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
DENTATE GYRUS; RAT-BRAIN; MALDI-MS; MOLECULAR ANALYSIS; TISSUE-SECTIONS; FT-IR; CELLS; MEMORY; RAMAN; MICROSPECTROSCOPY;
D O I
10.1021/acs.analchem.8b02913
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The brain functions through chemical interactions between many different cell types, including neurons and glia. Acquiring comprehensive information on complex, heterogeneous systems requires multiple analytical tools, each of which have unique chemical specificity and spatial resolution. Multimodal imaging generates complementary chemical information via spatially localized molecular maps, ideally from the same sample, but requires method enhancements that span from data acquisition to interpretation. We devised a protocol for performing matrix-assisted laser desorption/ionization (MALDI)-Fourier transform ion cyclotron resonance-mass spectrometry imaging (MSI), followed by infrared (IR) spectroscopic imaging on the same specimen. Multimodal measurements from the same tissue provide precise spatial alignment between modalities, enabling more advanced image processing such as image fusion and sharpening. Performing MSI first produces higher quality data from each technique compared to performing IR imaging before MSI. The difference is likely due to fixing the tissue section during MALDI matrix removal, thereby preventing analyte degradation occurring during IR imaging from an unfixed specimen. Leveraging the unique capabilities of each modality, we utilized pan sharpening of MS (mass spectrometry) ion images with selected bands from IR spectroscopy and midlevel data fusion. In comparison to sharpening with histological images, pan sharpening can employ a plethora of IR bands, producing sharpened MS images while retaining the fidelity of the initial ion images. Using Laplacian pyramid sharpening, we determine the localization of several lipids present within the hippocampus with high mass accuracy at 5 mu m pixel widths. Further, through midlevel data fusion of the imaging data sets combined with k-means clustering, the combined data set discriminates between additional anatomical structures unrecognized by the individual imaging approaches. Significant differences between molecular ion abundances are detected between relevant structures within the hippocampus, such as the CA1 and CA3 regions. Our methodology provides high quality multiplex and multimodal chemical imaging of the same tissue sample, enabling more advanced data processing and analysis routines.
引用
收藏
页码:11572 / 11580
页数:9
相关论文
共 50 条
  • [1] Chemical analysis of the human brain by imaging mass spectrometry
    Ajith, Akhila
    Sthanikam, Yeswanth
    Banerjee, Shibdas
    ANALYST, 2021, 146 (18) : 5451 - 5473
  • [2] Mass spectrometry imaging with high resolution in mass and space
    Andreas Römpp
    Bernhard Spengler
    Histochemistry and Cell Biology, 2013, 139 : 759 - 783
  • [3] Mass spectrometry imaging with high resolution in mass and space
    Roempp, Andreas
    Spengler, Bernhard
    HISTOCHEMISTRY AND CELL BIOLOGY, 2013, 139 (06) : 759 - 783
  • [4] Mass microscopy: high-resolution imaging mass spectrometry
    Setou, Mitsutoshi
    Kurabe, Nobuya
    JOURNAL OF ELECTRON MICROSCOPY, 2011, 60 (01): : 47 - 56
  • [5] Mass Spectrometry and High Resolution Mass Spectrometry: An Overview
    Giorgi, Gianluca
    MOLECULAR TECHNOLOGIES FOR DETECTION OF CHEMICAL AND BIOLOGICAL AGENTS, 2017, : 89 - 101
  • [6] Molecular histology with high resolution imaging mass spectrometry
    Kellersberger, Katherine
    Kowalski, Jane-Marie
    Becker, Michael
    Deininger, Soeren-Oliver
    Cornett, Shannon
    FASEB JOURNAL, 2013, 27
  • [7] Analysis of chemical contaminants in fish using high resolution mass spectrometry - A review
    Turnipseed, Sherri B.
    TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024, 42
  • [8] Multimodal Image Fusion Offers Better Spatial Resolution for Mass Spectrometry Imaging
    Guo, Lei
    Zhu, Jinyu
    Wang, Keqi
    Cheng, Kian-Kai
    Xu, Jingjing
    Dong, Liheng
    Xu, Xiangnan
    Chen, Can
    Shah, Mudassir
    Peng, Zhangxiao
    Wang, Jianing
    Cai, Zongwei
    Dong, Jiyang
    ANALYTICAL CHEMISTRY, 2023, 95 (25) : 9714 - 9721
  • [9] MIXTURE ANALYSIS BY HIGH-RESOLUTION MASS-SPECTROMETRY MASS-SPECTROMETRY
    RUSSELL, DH
    MCBAY, EH
    MUELLER, TR
    INTERNATIONAL LABORATORY, 1980, 10 (03): : 49 - &
  • [10] MIXTURE ANALYSIS BY HIGH-RESOLUTION MASS-SPECTROMETRY MASS-SPECTROMETRY
    RUSSELL, DH
    MCBAY, EH
    MUELLER, TR
    AMERICAN LABORATORY, 1980, 12 (03) : 50 - &